Download presentation
Presentation is loading. Please wait.
1
XMM-Newton 1 M.Stuhlinger/M.Smith, ESAC PN Monitoring Mallorca, November 2007
2
XMM-Newton 2 M.Stuhlinger/M.Smith, ESAC Hot Pixels Mainly Column 64 Hot Pixels M. Smith
3
XMM-Newton 3 M.Stuhlinger/M.Smith, ESAC Noisy Pixels Decrease in number of Noisy Pixels due to modified blanking of Column 64 segments in latest BPT update (Rev 1408 onwards) M. Smith
4
XMM-Newton 4 M.Stuhlinger/M.Smith, ESAC EPIC Telemetry M. Stuhlinger
5
XMM-Newton 5 M.Stuhlinger/M.Smith, ESAC Offset Median Increase in offset median: 2 – 5 ADU for Q0 CCDs since ~ Rev 1410 Perhaps other CCDs also, e.g. CCD5 Coincides with latest PN BPT implementation (Rev 1409); however, the changes in the BPT affected CCD11 only… Similar to onset of the offset median trend seen in Revs 605 – 660 M. Smith
6
XMM-Newton 6 M.Stuhlinger/M.Smith, ESAC Offset Median (cont.) Regarding the Rev 605 – 680 offset median trend: A correlation was found with the respective Quadrant VC Currents (params F1189-92) (discussed at the Saclay 2003 Ops Meeting)… J. Fauste, S. Rives M. Smith
7
XMM-Newton 7 M.Stuhlinger/M.Smith, ESAC Offset Median (cont.) F1189: Q0 VC Current …however, in the recent trend: NO correlation with VC Current found. G. Buenadicha, P. Calderon M. Smith
8
XMM-Newton 8 M.Stuhlinger/M.Smith, ESAC Offset Variance First Observations per Revolution Eclipse Season Boundaries Behaviour still not understood M. Smith
9
XMM-Newton 9 M.Stuhlinger/M.Smith, ESAC M. Kirsch Energy Scale vs Time very good, esp. for FF mode. Slight over-correction for EFF mode. SW mode under- correction, esp. at Mn (Result of SAS 7.1 Processing)
10
XMM-Newton 10 M.Stuhlinger/M.Smith, ESAC M. Kirsch Line width trend is stable ~0.5 ADU/year increase at Mn (Result of SAS 7.1 Processing) M. Kirsch
11
XMM-Newton 11 M.Stuhlinger/M.Smith, ESAC MOS Monitoring Mallorca, November 2007
12
XMM-Newton 12 M.Stuhlinger/M.Smith, ESAC MOS1 Bad Pixels MOS2 Still fewer Bad Pixels than before cooling Nevertheless, steadily increasing trend for most CCDs M. Smith
13
XMM-Newton 13 M.Stuhlinger/M.Smith, ESAC New MOS fixed offsets from Rev. 1400 onwards. MOS fixed offsets lowered by 1 ADU for: - MOS1 CCD 5 - MOS2 CCDs 1, 2, 3 and 6 M. Smith
14
XMM-Newton 14 M.Stuhlinger/M.Smith, ESAC M. Stuhlinger
15
XMM-Newton 15 M.Stuhlinger/M.Smith, ESAC MOS1_Al_width.ps M. Stuhlinger
16
XMM-Newton 16 M.Stuhlinger/M.Smith, ESAC M. Stuhlinger
17
XMM-Newton 17 M.Stuhlinger/M.Smith, ESAC Low Energy Noise (MOS2CCD5-Effect): MOS2 MOS1
18
XMM-Newton 18 M.Stuhlinger/M.Smith, ESAC Low Energy Noise (MOS2CCD5-Effect):
19
XMM-Newton 19 M.Stuhlinger/M.Smith, ESAC Due to Charge Injection? RAWY ~40
20
XMM-Newton 20 M.Stuhlinger/M.Smith, ESAC Charge Injection Spectra along RAWY
Similar presentations
© 2024 SlidePlayer.com Inc.
All rights reserved.