Unstoppable productivity; Uncompromised MS/MS simplicity Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS/MS Unstoppable productivity; Uncompromised.

Slides:



Advertisements
Similar presentations
Water Testing 1 Water Testing: How we measure what you cant see 1 st Elmvale Water Festival August 4, 2007 Ray Clement Laboratory Services Branch, Ontario.
Advertisements

Forensic Drug Testing Part 2: GC/MS Confirmation
Instrumental Analysis
Agilent 6410 Triple Quad LC/MS Software
Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.
With Supersonic Molecular Beams Maya Kochman and Aviv Amirav
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Tracer Measurement by LC-MS
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
MRMPilot ™ Software © 2008 Applera Corporation and MDS Inc.
Laboratory requirements Dioxin Workshop, Leon Mexico Richard Turle Analysis and Air Quality Division Environmental Science and Technology Centre Environment.
Development of a TOF Version of the Desktop MiniSIMS Design & Applications A.J. Eccles, B. Cliff, C. Jones, N. Long, P. Vohralik Millbrook Instruments.
Introducing the LEO 1400 Series
Waters Corporation Connecting Data to Decisions John Swallow Principal Engineer Waters Data Products
Real-time PCR automated solution for food pathogen testing
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
Zlata D. Clarka, M. Laura Parnasb and Elizabeth L. Frankb
Application of HR-LC-MS in screening methods for pesticides in cereals
Wilkes University - CHM D Gas Chromatography (or 3D with MS Detector) A powerful separations tool for complex volatile mixtures of heat-stable samples.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Raul Garcia-Sanchez Research Investigator: Dr. Paul R. Mahaffy Code 699, NASA Goddard Space Flight Center Research Mentor: Dr. Prabhakar Misra Department.
Orbitrap Technology: New Frontiers in Pesticide Residue Analysis
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
Three years of experience with backflush and retention time locking on Agilent 7000B GC-MS/MS Hans Ragnar Norli Bioforsk, Plant Health and Plant Protection.
Quantitative Insulin Analysis Using Liquid Chromatography–Tandem Mass Spectrometry in a High- Throughput Clinical Laboratory Z. Chen, M.P. Caulfield, M.J.
7000A GC-QQQ Applications Pesticides in Foods (3).
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
Sales Objections and FAQs 920-LC Analytical Systems.
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
7000A GC-QQQ Applications Pesticides in Foods (1).
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Automating Drug Metabolism Studies
Mass Spectrometry Quantitative Mass Spectrometry
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Hiden HPR-20 QIC EGA for evolved gas analysis in TGA-MS.
Toxicological Screening of 80 Drugs in Urine Using the High Resolution Exactive LC/MS Orbitrap Mass Spectrometer Coupled to Online Extraction and Turbulent.
Workflows to set up acquisition methods for scheduled sMRM-HR on the TripleTOF 5600 Start from a data dependent acquisition (DDA) Perform data base search.
What Bottlenecks are Slowing Down Your Lab? Software Solutions for Environmental Testing Charles Yang Strategic Marketing Manager Environmental Testing.
DIA Method Design, Data Acquisition, and Assessment
Thermo Scientific GC and GC-MS Systems
Introduction to Liquid Phase Mass Spectrometry
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Multi-Analyte LC-MS/MS Methods – Best Practice.
An integrated GC-MS workflow solution for the determination of (semi)volatiles in drinking water and solid waste according to the U.S. EPA guidelines B.
James Byrd, Marta Kozak 28 Apr 2011
Dual-stream UHPLC separations on a new, compact, sample delivery system featuring simplified software automation for increased throughput in drug discovery.
Tandem MS.
Multiple Reaction Monitoring (MRM) Selected Reaction Monitoring (SRM)
Alltesta HPLC Analyzer Analysis of Pesticides, Dyes, and Drugs
For Forensic Toxicology use Only
Mass Spectrometry Vs. Immunoassay
Automation of Sample Preparation for Trace Analysis Haibin Wan
C. Costa, R. Webb, V. Palitsin, M. Ismail, M. de Puit, S. Atkinson, M
Extraction Procedure (2)
High Resolution Quantitation of Microcystins with SCIEX X500R QTOF System KC Hyland.
Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent
VAPOUR PHASE CHROMATOGRAPHY
How to quantify substances in a mixture using gas chromatography
Gas chromatography Software
Presentation transcript:

Unstoppable productivity; Uncompromised MS/MS simplicity Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS/MS Unstoppable productivity; Uncompromised MS/MS simplicity

2 Triple Quadrupole GC-MS/MS is an essential part of a cost- effective, high productivity analytical method in today’s laboratory

3 Many laboratories are already investing in and exploring GC-MS/MS as a tool to obtain a competitive edge in their analyses

4 Routine laboratories face tough challenges High sample loads/short deadlines Keeping sample analysis costs down with more and more challenging LODs and matrices Integrating and maintaining new methods and technologies into production workflows to remain competitive

5 What‘s required.. Realization of the productivity advantages of high performance GC-MS/MS Minimizing the impact of adoption and implementation to current laboratory operations

6

7 “To make the productivity advantages of high performance GC-MS/MS easy to achieve and available routinely; especially for high-throughput laboratories.” Design philosophy

8

9 Routinely achieve regulatory detection limits with confidence Use highly powerful MS/MS to bring new capability Not just MS/MS performance High Sensitivity in MS mode for Full Scan/SIM work

10 Designed for more robustness; for more uptime and more results reported Powerful SRM enables optimized sample preparation for faster results Consolidated, faster methods with more compounds in one run

11 Fast and simple route to high performance MS/MS with integrated software tools like AutoSRM Automatically optimized instrument methods for maximum analysis sensitivty with t-SRM Synchronized instrument and data processing methods for maintaining efficient workflows

12

13 Routinely achieve regulatory detection limits with confidence Full Scan SIM SRM Dichlorvos in mixed herbal extract at 5 ppb Cut through chemical backgroundCut through chemical background High selectivity in matrix compared with single stage MS Selected Reaction Monitoring (SRM) S-shaped curved ion guide lens High precision at low concentrationsHigh precision at low concentrations Femtogram level detection Confirming ions

14 Highly powerful MS/MS to bring new capability Low-level multi-drug class screen in oral fluid.. Cocaine & BZE at 0.8 ng/mL THC and THCA at 0.2 ng/mL (all with quantitative and confirmatory ions) Use the high speed & sensitivity of the TSQ™ 8000 GC-MS/MS Use the high speed & sensitivity of the TSQ™ 8000 GC-MS/MS For more compounds More confirmatory ions Achieve low noise and clean peak detectionAchieve low noise and clean peak detection Less manual integration changes Fast data processing Add versatility Add versatility Easy addition of new compounds to methods

15 Not just MS/MS performance High full scan spectral qualityHigh full scan spectral quality Searchable with NIST etc. High sensitivity SIM & Full ScanHigh sensitivity SIM & Full Scan Virtually indistinguishable from a single quadrupole instrument Dual acquisition modesDual acquisition modes Quan & qual in the same run Lindane isomers 40 ppb in cucumber in simultaneous full scan/SIM Full Scan SIM

16

17 Designed for more robustness; for more uptime and more results reported EU limit for LOQ %RSD BeforeAfter %RSD pesticides (10 ppb) before and after 1,400 vegetable matrix injections Design based on strong reputationDesign based on strong reputation Thermo Scientific ISQ Single Quadrupole GC-MS Routine-grade robustnessRoutine-grade robustness Thermo Scientific ExtractaBrite ion source- no-vent maintenance Heated sample path zones for reduced ion burn Innovative GC modularity Innovative GC modularity Thermo Scientific TRACE 1300 Series GC Optimized maintenance

18 Powerful SRM enables optimized sample preparation for faster results Explore generic sample approaches Method consolidation Eg. QuEChERS Reduce number of stepsReduce number of steps Pre-concentration Clean-up Bring sample preparation onboard TSQ 8000Bring sample preparation onboard TSQ 8000 Thermo Scientific TriPlus RSH autosampler 1,3 –dichlorophenol, 1,4- dichlorophenol and 1,2- dichlorophenol (left to right) in ASE soil extract at 5 ppb.

19 Consolidated, faster methods with more compounds in one run Real example of method consolidation on the TSQ Five SIM methods combined to form a powerful MRM method for 350 pesticides (700 transitions) Method consolidationMethod consolidation Combine separate MS analyses Driven by selectivity of SRM Faster run timesFaster run times Compress chromatography Using MS/MS resolution Clean peak detectionClean peak detection Less manual integration changes Fast data processing

20

21 A fast, simple route to high performance MS/MS AutoSRM Unknown SRM Transitions The very beginning or a SIM Method TSQ 8000 Inst. Method Known SRM Transitions From an existing method or SRM Transition list Thermo Scientific TraceFinder SW Optimized SRM Transitions From Compound Data Store or existing TSQ 8000 method Method Sync SRM Optimization Starting Point Integrated SRM management tools SRM creation and method management independent of your starting point

22 Fast,simple route to high performance SRM with AutoSRM 1) Precursor ion selection 2) Product ion selection 3) Collision energy optimization AutoSRMAutoSRM manages the SRM method development workflow From discovery through to final optimization

23 Automatically optimized methods for high sensitivity with t-SRM Retention timed-based acquisitionRetention timed-based acquisition Simple method management No more window calculations Timed-SRM (t-SRM)Timed-SRM (t-SRM) RT information from user or compound data store (CDS) Optimizes duty cycle Ensures maximum method sensitivity, precision and accuracy. Peaks never on the edge of windows Timed-SIM (t-SIM) also possibleTimed-SIM (t-SIM) also possible

24 Synchronized methods for maintaining efficient workflows MethodSyncMethodSync synchronizes acquisition and processing methods Exchange SRM and RT information Instrument method, TraceFinder™ SW CDS

25 Brilliant design, brilliant results Dual Filaments for Prolonged Uptime Heated ion guide protects main quadrupole sets so they never have to be cleaned or replaced. Curved ion guide enables off-axis optics to effectively eliminates neutral noise Choose between nitrogen or argon for collision gas. No expensive helium is required Full source removal without venting, including ion guide surface. No wire connections are necessary, and never vent to clean your instrument. Super fast analyzers switch between Full Scan, SIM and MRM in milliseconds.

26 Unstoppable productivity starts with TRACE™ 1300 Series GC Instant Connect (iC) injector and detector modulesInstant Connect (iC) injector and detector modules User switching in minutes For maintenance or flexibility Low thermal mass design throughoutLow thermal mass design throughout Fast heating and cooling for higher sample throughput TriPlus™ RSH autosamplerTriPlus™ RSH autosampler Automation of sample preparation steps Dilutions Addition of standards

27 TraceFinder; maximum productivity workflow-oriented software Workflow-centricWorkflow-centric Batch acquisition Integration to TSQ 8000 method Data processing User Role CapabilitiesUser Role Capabilities Simplifies routine workflow Active ReportingActive Reporting Dynamic updates based on real-time changes Application VariantsApplication Variants Environment & Food Safety Clinical Research & Toxicology

28 High performance Unstoppable productivity MS/MS simplicity TSQ 8000: Core values for the routine choice in GC-MS/MS

29 Your next competitive advantage