Presentation is loading. Please wait.

Presentation is loading. Please wait.

A Wholly Owned Subsidiary of 456 Creamery Way Exton PA USA www

Similar presentations


Presentation on theme: "A Wholly Owned Subsidiary of 456 Creamery Way Exton PA USA www"— Presentation transcript:

1 A Wholly Owned Subsidiary of 456 Creamery Way Exton PA 19341 USA www
A Wholly Owned Subsidiary of 456 Creamery Way Exton PA USA

2 Closed-Circuit, Self-Contained, Breathing Apparatus CCSCBA
Built to Bring You Home™ Closed-Circuit, Self-Contained, Breathing Apparatus CCSCBA

3 ISO 9001:2008 Certified Founded in 1969 by aerospace life support engineers working on NASA manned lunar missions. Pioneered positive-pressure CCSCBA for use in toxic or oxygen-deficient atmospheres, 1985. Pioneered solid core carbon dioxide scrubbers in CCSCBA applications, 2008. NIOSH/MSHA (USA), EN136/145 (Worldwide), DGMS (India), GOST (Russia) and MA (China) certified product and quality systems. Legacy Products: BioPak 30, BioPak 45, BioPak 60, BioPak 60TE, BioPak 240P, BioPak 240LW, BioPak 240S

4 APPLICATIONS: Mine Rescue Tunnel Rescue Fire Service
First Responder Search & Rescue Law Enforcement HAZMAT Response Confined Space Entry Petro-Chemical Military Government Toxic and Oxygen Deficient Atmospheres

5 FEATURES: Positive-Pressure, Closed-Circuit Operation Enhanced Safety
Simplicity of Use Enhanced Comfort Rapid Deployment Reliability Simplified Maintenance Hydration System Customization Product and Customer Support

6 POSITIVE-PRESSURE OPERATION:
Maintains breathing pressure in the facemask above external ambient pressure during both inhalation and exhalation breathing cycles. Resists the ingress of external atmospheric toxins into the breathing gas of the BioPak.

7 CLOSED-CIRCUIT OPERATION:
Breathing gas is recycled to conserve oxygen and prolong duration. Closed-circuit operation limits potential leak points and prevents the ingress of external atmospheric toxins. Large tidal volume and low pressure drop throughout system results in ease of breathing. Extended duration over open-circuit design of identical mass: Open-Circuit Duration: 45 – 60 minutes Closed-Circuit Duration: 240 minutes Lower exhalation resistance as compared to open-circuit.

8 ENHANCED SAFETY-SOLID CORE CARBON DIOXIDE SCRUBBER:
Eliminates User Filling: Protects against lethal filling errors. Eliminates user handling of caustic chemicals. Eliminates user exposure to caustic dust. Provides consistent fill resulting in consistent breathing resistance Non-Dusting Non-Channeling Non-Settling Eliminates all generated free water 3-year shelf life in factory packaging 1-year shelf life “pre-packed” into BioPak

9 ENHANCED SAFETY-SYSTEM:
Static-Resistant Housing Flame-Resistant Materials (click on square to see EN-137 flame resistance testing) Protected Diaphragm Anti-Fog Laminate Film and Wiper Simplified System Interface Remote Gauge Leak Isolation

10 SIMPLICITY OF USE: At-A-Glance System Interface
Single Point Activation even while wearing gloves Permanent Anti-Fog “Plug & Play” CO2 scrubbers Automatic Adjustment to Breathing Rates Reusable Coolant Modules

11 ENHANCED COMFORT: Lowest Breathing Rate Available
Ergonomic Housing Design Padded & Adjustable Harness Optional Hydration System Multiple Mask Sizes Ice Canisters can be replaced in hazardous zone

12 RAPID DEPLOYMENT: “Plug & Play” scrubber with “Pre- Pack” option
Quick Make & Break Harness Phase Change Heat Exchanger Slip-in Ice Canisters Single Point Activation At-A-Glance status indication

13 RELIABILITY: Less Complicated Alarming System: Provides At-A-Glance recognition of system status eliminating user confusion due to oversaturation of data and avoiding costly alarming system breakdowns.. Lower Part Count: Fewer parts yields higher reliability, fewer parts to test, disinfect and qualify. Protected Breathing Chamber: Rubber diaphragm of system is protected on all sides by hard plastic thus eliminating dangers of puncture or tearing should the upper housing become dislodged. Historically Proven Pressure Regulator: The BioPak 240R pressure regulator has over 40-years experience in both CCSCBA and SCUBA applications without a demonstrated need for factory rebuilds or calibration over its life time. Proven Field Support: Biomarine and its Distributor Network take pride in the post sale service and support provided to end users through direct training, emergency support and product support.

14 Competitor Tear Down Parts
REDUCED MAINTENANCE-TURN AROUND: BioPak Tear Down Parts (as per manual) Competitor Tear Down Parts (as per manual) Reduced part count for tear down, disinfection, reassembly and testing. Quick-release breathing loop for speed of tear down and reassembly: Two (2) pneumatic connections One (1) electrical connection Four (4) ¼-turn hold downs

15 REDUCED MAINTENANCE-LIFE:
Reusable Coolant Modules No filling No shaping No replacement Single step freeze procedure, no multiple freeze cycles required Tool kit provides all tools and equipment for all BioPak service. Optional tools available to enhance testing or speed maintenance times: Digital High Pressure Leak Detection Mask Test Kit Quantitative Fit Kits Booster pumps and adapters Drying manifolds No mandatory component replacement or re-calibration Pressure regulator will last life of the BioPak. Oxygen cylinder requires hydro-testing every 5-years, 15-year total life

16 HYDRATION SYSTEM: Provides up to 1.5-liters of liquid storage.
Allows user hydration through face mask port without introduction of external atmospheres that may contain toxins. Bladder can stow on harness waist belt, strap to user leg or secured in other manner. Bladder can be removed and discarded in toxic zone without introducing BioPak leaks or ingress of external atmosphere or toxins. Large bore feed tube provides ease of drawing liquid to user. Hydration system will interface all BioPak mask types.

17 CUSTOMIZATION: Biomarine is willing to customize in order to meet the needs of the end user. Customization is limited by the quantities involved and the impact upon third party agency approvals. Customization can include, but is not limited to, the following: BioPak 240R Modifications Manual Content or Language Testing procedures and/or Tools Emergency Procedures Training Contents and Methods

18 SUPPORT: User Training: Instructs users in the donning, normal use, emergency use and doffing of the BioPak. Benchman Training: Instructs in BioPak theory, maintenance, service and troubleshooting. Instructor Training: Instructs in BioPak User and Benchman training theory. Training Sites: Training can be conducted at the Biomarine factory or at the end user cite. Emergency Support: Provides end user manpower and equipment supplies and support during emergency events. Distributor Network: Provides direct face to face post sale product and service support to end users. Once a user becomes part of the Biomarine family they can rest assured that Biomarine and the Distributor Network will attend to all of their product, training and support needs.

19 CO2 O2 FUTURE BIOPAK 240R DEVELOPMENTS:
Biomarine constantly strives to improve the BioPak 240R product based upon inputs received from the field. End users are encouraged to suggest improvements based their experience in actual field utilization. Technology searches are constantly conducted by the Biomarine Research and Design teams . Once a new technology is found to be plausible in the BioPak 240R design, the Biomarine Engineering Group works to incorporate the new technology in a manner that will be favorable to field retro-fit. Lighter and Stronger Materials Carbon Dioxide Capture Technologies Oxygen Storage Technologies Moisture/Fogging Management Technologies Ergonomic Technologies CO2 End user input and satisfaction is the driving force behind all Biomarine designs and product implementations. O2

20 SPECIFICATIONS: Country of Manufacture: USA
Certification: Positive-Pressure, Closed-Circuit, Pressure-Demand, 4-Hour Duration, Entry and Escape Certification Agencies: NIOSH/MSHA, EN136/145, DGMS, MA, GOST Mass (fully charged, including mask): 15 kg (33 lbs) Size: 584 x 439 x 178 mm (23.0 x 17.3 x 7.0 inches) Tidal Volume: Greater than 6-liters Breathing Resistance: Lowest available on the market Oxygen Delivery: Constant Add Rate: 1.8 lpm AVERAGE Demand Add Rate: 80 lpm MINIMUM Emergency Add Rate: 80 lpm MINIMUM Oxygen Cylinder: bar (3000 psi), Aluminum Liner, Carbon Fiber Over Wrap

21 SPECIFICATIONS: Carbon Dioxide Scrubber:
Dual Canister, Solid Core, Non-Dusting, Non-Settling, Non-Channeling, Factory Pre-Packed, Moisture Retention 3-Year Shelf Life Consumables: 9 Vdc Battery: 200-hours or 6-months CO2 Scrubber: Replace after each use Oxygen: Re-charge cylinder after each use Coolant: Re-freeze after each use Mandatory Component Rebuilds/Replacement: Other than the oxygen cylinder, there are no mandatory component replacements, rebuilds or recalibrations required for the life of the BioPak. Components such as seals and gaskets are replaced only when visual inspections or leak tests are failed prior to use. Oxygen Cylinder Life: 15-years Oxygen Cylinder Hydro-Test: Every 5-years

22

23 Contact Biomarine through our website at:
The website will provide direct factory contact information, distributor listings and access to various training aids, manuals and technical information.


Download ppt "A Wholly Owned Subsidiary of 456 Creamery Way Exton PA USA www"

Similar presentations


Ads by Google