1 Keith Legg 847-680-9420 Summary of coating integrity and planned testing HCAT Program Review August 2001 Toronto

2 Keith Legg 847-680-9420 Big bar tests at NAWC, PAX River n #6, R= -1, WC-Co 0.012” ä Failed at 180 ksi n #2, R= -0.33, WC-Co 0.012” ä Test 1 180 ksi 20 cycle  Failed at 200 ksi n R= -1, WC-Co 0.003” ä Passed 220 ksi #6 #2 Very sensitive to thickness. Insensitive to R Very sensitive to thickness. Insensitive to R Big bars not much different to small

3 Keith Legg 847-680-9420 Hill AFB re-optimization WC-Co looks good to 240 ksi, R=-0.5 Note failures at higher substrate T, lower dep rate WC-CoCr WC-Co, 3 pts WC-Co fail We can make 0.005”, 0.015” WC-Co coatings that do not spall at 240 ksi, R=-0.5

4 Keith Legg 847-680-9420 Latest data from 40 specimens coated at Southwest Aero, 0.003”, 100 cycles at each load to 240 ksi S max @ R=-0.5 M5-7, WC-CoCr fullM5-17, WC-CoCr patch M5-28, WC-Co patch M5-37, WC-Co full 190Subsurface*SubsurfaceNone 200Crack @ 51 cyclesSubsurfaceNoneSubsurface & bulging** 210Crack, no spallingCrack @ 60 cyclesCrack @ 85 cycles, some subsurface Same 220Crack, no spalling Same 230Crack, no spalling Crack, some bulging** Same 240Nf=3046 cycles, spalling @ fracture Nf=3004 cycles, spalling @ fracture Nf=3368 cycles, spalling Crack @ 72 cycles, Nf=3716 cycles WC-CoCr survived to 240 ksi and exceed Nf Does this mean WC-CoCr is not a lot more brittle than WC-Co? WC-CoCr survived to 240 ksi and exceed Nf Does this mean WC-CoCr is not a lot more brittle than WC-Co?

5 Keith Legg 847-680-9420 Ogden ALC A-10 LG bend tests, R=-0.33 0.010” WC-Co deposited at OO-ALC using new parameters  500 cycles at loads to 190 ksi  ultrasonic tests showed no delamination  50 cycles at loads >190 ksi  no spalling at 240 ksi (yield)  coating spalled at 256 ksi (>yield) 0.015” WC-Co  spalled at low load - cause unknown We can reach 240 ksi with thick coating Is spalling very sensitive to thickness? We can reach 240 ksi with thick coating Is spalling very sensitive to thickness?

6 Keith Legg 847-680-9420 Conclusions to date WC-Co and WC-CoCr can both exceed commercial requirements for OEM coatings (0.003”) WC-Co can exceed Air Force (land-based aircraft) requirements for rebuild coatings Spalling appears most sensitive to  deposition conditions (how it is optimized)  coating thickness Spalling appears not very sensitive to  sample diameter (details of coating morphology)  R ratio (once you get interface cracking it does not need a big push to delaminate) WC-Co looking likely to work for all but high-bend parts

7 Keith Legg 847-680-9420 Work to be done Additional testing  Additional samples and big bar tests at NAWC  New samples and big bar tests at Metcut and AFRL  Bend tests to examine D/T ratios at Hill  Additional A-10 bend tests at Hill  Bending fatigue of large cylinders at Goodrich Process mapping  Coatings can exceed requirements - let’s make sure we know how to ensure they always do! Consideration of rebuild options  Ensure coating integrity through deposition control  Duplex coatings (alloy build-up, carbide cap)  e.g. Long Beach Joe Kolek reported Tribaloy does not crack - is it a good rebuild, or is NiAl better (cc sulfamate Ni)?