Presentation is loading. Please wait.

Presentation is loading. Please wait.

Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Navy Rod Seal Testing Project Status as of 1 Sept 2002 Results from Rod Seal.

Similar presentations


Presentation on theme: "Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Navy Rod Seal Testing Project Status as of 1 Sept 2002 Results from Rod Seal."— Presentation transcript:

1 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Navy Rod Seal Testing Project Status as of 1 Sept 2002 Results from Rod Seal Testing Under Severe Conditions

2 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Testing Strategy Phase One – Seal Material Selection 1.Several seal configurations were evaluated at elevated temperatures against chrome plated rods (8-12 Ra) 2.Resulting materials should be good candidates for updating seals in actuators with chrome plated actuator rods Phase Two – HVOF Rod Coatings 1.Several HVOF surface coated rods will be evaluated against seals selected from Phase One under the same test conditions 2.Result is wear resistant surface coating with equivalent or better than chrome for seal service life

3 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Test Conditions Testing Details 1.Testing was performed in blocks of 16 hours 2.Temperature was 300°F (149°C) for first testing block and was reduced 25°F (14°C) for each subsequent block 3.Seals were cold soaked to 0°F (-17.8°C) between testing blocks to evaluate startup leakage 4.Internal pressure of the stand was connected to the drive actuator and varied constantly from 500 psi to 2500 psi (3 to 17 MPa) 5.Each hour consisted of 20 minutes of full strokes, 20 minutes of superimposed dither and 20 minutes of dither in place

4 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Test Conditions Full strokes- 3 ½ inches, 1 ½ second period

5 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Test Conditions Seal cavity was plumbed to drive actuator.

6 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Test Conditions Dither in place – ¼ inch, 4 Hz

7 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Seal Material Selection

8 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Seal Material Selection Seal Material Results 1.One vendor’s seals leaked early on and continued to leak suggesting a material or seal dimension problem 2.Nitrile and Improved Nitrile baseline seals have proven unacceptable in this test and in the field 3.Engineered elastomer configurations showed steady leakage with increased leakage during low temperature startup and some produced tar like sludge at the rod seal interface. 4.Several PTFE spring energized seals showed no measurable leakage throughout testing

9 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 HVOF Rod Test Plan HVOF Test Strategy 1.PTFE spring energized seals showed none of the elastomer related degradation (high temperature damage or low temperature startup leakage) 2.These seals are currently used in F/A-18 E/F, F-22, V-22 and JSF flight control actuators with excellent performance in dynamic applications 3.Seals selected for HVOF testing were damage resistant coil spring energized PTFE seals from two vendors

10 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 HVOF Test Rods Test Rods for HVOF Coating Endurance Test 1.Test rods were ordered using HVOF with Tungsten Carbide, Tungsten Carbide Chrome and Triballoy 400 finished to a coarse (8-12 Ra) and a fine (4-6 Ra) surface finish 2.Rods as received were much coarser than desired 3.Rods were installed with PTFE seals from two vendors and tested to Phase One stroking profile to evaluate rod surface wear and seal abrasion 4.Several of the rod/seal combinations completed the 100 hour test with no measurable leakage

11 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #1 WC/17Co Coarse Finish 20X 100X Surface Finish Ra9 13 12 Rz637987 Ry6794181

12 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #1 WC/17Co Fine Finish 20X 100X Surface Finish Ra5 4 7 Rz353155 Ry434767

13 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #2 WC/10Co4Cr Coarse Finish 20X 100X Surface Finish Ra666 Rz435143 Ry516751

14 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #2 WC/10Co4Cr Fine Finish 20X 100X Surface Finish Ra554 Rz283535 Ry315959

15 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #3 WC/17Co 0.010” Coarse Finish 20X 100X Surface Finish Ra797 Rz795951 Ry949859

16 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #3 WC/17Co 0.010” Fine Finish 20X 100X Surface Finish Ra666 Rz514351 Ry716771

17 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #4 Tribaloy T-400 Coarse Finish 20X 100X Surface Finish Ra171818 Rz276228220 Ry299287264

18 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod #4 Tribaloy T-400 Fine Finish 20X 100X Surface Finish Ra131612 Rz205220189 Ry287350248

19 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 HVOF Results

20 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Seal Material Selection

21 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod 1 Details Rod 1 Coarse Finish Both seals vendors developed early leakage against this surface Vendor 1 continued to leak at high rate Vendor 2 leakage corrected after 50 hours Rod 1 Fine Finish Neither seal showed significant leakage, but Vendor 1 seal showed steady minor leakage through testing Conclusion Fine finish seems easier on seal and produced less leakage through testing

22 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod 2 Details Rod 2 Coarse Finish Vendor 2 produced minimal yet steady leakage running against the coarse surface Vendor 1 produced no measurable leakage Rod 2 Fine Finish Vendor 1 produced minimal yet steady leakage and vendor 2 produced no measurable leakage Conclusions Vendor 1 appears to work better on the coarse finish Vendor 2 appears to work better on the fine finish

23 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod 3 Details Rod 3 Coarse Finish Vendor 2 seal produced minor but steady leakage against this surface Vendor 1 produced no measurable leakage against this surface Rod 3 Fine Finish Vendor 2 seal produced minor but steady leakage against this surface Vendor 1 produced minimal leakage late in testing Conclusions While both seals show acceptable performance, Vendor 2 seems more prone to leakage

24 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod 4 Details Rod 4 Coarse Finish Vendor 2 showed initial leakage against this surface and continued to leak through testing Vendor 1 developed steady minor leakage against this surface after 40 hours Rod 4 Fine Finish Vendor 1 produced little if any leakage Vendor 2 showed steady minor leakage through testing Conclusions Fine finish seems easier on seal and produced less leakage through testing

25 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Coarse Rods Steady Leakers Vendor 1 on Rod 1 and Vendor 2 on Rod 4 produced steady leakage through testing Vendor 1 Except on Rod 1, no Vendor 1 seals produced measurable leakage Vendor 2 Seals from vendor 2 developed early leakage that had tendency to correct later in testing Conclusions Vendor 2 seals were prone to initial leakage

26 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Fine Rods Steady Leakers Rod 4 finish was not a fine finish and both vendors’ seals produced steady leakage 2 other seals produced minor leakage during testing Minimal Leakage Several seals developed little if any leakage during testing Conclusions Fine finish seems less damaging to seals and produced less leakage during testing

27 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Vendor 1 Seals Rod 1 Coarse Finish Some condition caused premature failure of this seal Steady Leakers Two other seals with steady leakage were on fine rods Other Seals Most seals showed little if any measurable leakage through testing Conclusions Vendor 1 seal seems to perform better against a coarse surface finish

28 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Vendor 2 Seals Steady Leakage Many of the seals showed initial leakage that was corrected later in testing One seal on Rod 4 with very rough finish leaked steady through testing Fine Finish Two seals produced little if any measurable leakage against a fine rod surface Conclusions Vendor 2 seals are prone to initial leakage and appeared to perform better against a fine surface finish

29 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Leakage Summary Seal Performance Conclusions 1.Except for 2 installations, all seals performed significantly better than baseline Nitrile seals against chrome rod 2.Fine surface finish seems easier on seal and produced less leakage through testing 3.Vendor 1 appears to work better on the coarse finish 4.Vendor 2 appears to work better on the fine finish 5.Seals from vendor 2 developed early leakage that tended to correct later in testing 6.Leakage growth on HVOF rods was equivalent to leakage growth on chrome plated rods under these test conditions

30 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 20X Pre-Test Post-Test 100X Damage accumulated on chrome plated rod during 100 hour endurance test Typical Chrome Rod

31 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 20X Pre-Test Post-Test 100X After 100 hour endurance test, there is no visible surface damage on HVOF rod HVOF Rod 1

32 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 20X Pre-Test Post-Test 100X No visible damage to HVOF coated rod during 100 hour endurance test HVOF Rod 2

33 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 20X Pre-Test Post-Test 100X HVOF rod surface was comparable to pre-test conditions HVOF Rod 3

34 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Rod 4 (Tribaloy T-400) 20X Pre-Test Post-Test 100X Severe damage to rod 4 appears related to poor pre-test surface finish and shedding of material

35 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Summary Post-Test Observations 1.Chrome plated rods under these conditions developed longitudinal scratches resulting in external leakage 2.This is a common problem on chrome plated rods removed from aircraft actuators 3.Inspection of HVOF rods showed wear marks and polishing but the accumulated surface damage was much less severe than with chrome plated test rods 4.Rod 4 with Tribaloy 400 coating showed severe wear but this is believed due to galling on pre-test surface and continued material shedding 5.Initial surface finish is critical because wear resistant HVOF rods will not polish up in service

36 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Plan Ahead Based on these results, results from Viton GLT testing in 1996 and reports from Canada regarding Viton packed actuators currently in service, NAVAIR is planning to qualify F/A-18 actuators with: 1.Viton GLT AMS-R-83485 high temperature upgraded seals to replace current Nitrile static seals 2.Spring energized PTFE seals in primary and secondary positions to replace dynamic rod seals 3.We are also working with NADEP Jacksonville to qualify HVOF as a repair process for existing chrome plated actuator rods 4.Air Force has expressed interest in testing direct contact elastomer seals against HVOF rods

37 Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Reported Problem Problem Details 1.One commercial carrier in Europe has reported problems with premature seal wear and external leakage 2.Aircraft operated by same carrier with exclusive flights inside North America do not have this problem 3.Inspection of failed actuators identified selective leaching of the cobalt in the HVOF matrix leaving an abrasive spongy surface producing aggressive seal wear 4.Actuator vendor is actively investigating this problem but mechanism is not yet well understood 5.Believe de-icing fluid or some other solvent is the source of problems 6.Expect an update during the next SAE A-6 Fluid Power Committee meeting


Download ppt "Jeff Moorman Hydraulic Systems and Flight Control Actuators (301) 342-9373 Navy Rod Seal Testing Project Status as of 1 Sept 2002 Results from Rod Seal."

Similar presentations


Ads by Google