1 XMM 1 MOS2 CCD5 anomaly Status of the investigations.

2 XMM-Newton 2 Martin Stuhlinger, ESAC Detection of the problem Maite Ceballos and Jean Ballet discovered a large excess of counts <1 keV in MOS2 CCD5. Effect stops abruptly at about 1keV. Effect appears quite often. Jean Ballet informed ESAC. Rev. 891: MOS2 - 200-500 eV

3 XMM-Newton 3 Martin Stuhlinger, ESAC Facing the beast Out-FOV region MOS2 CCD5

4 XMM-Newton 4 Martin Stuhlinger, ESAC How to find other observations Compare CCD5 count rates with rates of other peripheric CCDs. Analyse out-FOV area to exclude effects of different sky regions (field sources) and backgrounds. Compare count rate ratios of individual CCD to the mean count rate to avoid wrong detections due to border effects of out-FOV area. Exclude 2 CCDs with highest count rates from mean count rate. Verify that this scheme is working correctly.

5 XMM-Newton 5 Martin Stuhlinger, ESAC Out-FOV border effects Rev. 919 MOS2

6 XMM-Newton 6 Martin Stuhlinger, ESAC Scanning the archive: MOS2

7 XMM-Newton 7 Martin Stuhlinger, ESAC Scanning the archive: MOS1

8 XMM-Newton 8 Martin Stuhlinger, ESAC Examples: MOS2 CCD5 + CCD2

9 XMM-Newton 9 Martin Stuhlinger, ESAC Examples: MOS2 CCD5 with 2 steps

10 XMM-Newton 10 Martin Stuhlinger, ESAC Examples: MOS1 CCD4

11 XMM-Newton 11 Martin Stuhlinger, ESAC Examples: MOS1 CCD5

12 XMM-Newton 12 Martin Stuhlinger, ESAC Triggered by high radiation?

13 XMM-Newton 13 Martin Stuhlinger, ESAC Triggered by high radiation? Unlikely!

14 XMM-Newton 14 Martin Stuhlinger, ESAC Search for correlation with HK parameter

15 XMM-Newton 15 Martin Stuhlinger, ESAC Conclusions MOS2 CCD5 effect is present from begin of the mission. (Short) phases in the past, continuously present since rev. 874. Effect also found in other CCDs of MOS1 and MOS2. So far no switch on/off detected within an observation. No occurrence of strange event pattern. No correlation with radiation monitors. Started to correlate with HK parameters. Perfect addition to the EPIC anomaly gallery.