Personnel decontamination procedures Lesson topic 4.6.

Similar presentations


Presentation on theme: "Personnel decontamination procedures Lesson topic 4.6."— Presentation transcript:

1 Personnel decontamination procedures Lesson topic 4.6

2 Enabling objectives ¶Discuss decontamination procedures on gloves, mask, face and mask interior using M291 decontamination kit ·Describe the procedures for transiting personnel through a decontamination station and contamination control area

3 ¸Describe the equipment used on transiting personnel through a decontamination station and contamination control area ¹Describe the use and contents of the M291 decontamination kit Enabling objectives

4 M-291 Skin Decontamination Kit zDecontaminate skin by physical removal, absorption and neutralization of the agent on the skin CAN BE USED TO DECON MASK & GLOVES DURING EMERGENCY CONDITIONS

5 M-291 zContents y6 hermetically sealed foil packets yEach packet contains a folded non-woven fiber applicator pad yApplicator pad is impregnated with a reactive & absorptive resin mixture

6 M291 skin decon kit

7 zTwo packets covers a minimum of 1300 square centimeters or 200 square inches of exposed skin zWallet-like carrying pouch zDecontamination of liquid chemical agents zProcedures must be done quickly, 3 minutes or less M-291

8 M291 zInspection yInspect kit for black powder yInspect each packet for leaks yDiscard all leaking packets IF THERE ARE LESS THAN 4 PACKETS IN YOUR KIT, REQUEST ADDITIONAL PACKETS

9 M291 zOperating procedures FOR EXTERNAL USE ONLY If you suspect you have been contaminated & don your mask are not masked, don your mask!!!!

10 zRemove 1 packet from pouch zRemove applicator from packet zSlip finger(s) into handle and scrub hands thoroughly M291

11 z2 PACKETS MAY BE REQUIRED TO COMPLETELY DECONTAMINATE ALL EXPOSED SKIN z3 TO 6 SKIN DECON PROCEDURES CAN BE SUPPORTED BY ONE KIT

12 Suspect your face is contaminated zHold breath, close eyes & lift mask from chin zDecon lower part of face & decon interior surface of mask that touches face zSeal & clear mask zRemove second packet & scrub neck/ears zRepeat decon of hands zPut on protective gloves & don hood

13 If you suspect agent on your skin & are already masked zPull hood down zScrub hands, neck & ears zRe-do hands zPut on protective gloves & don hood

14 Contamination Control Area (CCA)/Decontamination Station (DS) zRestrict spread of contamination zCCA located just inside skin of ship zIf suitable interior space is unavailable use an area outside

15 Criteria for CCA zSet-up yDivide the area into two approximately equal parts yMark the three positions zSupplies yCalcium Hypochloride (HTH) yM-291 Kits yBandage scissors

16 Manning z1 team leader z2 DC/HT operators/cutters z1 medical corpsman or an equivalent

17 Operation zOutside the CCA yDecon your buddy's mask & your own gloves yYour buddy repeats the procedure y1% solution of HTH may be used on mask yBefore entering the CCA, step into a pan of 9% HTH solution and scrubs boots

18 CCA/Decon station zInside the CCA yFollow ACPG doffing procedure zInside decon station yRemove clothing except the mask yProceed to the shower yProceed to the redressing area yUse 9% HTH/salt water followed by detergent scrubbing if the CCA becomes contaminated

19 Un-masking procedures zUpon appropriate un-mask order yIndividual personnel will doff mask as follows yPlace a plastic bag over your head & mask yHands on the outside of the plastic bag, carefully remove the bag with the mask yReturn mask in the bag to a designated collection point for sanitation/reissue

20 Summary and Review zM-291 Decontamination Kit zContamination control area (CCA) zDecontamination Station (DS)