Se Byeong Lee, Ph.D Chief Medical Physicist Proton Therapy Center in NCC, Korea.

Slides:



Advertisements
Similar presentations
Monte Carlo Based Implementation of an Energy Modulation System for Proton Therapy G.A.P. Cirrone Qualified Medical Physicist PhD Laboratori Nazionali.
Advertisements

The Vin č a Institute of Nuclear Sciences, Belgrade, Serbia * Universita degli studi di Bologna, DIENCA, Italia Radovan D. Ili}, Milan Pe{i}, Radojko Pavlovi}
14th GEANT4 User and Collaboration Workshop - Catania, Oct. 15/ B.Caccia, G.Frustagli, M.Mattia, S.Valentini Istituto Superiore di Sanita' e INFN,
Advanced GAmma Tracking Array
Use of G EANT 4 in CMS AIHENP’99 Crete, April 1999 Véronique Lefébure CERN EP/CMC.
GEANT4 simulation of an ocular proton beam & benchmark against MC codes D. R. Shipley, H. Palmans, C. Baker, A. Kacperek Monte Carlo 2005 Topical Meeting.
Faiza Bourhaleb Dipartimento di fisica sperimentale
LCSC - 01 Monte Carlo Simulation of Radiation Transport, for Stereotactic Radio Surgery Per Kjäll Elekta Instrument AB
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
FREDONE, A PROJECT ON DOSIMETRY OF HIGH ENERGY NEUTRONS Valérie De Smet (1), Isabelle Gerardy (2), Fréderic Stichelbaut (3), (1) IRISIB, Département nucléaire,
Experience, Expertise and a Commitment to Excellence™
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
MONTE-CARLO TECHNIQUES APPLIED TO PROTON DOSIMETRY AND RADIATION SAFETY F. Guillaume, G. Rucka, J. Hérault, N. Iborra, P. Chauvel 1 XXXV European Cyclotron.
Building clinical Monte Carlo code from Geant4, PENELOPE or EGSnrc Joao Seco 1, Christina Jarlskog 1, Hongyu Jiang 2 and Harald Paganetti 1 1 Francis H.
Hadronic and Electromagnetic Physics: special applications V.Ivanchenko BINP, Novosibirsk, Russia & CERN, Geneve, Switzerland.
G4NAMU meeting March 6th, 2006 Validation Activities at SLAC of Relevance to Medical Users Koi, Tatsumi SLAC/SCCS.
Geant4 in Brachytherapy
G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti.
Tissue inhomogeneities in Monte Carlo treatment planning for proton therapy L. Beaulieu 1, M. Bazalova 2,3, C. Furstoss 4, F. Verhaegen 2,5 (1) Centre.
14 User Documents and Examples II SLAC Geant4 Tutorial 17 May 2007 Dennis Wright Geant4 V8.3.
The brachytherapy advanced example Susanna Guatelli (CERN/INFN)
Budker Inst. of Physics IHEP Protvino MEPHI Moscow Pittsburg University.
Med-1 Protontherapy and microdosimetry with the Geant4 toolkit
SOI detector Geant4-based studies to characterise the tissue-equivalence of SOI and diamond microdosimeteric detectors, under development at CMRP S. Dowdell,
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Joseph Perl SLAC National Accelerator Laboratory Scientific Computing Workshop 20 June 2011 Work supported in part by the U.S. Department of Energy under.
Ian C. Smith 1 A portal-based system for quality assurance of radiotherapy treatment plans using Grid-enabled High Performance Computing clusters CR Baker.
1 Dr. Sandro Sandri (President of Italian Association of Radiation Protection, AIRP) Head, Radiation Protection Laboratory, IRP FUAC Frascati ENEA – Radiation.
Gamma Ray Imaging Lab Tour
A General Purpose Brachytherapy Software Simulation + Analysis (isodose calculation) 2/10/2002 Geant4 Workshop CERN Susanna Guatelli Univ. and INFN Genova.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Geant4 based simulation of radiotherapy in CUDA
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
Araki F. Ikegami T. and Ishidoya T.
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
IRCC & Mauriziano Hospital & INFN & S Croce e Carle Hospital
Shielding Measurements For A Proton Therapy Facility S. Avery, K. P. Risolo, M. Bartels, C. Ainsley, J McDonough, R. L. Maughan University of Pennsylvania.
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
Geant4 Activities in Japan Some news from Takashi Sasaki, Koichi Murakami, Akinori Kimura and colleagues.
8/Mar./041st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application 1 Use-Case on treatment planning at HIMAC Koichi Murakami KEK 1 st.
Comparison of MC and TP Dosimetry Simulations for Cancer Treatment Raymond Mumme May 12, 2014 Supervisor: Thiago Lima (PhD student) Head Supervisor: Dr.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
ESTRO, Geneva 2003 The importance of nuclear interactions for dose calculations in proton therapy M.Soukup 1, M.Fippel 2, F. Nuesslin 2 1 Department of.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
GATE application example using SuperComputer 국립암센터 박 세 준 연구원.
한양대학교 원자력공학과 김 찬 형 제44회 춘계의학물리학회 & Geant4 Workshop (충무, 마리나 리조트, ) Monte Carlo 원리 및 응용.
Geant4 Simulation Study for Proton Therapy Proton Therapy Center Se Byeong Lee Medical Physicist, Ph.D. The 3 rd FKPPL workshop, March 8-9, 2011, Seoul,
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Medical application of proton accelerators
Koichi MurakamiGeant4 Physics Verification and Validation (17-19/Jul./2006) 1 Results from the recent carbon test beam at HIMAC Koichi Murakami Statoru.
MCS overview in radiation therapy
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Geant4 for (Medical) Education “ Geant4 for (Medical) Education ” Toolkit and Courseware Geant4 Medical Workshop in Lyon 21 July 2006 Universite-Lyon I.
Achim Stahl RWTH Aachen Hadron Therapy, Jülich Oct, Workshop Nuclear Models for Use in Hadron Therapy October 8./ Achim Stahl – RWTH Aachen.
INTERCOMPARISON P3. Dose distribution of a proton beam
Very High Energy Electron for Radiotherapy Studies
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
Introduction Goal: Can we reconstruct the energy depositions of the proton in the brain if we are able to reconstruct the photons produced during this.
Geant4 physics validation: Bragg Peak
The Hadrontherapy Geant4 advanced example
GEANT Simulations and Track Reconstruction
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
The Geant4 Hadrontherapy Advanced Example
Presentation transcript:

Se Byeong Lee, Ph.D Chief Medical Physicist Proton Therapy Center in NCC, Korea

Proton Treatment Planning : Accurate dose calculation ? Radiation Shielding : Patient & worker safety ? Patient simulation (Respiratory gating) : 4D Dose distribution ? Beam Nozzle simulation : Design study, QA ?  Monte Carlo Simulation

Target Ex.) 5mm beam off on Target (1 portal) - Proton : 100%  0% dose - Photon : 100%  > 95% dose

MGH study

Proton beam facility in NCC Proton beam facility in NCC Proteus 235 Specification Weight : 220 ton Height : 210 cm Diameter : 434 cm Energy : 230MeV Max. extracted beam current : 300nA RF frequency :106 MHz

1. Modeling  Modeling Nozzle  Modeling Treatment scheme 2. User interface for M.C set-up  Convalgo (“Conversion Algorithm” by IBA) interface 3. Validation  Geant4 physics test on CSDA range and non-elastic interaction probability  Bragg peaks comparison  Conversion function (Range2MCEnergy) 4. Applications  SOBP reproduction for Proton therapy

Scanning Magnet 1 st Ion Chamber 1 st Scatterer 2 nd Scatterer Range Modulator Variable Collimator SnoutSnout 2 nd & 3 rd Ion Chamber Aperture & Compensator Compensator

Passive mode Dynamic mode

Geant4 version: 8.2.p01 - EM model : G4hIonization with ICRU49 parameterized table - Hadronic : LHEP_PRECO_HP ( precompound model ) NCC Proton Beam Delivery MC Simulation MC Simulation validation Test

15 X 15 Voxelized Water Phantom

Milling machineRTPG EANT 4

 Patient geometry ◦ Patient scanned data from CT in DICOM format ◦ Each CT is assigned to a voxel ◦ 3D Reformation / 2D Clustering of voxels ◦ HU – Material Table

CT Scanner CT Data Set G EANT 4 Geometry GDD Data

 In order to display the G EANT 4 output ◦ Volume data (including overlay of more than one set) ◦ Trajectories ◦ Geometry  Runs on: ◦ Windows, Linux and Mac ◦ Based on a commercial package but offered freely to all G EANT 4 users  Download ◦

 Developed based on DICOM-pyler  Written in python language  Function ◦ Visualize CT data set and simulated geometry ◦ Dose distribution ◦ Analysis and comparison of dose distribution

TPS MC Doss diff. Gamma Index  Plan Evaluation  Dose Difference  Gamma Index  Dose Volume Histogram  Plan Evaluation  Dose Difference  Gamma Index  Dose Volume Histogram TPS MC  Plan Evaluation  Dose Difference  Dose Volume Histogram  Gamma Index  Plan Evaluation  Dose Difference  Dose Volume Histogram  Gamma Index  Plan Evaluation  Dose Differencce  Dose Volume Histogram  Gamma Index  Plan Evaluation  Dose Differencce  Dose Volume Histogram  Gamma Index

 Proton Beam Dosimetry ◦ Scintillator-CCD system development ◦ Glass dosimetry ◦ Gold Maker for Patient Setup  Radiation Safety ◦ Secondary Neutron dose evaluation  Patient Treatment Planning ◦ Dose Calculation Accuracy of Commercial PTS ◦ Geant4-DNA

4  Beam mode modeling  DICOM data handling  Dose calculation using Geant4 MC simulation  Radiobiology Modeling Example of NCC study Example of NCC study

24  The capability of Geant4-DNA physics component can be complemented by advanced geometry modelling  DNA model inspired by M. A. Bernal and J. A. Liendo, Med. Phys., vol. 36, pp , 2009  Geant4 DNA model by S. Incerti 500 keV He +  Geant4 can predict number of SSBs and DSBs generated by direct effects of ionising radiation

 Able to model 5 physical interaction processes ◦ Single ionisation (p, H) ◦ Single capture (p) ◦ Double ionisation (p) ◦ Ionisation transfer (p) ◦ Stripping (H)  Applicable to protons and neutral hydrogen  Covering the energy range 10 keV – 1 MeV  Materials include ◦ Liquid water ◦ DNA nucleobases: Adenine, Thymine, Cytosine and Guanine  Their implementation started at CENBG during Spring and the venue of Jae Ik Shin ◦ Computation of total cross sections ◦ Computation of final state

 These cross section models will be combined with a geometrical model of a cellular nucleus including DNA structures, containing ◦ Either pure liquid water ◦ or liquid water and DNA material (A-T-G-C)  These models have been developed by Mr J. I. Shin in NCC ◦ Nucleotides ◦ Nucleosomes ◦ Chromatin fiber

Liquid waterAdenine One order of magnitude difference for dominant processes (SI, SC) Two orders of magnitude for DI preliminary

by J.I.Shin(NCC) Nucleotides Nucleosomes Make simple geometry having ratio of ATGC materials preliminary

- Joint workshop with Korean Society of Medical Physics(KSMP) Program and KISTI Geant4 supporting Program - Apr. 14, 2012 / Tong Young, Korea ~ 100 participants.

Thank you! Current & Past Geant4 Researchers in NCC - Dr. Jungwook Shin UCSF (TOPAS Collaboration) - Mr. Dae Hyun Kim Catholic University of Korea - Mr. Sey-Joon Park NCC Korea - Mr. Jae Ik Shin NCC Korea - Etc.. Proton Therapy Center