Presentation is loading. Please wait.

Presentation is loading. Please wait.

2012/02/08 1 Primax Confidential 1 Primax Barcode Label Requirement For All Primax Plants 2012.02.08 update (English version)

Similar presentations


Presentation on theme: "2012/02/08 1 Primax Confidential 1 Primax Barcode Label Requirement For All Primax Plants 2012.02.08 update (English version)"— Presentation transcript:

1 2012/02/08 1 Primax Confidential 1 Primax Barcode Label Requirement For All Primax Plants 2012.02.08 update (English version)

2 2012/02/08 22 Purpose and Scope Purpose –Due to Primax will implement WMS system (warehouse management system) and shop floor control system to manage incoming materials, suppliers shall apply barcode label on shipping goods. Scope –Every supplier who delivers goods to Primax warehouse shall follow this requirement. Implementation Date : –Phase I—Jan 1 st, 2012 (Primax MI/Q/IDD factory) –Phase II—Apr 1st, 2012 (Primax all factories) Label Type –Package barcode label –*SMD Reel barcode label (Most of SMD Reel could use Small package label on box or carton, but for some SMD component may need stick on each reel directly.) –List barcode label

3 2012/02/08 3 Primax Confidential 3 WMS Barcode Label Content and Introduction

4 2012/02/08 44 Package Definition Small Package  It is the basic unit for barcode label sticking. Small package is defined as container which contains material, such as carton, container, plastic bag, bottle, can, SMD reel… etc. The rule is : one small package must contain the same part number and lot no. Medium Package  It contains 2 or more small packages. Large Package  It contains 2 or more medium packages or mix of medium and small packages.

5 2012/02/08 Package Barcode Label Type Package Label (hereinafter referred to as P-label) as right figure shown. Label Size: ≥60*80mm (we only defined minimum size. Supplier can choose to use larger size if required.) Barcode coding : Code 128 min. 60mm min 80mm Q’TY. LOT NO. UOM : PCS BOX ID. SUPPLIER: XXX 公司 PRIMAX PART NO: 102100442030 PART NAME: Plastic Washer ADD'L INFO. G+HF+R2 SHIP TO. PRIMAX MI 廠

6 2012/02/08 6 SMD Reel Barcode Label Type This special label is used to Small amount of diversity SMD reel (hereinafter referred to as SMD-label) Size : ≥ 70*40mm (minimum size) Barcode Coding : Code 128 [Remark] 1.If shipment carton contains the same lot no. and component, please use P- Label on carton instead of SMD-Label on each reel. 2.This label could replace SFC Label. Q’TY. LOT NO. UOM : PCS BOX ID. SUPPLIER: XXX Corp. PRIMAX PART NO: 102100442030 PART NAME: 100K OHM RESISTOR Min. 70mm Min. 40mm G+HF+R2 SHIP TO. PRIMAX MI Plant

7 2012/02/08 7 Package Label Content Q’TY. LOT NO. UOM : PCS BOX ID. SUPPLIER: XXX Corp. PRIMAX PART NO: 102100442030 PART NAME: PLASTIC WASHER ADD'L INFO. INSP. RESULT: PASS INSP. BY: PETER CHEN G+HF+R2 Supplier Name Primax Part Number and Part Name Box ID, See page 10 Supplier Lot No, See page 15 Quantity in this container Additional Info. See page 19 GP marking, see page 16 SHIP TO. PRIMAX MI Plant Ship to which Primax Plant

8 2012/02/08 8 Package Label Content Integrate current Primax shipment label and green label requirement. HF *When supplier implement new barcode label on shipment carton, there is no need to stick shipment label and green label as shown on right figure.

9 2012/02/08 9 List Barcode Label Type If 2 or more different part number or lots packed into carton, the carton need stick List label (hereinafter referred to as L-label). Size : ≥ 90*70 mm (we only defined minimum size. Supplier can choose to use larger size if required.) Barcode Coding : Code 128 min70mm min 90mm *PRIMAX PART NO. and GP marking is used only for carton which have the same Part No but different lot. If carton contain multiple Part No., Please don’t fill up Primax Part No. and GP marking.

10 2012/02/08 10 BOX ID Coding Rule BOX ID (Total 16 digits) PO No.(10) Item(3) Serial No.(3) –PO No. and PO Item refer to next page. –If PO Item shows less than 3 digits, please make it up to 3 digits. Ex. Item 5  005, 20  020 –Serial No. 3 digits (Choose one of the following 2 types) Type 1 : decimal, up to 999 boxes (starting from 001) Type 2 : base 36 , 0~9 A~Z (starting from 001 to YZZ, do NOT use Serial No. bigger than YZZ.) –BOXID must be unique for every carton. Repeated BOXID is not acceptable. 1234 5 678910 111213141516

11 2012/02/08 11 BOX ID Coding Rule You can get PO and Item number from Primax e-Supply system “Purchase Information” or “Delivery Control Report”

12 2012/02/08 12 BOX ID Coding Rule Supplier may ship different PO items in one shipment. As long as part number and lot number are the same, you may put them into one carton. In such case, you could choose one PO number and Item No. from those multiple PO lines as BOXID and just use one P-label instead of many P-labels. (Suggest to choose PO number which is smaller), for example: –Parts A got 3 POs from Primax, you plan to ship it out today, and all the goods come from the same production lot. –PO/item  290020451/20 、 290020350/10 、 290020851/50 –If the size is small, you can pack it into the same box and stick one P-label instead of 3 P-labels. –And the BOXID goes to “ 290020350010001 ”.

13 2012/02/08 13 BOX ID Coding Rule BOX ID example-1: –PO: 2900012345 ; Item No: 1 –PO q ’ ty: 1000 pcs; Each box contains 100pcs –SN rule : base 36 –Lot No. 110716 have 850 pcs ; and Lot No. 110723 have 150 pcs –The BOXID goes to : Lot 110716—2900012345001001~2900012345001009 (The 9th box contain 50 pcs, and the others contain 100 pcs) Lot 110723—290001234500100A~290001234500100B(The 1st box contain 100 pcs and the 2 nd box contain 50pcs) (There are 11 boxes for shipping.)

14 2012/02/08 14 BOX ID Coding Rule BOX ID example-2: –One supplier receive 2 PO which are 2900012346 and 2900012347. The detail as below, PO No. Item No. Part No. Q’ty 2900012346 1 610000000001 1000 2900012346 2 610000000001 500 2900012347 1 610000000001 500 –Each box contains 100pcs, take decimal as SN rule. –2 PO No. and 3 items will be shipped at the same day. –Due to these 2 PO and 3 item are the same Part No. It can be use the same numbering but different SN. –Total 2000 pcs, pack into 20 boxes, The BOX ID goes to 2900012346001001~020

15 2012/02/08 15 LOT Number Rule Basically, lot number follows supplier’s internal lot numbering rule, but –Lot numbering must meet ISO9000 and industrial traceability requirement. –Example of lot number naming rule: Datecode, YYMMDD, YYWW, Plant code +Product code +YYMMDD…etc. –Lot number must meet FIFO requirement. –Lot number must be less than or equal to 16 digits.

16 2012/02/08 16 Green Product Marking GP marking use bold and rectangular frame and bold text. (see example as below) Please get GP grade content from e-Supply system.(See page 17~18) Example: G+HF+R2 S(G+HF+R2)

17 2012/02/08 17 Green Product Marking Normal Component CodeSpecial approved Component Code RoHSG S(G) RoHS+HFG+HFRoHS+HFS(G+HF) RoHS+RoHS2G+R2RoHS+RoHS2S(G+R2) RoHS+HF+RoHS2G+HF+R2RoHS+HF+RoHS2S(G+HF+R2) Green Product Marking RoHS=G (Pb/ Cd/ Hg/ Cr6+/ PBB/ PBDE) Halogen Free= HF (Br/ Cl) RoHS2= R2 (BBP/ DBP/ DEHP/ HBCDD)

18 2012/02/08 18 Green Product Marking Please get GP grade information from Primax e-Supply System

19 2012/02/08 19 ADD’L INFO. Additional information is for suppliers to maintain extra information on bar code label, the information may be requested by Primax plant’s special requirement. (As currently suppliers do on shipment label) Below requirements may need to be maintained in ADD’L INFO segment (depends on individual Primax plant’s request) : –Supplier Work Order No. –Primax P/O No. –Shift- Machine –Cavity- Inspector –Inspection Result- Box No.… If supplier wants to keep some information for your internal process, you can put the information in the bottom of the bar code label. (the more information, the larger label size is needed to make information clear.)

20 2012/02/08 20 Label Printing Note Text –Text font is not limited. Please use capital text of English. –If BOXID adopted by base 36, text font under the barcode must be easily identified “01OI”, Please use uppercase font, for example: Windows Consolas font  01OI Printing Method: –Please use thermal transfer instead of direct thermal. Direct thermal print will get fuzzy as time goes by.

21 2012/02/08 21 Example of Label Sticking Small package (the same part number and lot no.) Small box 21

22 2012/02/08 22 Example of Label Sticking Small package in Medium package –Each small package stick S-label, medium package stick L-label. Small box Medium box

23 2012/02/08 23 Example of Label Sticking Small in Medium in Large Package –Small boxes stick S-labels. –Medium boxes stick L-labels. –Large box stick L-label. Large Box Medium box Small box

24 2012/02/08 24 Position of Label Sticking For Box –Position of label sticking is as below figure. Priority as Middle>Right>Left, Once the position is decided, it must be consistent. Position priority of label

25 2012/02/08 25 Position of Label Sticking For Pallet –Stick label at obvious side (Label face outside) Stick label at obvious side WL

26 2012/02/08 26 Primax Stick Label for Supplier If supplier does not stick label on shipping box, Primax will help to make and stick the label. However, the expense will be charged to supplier. (deduct payment) Expense per label : CNY$ 10 / label –For instance, one supplier who shipped without sticking label, total 30 boxes in a shipment, Primax will make and stick 30 labels. The expense goes to 30*10=CNY$300.

27 2012/02/08 Unlabeled Queries Suppliers could query the number of boxes without barcode label from Primax e-Supply system.

28 2012/02/08 28 Notice Please implement barcode label to your shipments which will be delivered to Primax plants. For oversea suppliers, please mail barcode label sample and lot number naming rule to Primax SQE or Sourcing for confirmation by 2012/3/15. (we need the physical bar code label to test if the information can be read by scanner and if all information format follows our request) From 2012/4/1, if there is any shipment without barcode label, Primax will make and stick the barcode label. The expense will be charged to supplier monthly.

29 2012/02/08 29 Backup: Primax SFC Label

30 2012/02/08 Purpose and Scope Purpose: –Let Primax is able to trace the manufacture information of key parts through Primax SFC system (Shop Floor Control System) Scope: The parts which is defined as Key Parts by Primax. SFC Label Type: –SFC Barcode Label (for Mechanical, non-SMD component and others.) –SFC SMD Barcode Label (for SMD Component only)

31 2012/02/08 31 SFC Barcode Label Content Coding: Code 128 Label Size: Min 45*15mm SFC ID must be consistence to WMS P-Label Stick SFC label on smallest package (such as plastic bag, tray, reel…) SFC ID Primax Part No.(12~18digits) Supplier Short Name (ex. BC Electronic Co., LTD.  ”BC” or “BC company” are both acceptable) Min 45mm Min 15 mm

32 2012/02/08 32 Q’TY. LOT NO. UOM : PCS BOX ID. SUPPLIER: BC 公司 PRIMAX PART NO: 102100442030 PART NAME: Washer ADD'L INFO. G+HF+R2 SHIP TO. PRIMAX MI 廠 SFC Barcode Label Content Relationship of WMS P-Label and SFC label –Take below figure as example, the highlight color means the same data. SFC Label P-Label

33 2012/02/08 33 SFC Barcode Label Content Ex: One box contains 3 trays, tray is the smallest package, all the BOXID here are the same. Tray 1 Tray 2 Tray 3 SFC ID: 2900204451010001 BOXID: 2900204451010001

34 2012/02/08 SFC SMD Barcode Label Content Coding: Code 128 Label Size: Min 50*15mm Note: The rule of SFC SMD label is different from SFC label. SFC ID (Max. 40 digit) Primax Part No.(12~18digits) Supplier Short Name (ex. BC Electronic Co., LTD.  ”BC” or “BC company” are both acceptable) Min. 50mm Min. 15 mm

35 2012/02/08 SFC ID Coding Rule (for SMD) SFC ID (Max. 40 digits) PO No.(10 ) Item No.(3) Serial No.(3) Dash Q’ty(6) Dash Lot No(n) –The number rule of PO/ Item/SN is similar to WMS BOXID, but supplier could use previous/existed PO/Item for numbering. –Although the first 16 digits of SFC ID is similar to WMS BOX ID, it could be in-consistent to WMS BOX ID in the same box. –There is no “space” in front/back of “-”(dash). –The total digits of SFC ID depend on LOT NO. The maximum of total digits is equal or lesser than 40 digits. –LOT NO should be able to trace the manufactory information of supplier (maker). 1234 5 67891010 1 1212 1313 1414 1515 1616 1717 1818 1919 2020 21212 2323 n

36 2012/02/08 SFC ID Coding Rule (for SMD) SMD SFC ID coding example : –PO #: 2900012345 ; ITEM NO: 1 –PO Q’ty: 100K pcs –Reel Q’ty: 5K pcs/reel –LOT NO vs Q’ty LOT 120101— 20 K LOT 120108— 80 K –SFC ID goes to, 2900012345001001-005000-120101 ~ 2900012345001004-005000-120101 (4 Reels) 2900012345001005-005000-120108 ~ 2900012345001020-005000-120108 (16 Reels)

37 2012/02/08 How to get the latest file?


Download ppt "2012/02/08 1 Primax Confidential 1 Primax Barcode Label Requirement For All Primax Plants 2012.02.08 update (English version)"

Similar presentations


Ads by Google