1 FG-1525 Glassbreak Sensor Training

2 Glassbreak Theory Basics
How does an acoustic glassbreak work?

3 Flex Signal Very low frequency sound
PANE OF GLASS Very low frequency sound Results from glass vibrating upon impact Similar to a drum head vibration

4 Audio Signal Mid- to High-frequency sound
PANE OF GLASS Mid- to High-frequency sound Results from glass shattering

5 Installation Basics Never exceed max range (25ft)
Mount on opposite wall or ceiling Install at least 6 ft from floor (to avoid blockage by furniture,etc.)

6 Installation Basics Always mount the sensor in direct line of site to the glass… e.g….an imaginary string tied to the detector should reach all points of the glass without bending. Always use the Tester for every installation

7 Installation Basics Selecting the Location
Clear view of glass to be protected At least 6.5 feet above floor At least 3.5 feet from forced air ducts At least 3.5 feet from sirens or bells Between the window and any heavy protective window coverings

8 Installation Basics Locations to Avoid Mounting
A corner On the same wall as the protected glass On free-standing pillars or posts In rooms with noisy equipment such as air compressors, bells, power equipment if the equipment will be operating while the sensor is armed

9 Introducing the FG-1525 Glassbreak Detector
FlexCore Signal Processing 25ft maximum range Adjustable sensitivity No minimum range Remote Test Mode Enable with FG-701 Protected PCB in all models

10 FlexCore Signal Processing
Parallel multiple tasking Faster than sequential processing (micro) Extracts over 50% more data in same time Faster, more accurate false alarm rejection

11 FG-1515 Glassbreak Detector
Same as FG-1525, except range is fixed at 15 feet

12 FGW-1525 Wireless Glassbreak Detector
Wireless-ready version of FG-1525 Uses 9V lithium battery Also, available as 5852 with complete 5800 transmitter

13 Installation Basics Design Features
Hinged cover twists off to improve access during wiring DETECTOR PARTS: 1 - Wire Entry Hole 2 - DIP Switches 3 - Terminal Blocks 4 - Breakout Flash (for cover screw) 5 - Latch 6 - Microphone 7 - Red LED 8 - Green LED 9 - Spacer Plate (Optional)

14 Installation Basics Mounting the Detector
Route the wires through the center wire entry port.

15 Installation Basics Wiring Connections
Wire as shown for Normally closed loop without EOL resistor.

16 Installation Basics Sensitivity Settings
MAX MED LOW LOWEST Sens1 Sens2

17 Installation Basics Sensitivity Settings
Mount the detector Start on Minimum sensitivity Test range using FG-701 simulator Adjust sensor sensitivity as needed Re-test range using FG-701 simulator

18 Installation Basics Using Remote Test Mode
Set FG-701 to “Activate” and “Man” Press “Red” button The “buzz” signal starts Test Mode Green LED will flash

19 Installation Basics Testing
Set FG-701 to “Test” and “Flex” Position tester near the glass Press “Red” button to prime the tester …

20 Installation Basics Testing
Aim FG-701 directly at detector Strike glass with cushioned tool (Flex signal) Tester will generate “Audio” signal Detector’s “Red” LED will light for successful test

21 Installation Basics Selecting Sensor Features
Latch LED

22 Types of Glass Covered UL and ULC Listed for: Plate Glass
Tempered Glass Laminated Glass Wired Glass Coated Glass Double Pane Sealed Insulated Glass

23 FG-1525 Proven Performance
The Facts about the Best Performing Glassbreak Detector in the World

24 FG-1525 Detection Verification
>50,000 glassbreak events All glass types with wide range of size/thickness Acoustic environment extremes Multiple ranges/angles from glass Multiple breaking tools

25 FG-1525 False Alarm Verification
51,120 false alarm events Acoustic environment extremes Most common, most difficult

26 Specific False Alarm Tests
Glass bottle on bottle Glass bottle on floor Full file cabinet drawer Empty file cabinet drawer Silverware in pot Silverware on floor 2x4 stud slapped together Hammer on nails Wooden door slam Pebbles on window Keys on window Coin tapped on glass Pot dropped on floor Pot dropped on pot Brass door knocker 2x4 stud dropped on floor Balloon pop Plastic bag pop Microwave door slam Kitchen cabinet door slam Chair dropped on floor Metal ladder dropped Broom dropped on floor Shovel dropped on floor Full cardboard box dropped Metal alarm box closed Dropped 1/4” plate glass Dropped 1/8” plate glass

27 FG-1525 False Alarm Tested Against the Best
HARD ROOM PRODUCT Position 1 Position 2 Sentrol SP3 89% 86% FG-1525 95% No one else comes close!

28 FG-1525 Proven Performance
Hands down the choice of ADT & Brinks Seamless introduction and acceptance in the field Over 81,400 shipped to National Accounts in 2000 !

29 Reviewing the FG-1525 Glassbreak Detector
FlexCore Signal Processing 25ft maximum range Adjustable sensitivity No minimum range Remote Test Mode Enable with FG-701 Protected PCB in all models

30 Introducing the FG-1508 Glassbreak Detector
FlexCore Processing 8ft max range (no min range) Adjustable Sensitivity Remote Test Mode Activation Built-in ValueGap Magnetic Contact

31 More FlexGuard Glassbreaks …Coming Q2 2001
FG-1508: 8ft detector with magnetic contact FG-1525R: Round case FG-1525F: Flush mount case, single gang FG-1525FD: Flush mount case, double gang FG-1525Z: Zone detector

32 Recessed Contacts Standard Models
Great idea!, but needs... Mini-screwdriver Lots of patience 2 aspirin

33 Staggered “T” Contacts
Same great idea!, but EASY! Uses regular screwdriver!

34 Staggered “T” Contacts
Staggered Terminals models 944T: 3/8” recessed 944TSP: 3/4” switch / 3/8” magnet 947-75T: 3/4” steel door switch 955PST: Plunger Switch 956RPT: Roller/ Plunger Packaged in Ammo Boxes

35 FG-1525 Glassbreak Sensor…
The best there is !


Download ppt "FG Glassbreak Sensor Training"

Similar presentations


Ads by Google