Presentation is loading. Please wait.

Presentation is loading. Please wait.

Trelleborg Protective Products AB

Similar presentations


Presentation on theme: "Trelleborg Protective Products AB"— Presentation transcript:

1 Trelleborg Protective Products AB
Trellchem Escape Chemical Oxygen Breathing Apparatus

2 Closed circuit chemical oxygen breathing apparatus
Chemical Oxygen Set Closed circuit chemical oxygen breathing apparatus Approved and CE marked October 2, 2008

3 The Trellchem Escape Family of Products
Escape 10 – Escape set Escape 15/CSRE – Working/Rescue set Approvals: CE 120 (EC Directive 89/686EC) ATEX Directive 94/9/EC Benefits: Automatic Start Quick & Easy to Fit Lightweight Built in Alarm Custom Packaging Freedom of Movement Ease of Training October 2, 2008

4 Chemical Oxygen Set Hood Visor Breathing & Reservoir Bag Oronasal Mask
Alarm Visual Indicators Chlorate Starter Candle Speech Device KO2 Generator Pocket © Semmco Limited 2009

5 HEAD Set – Carry Case Bandolier Carry Case
Semi-rigid PVC construction, with security tag and integrity window, presented in a highly visible yellow (Escape) or blue (Inspector/Working) case with printed donning procedure and shoulder strap. © Semmco Limited 2009

6 Escape 15 – Size & Weight Size: Length: 335mm (approx)
Width: 300mm (approx) Depth: 165mm (approx) Weight with case: 3 kg (approx) Weight without case: 1.6kg (approx) © Semmco Limited 2009

7 Escape 10 - Size & Weight Size: Length: 330mm (approx)
Width: 190mm (approx) Depth: 140mm (approx) Weight with case: 2.4 kg (approx) Weight without case: 1.5kg (approx) © Semmco Limited 2009

8 Escape 10 Set – Wall Mounted
Wall Mounted Case Rigid plastic construction, with security tag and integrity window, secured to wall via metal strap with printed donning procedure on the front of the case. © Semmco Limited 2009 8

9 Escape 10 Set WM – Size & Weight
Length: 310mm (approx) Width: 210mm (approx) Depth: 160mm (approx) Weight with case: 3.3 kg (approx) Weight with outcase: 1.5kg (approx) © Semmco Limited 2009 9

10 How Does it Work? HEAD Set utilises “chemical oxygen”, Potassium Superoxide (KO²), to generate oxygen and allow carbon dioxide (CO²) to be removed. The initial start up phase incorporates a chlorate candle that is activated as the set is donned and the self-test alarm procedure. The wearer exhales through the generators so commencing the generation of oxygen and removal of CO². © Semmco Limited 2009

11 Initial start-up phase, Alarm initiation – LED’s pulse
sounder beeps 5 times © Semmco Limited 2009

12 Chlorate candle releasing oxygen into reservoir bag
© Semmco Limited 2009

13 First exhalation breath activating KO2 (Potassium Super Oxide)
© Semmco Limited 2009

14 Dwell period between exhalation and inhalation
gases mix in reservoir bag © Semmco Limited 2009

15 Inhalation with pure oxygen,
CO2 removed © Semmco Limited 2009

16 reacting with KO2 producing
Exhalation breath reacting with KO2 producing oxygen and removing CO2 © Semmco Limited 2009

17 Alarm Is Initiated - Intermittent: at 2/3 duration.
Continuous: at 10 minutes (HEAD6&10) and 15 minutes (HEAD15/CSRE). © Semmco Limited 2009

18 HEAD Set – Components Hood:- Incorporating the oronasal mask harness and the generator cells cradle. This arrangement allows the mask and hood to be positioned for maximum wearer comfort and safety. The hood visor provides excellent panoramic vision and easy sight of the visual alarm indicators. The comfortable latex neck seal ensures protection to the wearer from irrespirable atmospheres. © Semmco Limited 2009

19 HEAD Set – Components The warning alarm:- The warning alarm provides the user with a three stage audible and visual alarm. Stage 1:- The warning alarm will function briefly to confirm operation on start up. Stage 2:- which is initiated after 2/3 of the effective duration, provides the wearer with an intermittent visual and audible alarm. Stage 3:- activates when the effective duration has been reached, providing the wearer with a constant audio and visual alarm. © Semmco Limited 2009

20 HEAD Set – Components Generator cells:- Containing Potassium Superoxide (KO²). Ideally located on either side of the wearer’s head, ensuring an even distribution of weight whilst maximising the breathing system’s efficiency in the generation of oxygen and the removal of carbon dioxide. © Semmco Limited 2009

21 HEAD Set – Components Breathing bag and chlorate candle:- Located at the rear of the hood which also incorporates the breathing circuit over- pressure relief valve, completing the breathing circuit. © Semmco Limited 2009

22 How are HEAD Sets Packaged?
HEAD Sets are vacuum-sealed in an aluminium foil container. An indicator provides the user with a simple visual check on the integrity and condition of the unit. This novel packaging system allows the unit to be stored for an initial six years and for a further three year period following a satisfactory validation/re-certification test. © Semmco Limited 2009

23 HEAD Sets - Prior to use Check Case To Ensure:
The case is not damaged. The security seal is intact. The unit is within life expiry date. The vacuum pack is intact and the indicator is BLUE.If indicator is PINK, DO NOT USE! The equipment should not be used if these conditions are not met. © Semmco Limited 2009

24 HEAD Sets – Donning Open the carrying case by pulling webbing tag. OR
Open the wall mounted case by pulling on the lid. Lid will fall away to reveal vacuum pack. Unfold tear strip, hold securely and rip open using red tear tab. Pull firmly on the breathing protection device to remove from vacuum pack. This action automatically activates the generation of oxygen into the breathing bag and commences the alarm start up procedure. If the alarm self test procedure does not initiate do not use the set. © Semmco Limited 2009

25  Open the carrying case by pulling webbing tag.
Donning  Open the carrying case by pulling webbing tag. © Semmco Limited 2009

26 Donning  Lid will fall away to reveal vacuum pack. Unfold tear strip, hold securely and rip open using red tear tab. © Semmco Limited 2009

27 Donning Pull firmly on breathing device to remove from packaging. At this point oxygen generation and alarm self test automatically start. Check inside case for bungs, firing pin and alarm tag. © Semmco Limited 2009

28 Donning  Unfold hood, place fingers inside the neck seal, inhale and pull over head. Hold front port and adjust position of oronasal mask to ensure correct fit, comfort and field of vision. Exhale breath and commence normal breathing. © Semmco Limited 2009

29 Donning Ensure latex neck seal is not compromised by clothing or long hair. Buddy check.  Carry out your activity. When the warning device activates in the constant mode, HEAD indicates that oxygen generation may be ending. © Semmco Limited 2009

30 Donning - WM © Semmco Limited 2009 30

31 Doffing WARNINIG :- DO NOT REMOVE HEAD SET UNTILL YOU ARE IN A KNOWN SAFE ENVIRONMENT NEVER RE-USE A PART EXPIRED HEAD SET ALLOW SET ALARM TO “TIME-OUT” BEFORE PACKING FOR RETURN © Semmco Limited 2009

32 HEAD SET – Return The used HEAD Set must be double bagged and packaged along with its Carry Case / Wall Mount Case, and returned to Semmco for rework via your approved route. © Semmco Limited 2009

33 Practical Training Training Set – Orange DUMMY STARTER
DUMMY GENERATORS SIMPLIFIED AIR FLOW NO ALARM – SEPERATE TRAINING AID SIMULATED VAC BAG EASY CLEAN © Semmco Limited 2009

34 Periodic (monthly) & before donning inspection
The case is not damaged The security seal is intact. The unit is within the life expiry date. The vacuum pack is intact and the indicator has not turned pink. The equipment should not be used if these conditions are not met !! © Semmco Limited 2009

35 Key Benefits Quick & easy to fit Lightweight Built in alarm
Automatic start Quick & easy to fit Lightweight Built in alarm Very high levels of protection Clear voice communication Allows freedom of movement Ease of training Nil through life service costs Nil support equipment required © Semmco Limited 2009


Download ppt "Trelleborg Protective Products AB"

Similar presentations


Ads by Google