Presentation is loading. Please wait.

Presentation is loading. Please wait.

N5000 Q-in-Q Test Report. - 2 - 테스트 구성도 Tagged packet vid : 560 Tagged packet vid : 560 Untagged packet Q-in-Q vid : 10, 130.

Similar presentations


Presentation on theme: "N5000 Q-in-Q Test Report. - 2 - 테스트 구성도 Tagged packet vid : 560 Tagged packet vid : 560 Untagged packet Q-in-Q vid : 10, 130."— Presentation transcript:

1 N5000 Q-in-Q Test Report

2 - 2 - 테스트 구성도 Tagged packet vid : 560 Tagged packet vid : 560 Untagged packet Q-in-Q vid : 10, 130

3 - 3 - N5000 Configuration Module settings Opermode : qinq

4 - 4 - N5000 Configuration Port settings 0/u0,u1 type : trunk Pvid : any pvids Vlan settings

5 - 5 - Test Result Data transmission No packet loss

6 - 6 - Test Result Data transmission VLAN tagged packet capture Double-tagged frame sent from N5000 on the transmission side, on the receiving side on the N5000 untagging is done for the double-tagged frame and in the end the N2X receives only C- VLAN tagged frame.

7 - 7 - Test Result Data transmission untagged packet capture Untagged frame is set to VLAN tagging on Q-inQ pass and then that is untagged on receiving side N5000.

8 - 8 - vid :560 COT-1COT-2 Untagged packet Q-in-Q vid : 130

9 - 9 - COT-1 Configuration Module settings Opermode : qinq

10 - 10 - COT-1 Configuration Port settings 0/u0,u1 type : trunk Pvid : any pvids Vlan settings

11 - 11 - COT-2 Configuration

12 - 12 - Test Result Data transmission Q-in-Q packet capture Double-tagged packet for VLAN tagged input packet Tagged packet for untagged input packet


Download ppt "N5000 Q-in-Q Test Report. - 2 - 테스트 구성도 Tagged packet vid : 560 Tagged packet vid : 560 Untagged packet Q-in-Q vid : 10, 130."