1 Powerware 9170+ 3 - 18 kVA The modular, scalable, redundant UPS for midrange applications.

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
G.E. UPS Productline.
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
The Smartest Line- Interactive UPS with Pure Sine Wave Output in High Frequency Technology.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
LP33 Series UPS kVA 400Vac/CE
DPA TM UPScale Best-in-class modular UPS for maximum availability.
Mars RT Pro On-Line Series UPS
NT series introduction UPS training June 2006 Markus Schwab.
UPS H series introduction UPS training June 2006 Markus Schwab.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
MC-1610MR / MC-1610MR48 16-Slot Managed Media Converter Chassis Copyright © PLANET Technology Corporation. All rights reserved.
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
Newave SA, Switzerland – - 28/02/ Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT.
FG Wilson Access 4000 Control Panel
Janus Convertible Line – interactive Series UPS
MarsⅡ On-Line UPS Series
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
ENERGY of 21 st Century Independent Power Supplies.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Smart Grid: Opportunities in the Data Center January 22, 2010 Charles O’Donnell, Vice President, Engineering Liebert AC Power Emerson Network Power.
Modular Inverter.
Delivering total power infrastructures worldwide for IBM.
RACK Mountable & Modular Continuous Power Protection Availability
Model A 19-inch Rack Static Transfer Switch. Why choose a model A static transfer switch? Break before make transfers Break time < ¼ Cycle Will not transfer.
LP Series 400V CE GE Consumer & Industrial September 2004.
© 2014 Eaton. All Rights Reserved.. Eaton 93PM: Value, Benefits, and Features.
1 Powerware VA – 3kVA Nonstop perfect power for networks, web servers and telecommunications applications.
LEADING THE PACK.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
© 2007 Eaton Corporation. All rights reserved. Powerware ® BladeUPS Highest efficiency power protection for today’s IT environment.
FLATPACK Rev.5 September 2002 Updated versions may be available.
InfraStruXure Systems Alex Tavakalov
93E Eaton 93E kVA UPS Sales Presentation.
© 2011 Eaton Corporation. All rights reserved. Configuring BladeUPS™
© 2013 Eaton Corporation. All rights reserved. Eaton 93E kVA UPS Sales Presentation 93E.
Avaya VA Line-interactive UPS
Avaya Online UPS 6000 VA.
RACK Mountable & Modular Continuous Power Protection Availability
93E Eaton 93E kVA UPS Sales Presentation.
New 9E Range 6-20kVA Presentation Title.
Avaya Online UPS 6000 VA.
V7 UPS Sales Training.
RACK Mountable & Modular Continuous Power Protection Availability
230 Yuma Street Denver, CO (800)
Liebert APS.
230 Yuma Street Denver, CO (800)
PowerValue 11 RT Sales Presentation
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
Best-in-class modular UPS ensuring business continuity
Introducing the new 700–3000 VA UPS from Eaton
Eaton 93PM: Value, Benefits, and Features
Avaya Online UPS Options
Presentation transcript:

1 Powerware kVA The modular, scalable, redundant UPS for midrange applications

2 The Powerware It’s about availability Reliability Efficiency Performance

3 Powerware Applications The is designed for the 24/365 availability needs of 3-18 kVA e-business applications featuring: –Servers –Networking devices (hubs, routers and switches) –Telecommunications/PBX –Long Runtime Applications (with new Charger Module) –Process control –Branch offices

4 Powerware Enhancements –XCP Protocol Compatibility –Increase Watt Rating - Split Phase Modules –Advance Battery Management (ABM) –Improved Front Panel Operations –Firmware Field Upgrade Capability –Active MOV Monitoring

5 Powerware Powerware Overview Modular, global design Scalable N + X redundancy Traditional 9 Series Power Protection Advanced Battery Management (ABM) Optional Charger for Long Runtime Applications Compact footprint/lightweight power and battery modules Enhanced, easy to use interface panel Flexible communication capability

6 Four freestanding UPS enclosures 3-slot: 3 kVA 6-slot: 3-9 kVA 9-slot: 3-18 kVA 12 slot: 3-18 kVA Powerware System Configurations The Powerware 9170+’s modular design lets users configure any level of power redundancy or battery run-time with optional charger they need.

7 Three freestanding Battery Enclosures 6 Slot 9 Slot 12 slot 12 Slot w/charger Two rackmount kit options 3-slot: 3 kVA 6-slot: 3-9 kVA Powerware System Configurations

8 Model PowerInput/OutputInput/OutputDimensions NumberRatingVoltage 1 Connection(s) ( H x W x D) 2 Weight. PW slot 3kVA VACConfigurable 17.8 x 17 x 25.4 in. 66 lb. PW slot3 to 9kVA VAC Configurable31.5 x 17 x 25.4 in. 103 lb PW slot 3 to 18kVA VAC Configurable 47 x 24 x 28.4 in. 158 lb PW slot 3 to 18kVA VAC Configurable60.7 x 24 x 28.4 in 196 lb 6 slot battery cab 31.5 x 17 x 25.4 in 93 lb 9 slot battery cab47 x 24 x 28.4 in148 lb 12 slot battery cab60.7 x 24 x 28.4 in186 lb Battery Module4.2 x 7 x 14.8 in30 lb Split Phase Power Module & VAC4.2 x 14.1 x 15.3 in17 lb Universal Power Module VAC 4.2 x 14.1 x 15.3 in17 lb Optional Charger Module4.2 x 14.1 x 15.3 in17 lb 1. Nominal input voltage range is VAC with maximum input voltage range of 176 to 276VAC. Split Phase Power Module offers both high and low output voltages, while the Universal Power Module offers only high output voltages.

9 Powerware Powerware Benefits / Features Cost of Ownership Capacity Modular in 3kVA blocks N+X option Charger option

10 Powerware Powerware Standard Features Global Product WW Frequency (47- 63Hz) Selectable WW voltages High efficiency mode Enhanced, Fault Bypass mode Standard hot-swappable internal batteries Continuous on-line, no- break transfer Sinewave Output

11 Powerware Powerware Standard Features Generator compatible Advanced Battery Management (ABM) Wide input voltage volts <10% input I THD Supports: non-linear loads 3:1 crest factor.9 lead to.5 lagging Power factor corrected

12 Powerware Powerware Standard Features LCD display Complete connectivity offering Com slot(s) RS232 Contact closure Remote EPO capable etc…. Enhanced,Easy diagnostics Power management software - XCP Compatible

13 Powerware Maximum Availability True double conversion online design –Adheres to IEC guidelines for Class 1 double conversion online UPS –Total independence and complete isolation between input and output for voltage and frequency –Wide input voltage range (176 to 276 VAC) –Frequency correction –Harmonics isolation Double conversion online is universally recognized as the highest performance topology

14 Powerware Maximum Availability / Reliability Features –Patented Universal Slots Any module - any slot –Hot Swappable Modules All modules with no load interruption –Patented Bypass 6kVA rated

15 N+X “Power and LOGIC” Redundancy Patented technology enables true N+X power redundancy The Powerware features logic redundancy as well, eliminating any vulnerability to system availability. The logic is contained in each 3kVA Power Module (not in separate redundant logic cards like Symmetra, Nfinity, etc.), allowing true N+X Power and Logic Redundancy No system-level single-point-of-failure in Powerware systems Virtually eliminates downtime and enhances serviceability – no need to transfer load to bypass during service Powerware Maximum Reliability

16 Powerware Powerware Standard Internal Options Receptacle panels –All cabinets Input cord options –3 & 6 kVA only Locking casters option –3 & 6 Slot only

17 Powerware Powerware Optional Charger Module Optional 20AMP Charger –20 amps of charging capability which can be paralleled for long runtime opportunities –Same Form Factor as 3kVA Power Modules Fits any standard slot –Housed in standard UPS cabinet or special 12 slot battery cabinet (ASY-0653) – Top 3 slots –Example: 18kVA system for 1 hour of runtime –One charger will yield 5.4 hours of recharge time –Two chargers will yield 3.1 hours of recharge time.

18 Powerware Powerware Internal Options Galvanic isolation (factory installation required) –3 Slot Housed in bottom of cabinet Removes bottom slot –6 Slot Mounted vertical rear Reduces receptacles to maximum 4 bays –9 Slot - not available –12 Slot Mounted vertical rear Reduces receptacles to maximum 8 bays

19 Powerware Powerware External Option Rackmount kits Extended runtime –6, 9, & 12 slot cabinets Wall mounted MBC –Make Before Break (MBB) –Break Before Make (BBM) Floor anchoring kits

20 Powerware Maximum Performance Enhanced, easy-to-use front control panel –Large 4 X 20 character back-lit LCD panel –Programmable for Power Saver Mode, alarm notification and communications –Illuminated indicators for UPS status –Multilingual LCD (English, French, German and Spanish)

21 Powerware Maximum Performance Flexible communication capabilities SNMP communication RS-232 DB-9 Web browser or modem access Software included On Line, On Generator, On Bypass, EPO notification Two communications slots

22 Battery Runtime Chart 1 String 2 String3 String4 String5 String6 String 3kVA 8/2424/5943/9558/14080/17595/125 6kVA 8/2416/4024/5932/8340/103 9kVA 8/2413/3518/4624/59 12kVA 8/2413/3316/40 15kVA 8/2411.5/31 18kVA 8/24 7 String 8 String9 String10 String11 String12 String 3kVA 119/240135/290155/335165/365200/395215/450 6kVA 49/11458/14069/15683/17590/190103/205 9kva 29/6335/8640/10346/11554/12558/140 12kva 19.5/43.524/5929/7033/8036/9041/100 15kva 14.5/31.518/4620.5/5124/5828/6631/73 18kVA 11/31.513/3615.5/4118/4520.5/5124/58 (Full load/Half load) Runtimes above solid line require new optional charger or additional power modules.

23 13 string 14 String15 String16 String17 String18 String 3kVA 225/500245/540270/600290/620315/650335/690 6kVA 113/335123/255135/273143/290148/315156/333 9kVA 63/15073/16580/17886/19093/200100/210 12kVA 47/11052/12156/13058/14065/14770/156 15kVA 34/8338/9441.5/ / /11751/127 18kVA 27/6531.5/7234.5/7736/8338/9441/ String 20 String21 String22 String23 String24 String 3kVA 350/720365/780375/850395/890425/920450/950 6kVA 165/350175/365183/385190/395198/420205/440 9kva 107/225115/240121/255125/270135/280143/290 12kva 75/16580/17585/18590/19595/205100/215 15kva 56/13058/14061/14966/15871/16573/170 18kVA 44/10545/11548/12254/13157/13758/140 Runtimes above solid line require optional charger or additional power modules. Battery Runtime Chart (Full load/Half load)

24 Power ware Power ware Pre-configured System Numbers Pre-configured UPS System Numbers: –Displayed on Powerware web site on page –Complete UPS Systems, including enclosure, Power and Battery Modules. –Available to ship immediately –Customer can order a complete UPS System with one part number or configure their own unique UPS system – the best of both worlds.

25 Powerware Powerware Pre-configured System Numbers

26 Powerware Thank You