2 December, 2015 New Conventional Fire Control Panel.

Similar presentations


Presentation on theme: "2 December, 2015 New Conventional Fire Control Panel."— Presentation transcript:

1 2 December, 2015 New Conventional Fire Control Panel

2 2 Introduction History Objectives Features Benefits

3 3 History  System 8 (1980 - 1990) Fixed format 2 and 4 zone Modular 8,16,24 to 64 Zone Extinguishing Release Module (ERM) version FOC approved - BS3116 part 4  Firebeta MKI (1988 - 1997) Fixed Format 2 and 4 Zone Modular 8,12,16,20, to 120 Zones Designed to meet BS3116, BS5839 and UL864 ERM version

4 4 History Sirius (1992 - present) Fixed format 2,4,8,16 and 32 Zone ERM version LPCB, HKFS approved to BS5839 part 4 Firebeta MKII (1999 - present) Fixed format 2 and 4 Zone budget 2,4,8 and 12 zone Standard version Designed to comply with EN54 part 2 and 4 ECP variant

5 5 Objectives  New fully featured Conventional panel with approvals  Prepare for introduction of Construction Products Directive  Replace ageing Sirius products  Substitute for non approved Firebeta 2  Extend the range of ancillary product - PSU, Battery boxes etc  Introduce an RTC/Alarm counter variant for Export territories

6 6 Features  Range 2, 4 and 8 Zone Format  Fully Compliant with EN54 2 & 4 and BS 5839 part 1 (detector removal)  Integral zone device removal with short and open circuit monitoring - no AEOL.  Wide range of detectors supported, Apollo, Hochiki, Nittan, Gent and System Sensor

7 7 Features  2 x Alarm Circuits rated at 1 amp @ 28Vdc  1 x Monitored Fire Output – Fire routing equipment  1 x VFCO Contact – Auxiliary Common fire output  1 x VFCO contact - Auxiliary Common fault output  Repeater Output - RS485 2 Core connection  Monitored Class Change Input  Auxiliary Supply Output - 28 volt rated 500mA fused

8 8 Features  2 x 16 LCD Display with intuitive on screen user prompts  2.5 amp Switch Mode PSU with intelligent battery monitoring  Earth fault monitoring disable facility  Buzzer disable facility  Pass code Access – EN 54 - 2  Access\Inhibit Key switch option

9 9 Option Card Features  Input \ Output Interface card 8 x Inputs – monitored for open & short circuit Class Change External Fault Input Silence Alarms Input Reset Input 4 x spare 8 x Outputs – VFCO relay contact Zone 1 to 4 Repeat Outputs – ERM trigger Manual Evacuate output Silence Alarms output (5 second pulse) Panel Reset output (5 second pulse) Alarm Repeat output (any fire condition)

10 10 Option Card Features  8 Way Sounder Output Card Outputs rated at 1 amp @ 28 V d.c Individual switch 0 volt inputs activate circuits Common operation Zone by zone Pulse and timed options Remote PSU \ sounder booster unit option  8 Way VFCO Relay Output Card Relay contacts rated at 1 amp @ 28 V d.c Operation - Zone of origin constant remaining zones silent

11 11 Option Card Features  8 Zone Repeater Panel Powered by main panel auxiliary output Option for external PSU Zone Repeat outputs – (open collector 0 volt outputs) Support for 7 Active and 7 Passive Maximum 500 metres 2 core + screen cable connection (Ext PSU) 4 core + screen cable connection (Aux O/P)

12 12 Features  One Man Walk Test  Zone Disable/Isolation  Alarm Management (T1 & T2)  Non-latching zone facility  Zone Co-incidence  Output Delays (T3 & T4)  Alarm Counter – 999 alarm conditions  RTC – Clock frozen at time of 1 st Zone Alarm Condition

13 13 Enclosure Features Polycarbonate Moulded Outer Door with metal back box  Space for 2 x 7Ah batteries  LCD Display 2 x 16 character  Zone legend text inserts  Logo insert  Dimensions - 350mm W x 280mm H x 100mm D

14 14 Enclosure

15 15 Enclosure

16 16 Enclosure

17 17 Enclosure

18 18 Enclosure

19 19 Product Range  2, 4 and 8 Zone variants  Input \ Output Interface card  8 Zone Repeater Panel  8 way Sounder card  8 way Auxiliary Relay card  Access inhibit key switch  Sounder Extension \ Booster Unit + PSU  2.5 amp PSU space for 2 x 7 AHr batteries  2.5 amp PSU space for 2 x 12 AHr batteries  Battery \ Interface Box housings

20 20 Typical Applications Developed for the professional installer Flexible in design, installation and operation Small cost conscious installations Applications include: Industrial units Schools Shop units Residential Premises Small Hotels

21 21 Benefits  Price/Performance  Accredited product - CPD  Simple to Install, Service & Maintain

22 22 The New Conventional Fire Control Panel


Download ppt "2 December, 2015 New Conventional Fire Control Panel."