Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux Comparisons.

Similar presentations


Presentation on theme: "Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux Comparisons."— Presentation transcript:

1 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux Comparisons

2 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux ratios as of SAS v5.1 Band E(keV) (M1 – M2)/M1 (M1 – PN)/M (75) (211) (205) (72) (73) (28) (28) (17) (14)

3 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux ratios - SAS v5.1 with correction for new optical axis positions Band E(keV) (M1 – M2)/M1 (M1 – PN)/M (170) (170) (413) (407) (232) (232) (132) (126) (39) (37) Sources with M1 counts > 250, inner 5 arcmins

4 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux ratios - SAS v5.4, latest QE with correction for new optical axis positions Band E(keV) (M1 – M2)/M1 (M1 – PN)/M (170) (167) (413) (407) (239) (235) (132) (126) (39) (37) Sources with M1 counts > 250, inner 5 arcmins

5 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Flux ratios - SAS v5.4, latest QE with correction for new optical axis positions Band E(keV) (M1 – M2)/M1 (M1 – PN)/M (170) (170) (413) (407) (239) (235) (132) (126) (39) (37) Sources with M1 counts > 250, inner 5 arcmins Band (M2-PN)/M NB: The band 1 PN fluxes reported at the meeting hadn’t been corrected for the change to using pattern 0 only in the pipeline. Corrected values are much closer to the MOS.

6 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC HWHM: M1/M2=6% M1/PN=14% Band 2 on-axis flux ratio distributions

7 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC HWHM: M1/M2=18% M1/PN=17% Band 2 off-axis flux ratio distributions

8 Epic-Cal 4 Feb 2003 Flux check Richard Saxton XMM-SOC/SSC Summary Mos-2 and PN broad-band fluxes agree to better than 5% at all energies. Mos-2 and PN broad-band fluxes agree to better than 5% at all energies. Mos-1 over-predicts PN by 4-8% above 2 keV Mos-1 over-predicts PN by 4-8% above 2 keV and Mos-2 by ~4% higher flux above 4.5 keV – possibly and Mos-2 by ~4% higher flux above 4.5 keV – possibly needs a further QE tweak needs a further QE tweak The Mos-1/Mos-2 distribution gets significantly wider off- axis The Mos-1/Mos-2 distribution gets significantly wider off- axis The Mos-1/PN distribution has a sigma 2.5 times The Mos-1/PN distribution has a sigma 2.5 times wider than that of the Mos-1/Mos-2 distribution. wider than that of the Mos-1/Mos-2 distribution..