ERX-condensing units Strategic Marketing. 2 17-Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits.

Similar presentations


Presentation on theme: "ERX-condensing units Strategic Marketing. 2 17-Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits."— Presentation transcript:

1 ERX-condensing units Strategic Marketing

2 2 17-Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits

3 3 17-Dec-15 Pair application: ERX + EV + control box + AHU ERX R410A inverter Sky Air Outdoor unit Air Handling Unit EV kit F1F2 communication Refrigerant piping Control box Field Supply 1. Concept ERX are R410A inverter units for use with AHU in pair applications ERX is always used in combination with expansion valve kit (EV kit) and a control box ERX can not be used with standard Sky Air indoors ERX are R410A inverter units for use with AHU in pair applications ERX is always used in combination with expansion valve kit (EV kit) and a control box ERX can not be used with standard Sky Air indoors DAikin Supply

4 4 17-Dec-15 Multi application : standard VRV outdoors + EV + control box : Standard VRV Outdoor unit Air Handling Unit EV kit Refrigerant piping Control box VRV indoor VRV indoor F1F2 communication Field Supply DAikin Supply 1. Concept

5 5 17-Dec-15 A. ERX Condensing Units (pair applications) ERX 100,125,140 (1 phase) ERX 125, 200 (3 phase) ERX 250 (3 phase) 2. Product range

6 6 17-Dec-15 B. EV Kit and Control Box (Pair and Multi) EV Kit Control box 2. Product range

7 7 17-Dec-15 ERX100 : EV 63 – 125 ERX125 : EV 63 – 140 ERX140 : EV 80 – 140 ERX200 : EV 100- 250 ERX250 : EV125 - 250 To allow max connection to AHU a range of expansion valve kits are available for each outdoor 3. Combination table

8 8 17-Dec-15 Piping limitations: Pair Application (Sky Air) Daikin condensing unit EKEXFCB EKEXDCB AHU EXV-kit DDC AB CD E F Total system : ≤ 30 m (Outdoor unit can be above or below the AHU) outdoor EXV-kit AHU ≤ 5 m Allowable height Piping Communication ERX 1 phase ERX 3 phase 100 125 140 125 200 250 length : 5 < A ≤ 50m length : ≤ 5 m ≤ 100 m ≤ 20 m Depend On DDC ABCDEF 4. Piping length

9 9 17-Dec-15 Piping limitations: Multi Application (VRV) Daikin condensing unit EKEXMCBAHU EXV-kit DDC AB CD E F KIT n Indoor 1 Total system : ≤ 40 m (outdoor unit can be above or below the AHU) outdo or EXV-kit 1 AHU 1 ≤ 5 m Allowable height ≤ 5 m ≤ 15 m EXV-kit n AHU n Piping Communication VRV-III A+BBCDEF Consider Same as indoor length : ≤ 5 m ≤ 50 m Depend On DDC VRV Wiring policy 4. Piping length C/O 5~18 HP

10 10 17-Dec-15 AHU Te Ts Td Tr ROOM DDC X : Control of air Temperature (Td, Ts, Tr) with external controller (DDC)  PAIR Y : Control of evaporating Temperature (Te) with Daikin controller  PAIR Z : Control of air temperature (Ts, Tr) with Daikin controller  PAIR & MULTI 3 control systems can be selected : 5. Control possibilities

11 11 17-Dec-15 Te Ts Td Tr ROOM DDC EV kit Control box Example: Control X (pair) 5. Control possibilities

12 12 17-Dec-15 Example: Control Y (pair) (Te : 3~8°C) Te Ts Td Tr ROOM EV kit Control box 5. Control possibilities

13 13 17-Dec-15 Te Ts Td Tr ROOM Daikin EV kit Control box Example: Control Z (pair and multi) Controller 5. Control possibilities

14 14 17-Dec-15 System overview 5. Control possibilities XYZ Daikin Field supply System System A: Pair system : ERX OOO System B: Multi system : VRV --O Control parameterDischarge air control (Td)O-- suction air control (Ts)O-O Room air control (Tr)O-O Evaporating temp control (Te)-O- Components for control DDC (digital controller) O--field Air thermistorO--field Air thermistor -- ODaikin BRC1D - (2)- (2) (5) O (3)Daikin KRP4A (remote On/Off)--O (4)Daikin (2) not needed for control purpose (only for service: fault code detection) (3) required: to be ordered separately as option (4) possible, but not required: to be ordered separately as option. Supply of partsType of control EKEXFCBAV3 (customer can select X or Y) EKEXDCBAV3 (pair) EKEXMCBV3 (multi) (5) Te setting changed by BRC1D (=service tool)

15 15 17-Dec-15 5. Control possibilities Control systems typedescriptionPROCONTRA Control type XBy DDC controller : 0-10 V control ΔT = T set - T measured T = Td, Ts or Tr - possibility for Td control - flexibility in applications - higher cost (DDC is needed) Control type Y Fixed Te Te = user setting : 3 ~8 °C - Low cost - no BRC needed no air temp control Control type Zusing BR1CD + KRP4 (remote on/off) Low cost - BRC/KRP4 needed - no possibility for Td control -ΔT+ΔTTset 0V 5V 10V output ΔTΔT T DDC set T measured 0~10 V

16 16 17-Dec-15 Customer benefits 1. Inverter outdoors (ERX or VRV) 2. Pair (ERX) and multi applications (VRV) 3. Extended control systems possible : control on evaporating temperature control on air temperature (suction / discharge / room temperature) Compared to Chillers : 1.Same small temperature gradient and control possibilities 2.No hydraulic components 3.Better price setting 6. Benefits