1 Tintometer GmbH Products Water Analysis

2 Overview Lovibond® Products
Titrimetric methods MINIKIT Colorimetric methods Comparators (CHECKIT and 2000+) Photometers (MD 100 (Boiler and Cooling Water), MD 200, MD 600, MultiDirect and SpectroDirect) Biochemical Oxygen Demand (BOD) BD 600 Thermostatically controlled incubators Chemical Oxygen Demand (COD) Thermoreactor RD 125 Electrochemistry SensoDirect Serie (Oxi200, SensoDirect 150) SD-Serie (SD 320, SD 300, SD 50, SD 60, SD 70, SD 80, SD 90) Turbidity TB 300 IR, TB 210 IR and TB 250 WL Floc-Testers

3 Titrimetric methods MINIKIT Easy operation and exact reagent dosing
High accuracy Foil-wrapped Lovibond® tablet reagents with a minimum guaranteed shelf life of 5 years Unrestricted shipment Safe storage

4 Arsenic Test Kit Easy to handle
Highly sensitive according to WHO requirements (0.005 mg/l Arsenic detectable) Resolution: mg As3+/5+ Closed reaction vessel to not harm the user by arsine gas escape Removal of the interfering sulfide ions is integrated in the test procedure. Complete in a carrying case, ready to use Applications Drinking Water Use in the field or laboratory

5 Colorimetric methods CHECKIT Comparator
Handy and reliable colorimetric measurement system Different Checkit®Discs for different parameters and measurement ranges available Continuous colour scales to achieve an exact colour match between the colour standard and the sample Using long time stable Lovibond® tablet reagents

6 Colorimetric methods Comparator 2000+
Visual test systems for a range of water analysis applications Colorimetric measurement system 400 different colour discs for different parameters or measurement ranges available Long time colour stable Lovibond® glass standards Daylight unit with rechargeable battery Cell holder up to 40 mm path length

7 Lovibond® Photometer MD 600 SpectroDirect MD100 MD 200 MultiDirect

8 Colorimetric methods Photometer MD 100 and MD 200
High quality interference filters Accurate, reproducible results Very quickly Compact dimensions Storage function Data transfer One Time Zero (OTZ) Single and Multi Parameter Reference Standard Kits for Chlorine and pH Verification Standard Kit

9 MD 100 Boiler and Cooling Water
Colorimetric methods MD 100 Boiler and Cooling Water Boiler Water Aluminium, Chloride, Copper, DEHA, Hydrazine, Iron, Oxygen, Phosphate, Polyacrylate, Silica Cooling Water Aluminium, Bromine, Chlorine LR and HR, Chlorine dioxide, Copper, Iron, Molybdenum, Ozone, Sulfate, Triazole, Zinc

10 Colorimetric methods Photometer MD 600
Combines the mobility of a portable photometer with characteristics of a modern laboratory photometer Wide range of preprogrammed methods (> 120 methods) 35 user defined methods Updates of new methods via Net Compact dimensions Memory for 1000 data sets Data transfer Verification Standard Kit

11 Photometer MultiDirect
Colorimetric methods Photometer MultiDirect Dual Beam Technology Interference filters for highest accuracy Wide range of pre-programmed methods Update of new methods via Net Interface Mobile Graphic Display Rechargeable batteries (recharged within device) Memory for 1000 data sets Verification Standard Kit

12 Photometer SpectroDirect
Colorimetric methods Photometer SpectroDirect Single beam spectral photometer Wavelength range: 330 to 900 nm Self-test Multifunctional sample chamber (16 and 24 mm round vials; mm rectangular cells without adapter) User prompt in the display (different languages available) Spectral data, wavelength scan over user-defined interval

13 Biochemical Oxygen Demand (BOD) – BD 600
User friendly Large brilliant graphic display Graphical representation of measured values Bluetooth, USB & SD Card Interface Manometric measurement system Selectable measuring period days (BOD5, BOD7, OECD...) Result memory for up to 28 days Measuring ranges from mg/l to mg/l Ecologically friendly (mercury-free) Automatic Start function Test set for BD 600 available

14 Biochemical Oxygen Demand (BOD)
Thermostatically controlled incubators (TC series) Temperature from 2 °C to 40 °C Regulate in steps of 0.1 °C Temperature tolerance: ± 1 °C, specified for a stirred 500 ml water sample (for BOD, T = 20 °C : ± 0.5 °C) Volume 135 to 445 liters Optional glass door Various applications e.g. BOD, microbiological testing, storage of water samples

15 Chemical Oxygen Demand (COD)
Waste water parameter Complete COD-Measurement Set-up (Tubes, Thermoreactor and Photometer) Accurate and easily performed determination of Chemical Oxygen Demand COD vario vial tests are available for 3 measuring ranges: mg/l O2, mg/l O2, mg/l O2 ST-COD sealed tubes ready for use

16 Chemical Oxygen Demand (COD)
Thermoreactor RD 125 24 holes Selectable temperature: 100, 120 and 150 °C Temperature stability: ± 1 °C Selectable Time: 30, 60, 120 min and conti mode For the Tube test digestion of: COD TOC Total Chromium Total Nitrogen Total Phosphate

17 Lovibond® Reagents for Water Testing
Tablets Tube tests VARIO Powder Liquids

18 Lovibond® Tablet Reagents
Long shelf-life (up to 10 years) Accurate dosing and accurate test results Minimized health risks Low transportation costs

19 Lovibond® Liquid Reagents
Limited shelf life Easy dosing dropwise Easy dissolving Limitation of bottle size DPD liquid in three bottles

20 Lovibond® Powder Reagents
Long shelf life (5 years) Easy dosing Improved packaging Low transportation costs

21 Powder Dispenser DPD Method (Vario)
For Free and Total Chlorine testing according ISO :2000 Range mg/l Free Chlorine mg/l Total Chlorine Sample size 10 ml 250 tests / reagent vials Shelf life: 5 years (reflects unopened ampulle, use material within 6 months of removing the seal)

22 Lovibond Tube Test Prefilled reagent tubes
According international standards Hazardous chemicals Combination powder – test tubes 16 mm tubes Suitable for many instruments COD, Nitrogens, Phosphorous, etc.

23 Electrochemistry SD 300 pH, SD 320 Con
High resolution (0.001 pH/0.1 mV) Rugged, water resistant Designed for field use Automatic temperature compensation Automatic buffer detection for calibration PC interface for data transfer (USB / serial or analog) Data logger Backlit LCD display

24 Electrochemistry SensoDirect Oxi200 Easily handled
Water and shock-proof Hold-function Automatic temperature compensation Oxygen partial pressure/oxygen concentration/ oxygen saturation, temperature measurement; no polarization period needed easy calibration against oxygen in air

25 Electrochemistry SensoDirect 110 Light weight Protective casing
Large digital display “Low battery” indicator Two point Calibration

26 Electrochemistry SD Series Portable Hand-Held Meter
scroll-Through Functionality Compact & Robust storage Function Backlit Display Waterproof

27 Lovibond® Turbidity Meter
TB 210 IR TB 300 IR TB 250 WL

28 Turbidity Principle of Turbidity Measurement

29 Turbidity TB 300 IR, TB 210 IR and TB 250 WL
TB 300 IR, TB 210 and TB 250 WL: laboratory and field use Infrared light source for colourless and coloured samples TB 250 WL with white light source Range: NTU Complete unit including accessories and calibration standards

30 Floc Testers Continuously variable stirring speed Digital display
Timer feature Height adjustment of the stirring plates during operation Type ET 730 portable, for use in the field or laboratory applications