Presentation is loading. Please wait.

Presentation is loading. Please wait.

BFM136 Branch Feeder Monitor April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Similar presentations


Presentation on theme: "BFM136 Branch Feeder Monitor April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality."— Presentation transcript:

1 BFM136 Branch Feeder Monitor April 2011

2 SATEC 25 years of Innovation in measurement & management of Energy and Power Quality

3

4 RS232/422/485, Profibus, TCP/IP, Dialup modem, GPRS, RF Modbus RTU, ASCII, DNP3.0, Modbus/TCP, DNP3/TCP, IEC 61850 LAN eXpertpower™ Server (Pro Edition) Multi-Tenant Submetering Power Measurement Energy Efficiency & Cost Allocation Energy Management & Billing Asset Management Substation Automation Power Quality Analysis Fault Recording Revenue Metering Smart Grid & Demand Response Internet eXpertpower™ Server (SaaS)

5  Multi-tenant energy meter  Multi-point power measurement  Data logging BFM136  Monitors up to 12 three phase channels or 36 single phase channels, or any combination between them.  Monitors: energy, demand, data logging, power quality and multi-tariff (TOU). Branch Feeder Monitor - Multi-Tenant Energy Meter

6 BFM136 Before Now Branch Feeder Monitor - Multi-tenant energy meter

7 BFM136 Branch Feeder Monitor - Multi-Tenant energy meter  Provides a complete set of energy and demand data on multi-tariff basis for billing purposes  Class 0.5S precision in revenue metering  Meter sealing option for voltage and current inputs  Current and voltage monitoring –12 3-phase channels –18 2-phase channels –36 1-phase channels –Any combination of the above  Compliant with ANSI and IEC specifications  LCD display for on-site access, providing 30 channels of consumption readings for each tenant  Data access and TOU via PAS software  Compact design for easy installation within existing or new electric panel  Durable design for tamper resistance  Communication platforms –Built-in serial RS485; –Optional: modem, Ethernet, wireless

8 BFM136 Branch Feeder Monitor - Multi-Tenant energy meter  TCP Notification Client  Event and data logging  Flash memory 8 Mb  Data access: –LCD display –PAS – Power Analysis Software –eXpertpower™ - Internet access to data, from anywhere, anytime.  Reliable data storage: Flash memory for integration with interval data and Time-of-Use (TOU) capability  High accuracy: complies with ANSI C12.16 and IEC62053-21 (IEC1036). The accuracy if for the device and the CTs together.  Multi-client billing: provides the entire range of data for all billing purposes  Multi-circuit energy reading  Multi-point energy demand data logging

9 Large Selection of CTs  Supplied with cables for easy installation  Accuracy class 0.5A includes the meter and the CT (other meters are 0.5% meter, 0.5% CT, total of 1%)  Ranges from 100A to 400A  Standard or split cores

10 Typical Applications  Multi-tenant facilities –Office buildings –Shopping malls –Residential projects  Industrial facilities  Service facilities –Hospitals –Old age homes  Utilities

11

12 Software Solutions  PAS – Power Analysis Software  eXpertpower™ - Internet access to data, from anywhere, anytime.

13 PAS setup and application tool for all SATEC’s Instruments Power Analysis Software's versatility:  Automatic power quality reports for EN50160 & IEEE 1159  Automatic polling of devices  Simple off-line instrument setup  Direct data access for status monitoring or analysis  Communication: RS standard serial lines, TCP/IP, USB, Telephone/Modem  Analysis (see detailed list)  Self-test  Easy export to spreadsheet, Word, Excel or database  Extensive graphic and report capabilities for waveforms, harmonics & billing  Export COMTRADE (IEEE standard common format for transient data exchange)  Export PQ

14 PAS Analysis:  Data logs—historical or current  Trends—individual or 3 phases together  Trend over time data log or waveform  Trend based on user-selected parameters or limits  Harmonic spectrum  Harmonics power direction  EN50160 comparison tables for HV and LV applications  G5/4 comparison tables for HV and LV applications  Vector analysis/phasor diagram  Automatic power quality and fault categorization  Waveform comparison between sites  ITI (CBEMA) curve  Automatic sort and filter capabilities  Uploading TOU settings  Uploading with variable setpoints  Alarms with variable setpoints  Delta measurement setup and application tool for all SATEC’s Instruments

15  Present Information, Control operations and Makes strategic decisions Web-based - Energy Management System eXpertPower TM  Data are highly accessible and presented to facilitate decisions

16 eXpertPower TM  Collects data from meters  Analyzes the data  Presents the information using: –Standard Data Displays –Graphical Presentations –Interactive Graphs –Export Tools  Reacts ! Web-based - Energy Management System

17 eXpertPower TM  Data Monitoring and Recording  Navigation  Data Views  Reporting capabilities  Events and Alarms Web-based - Energy Management System Lite  Energy Consumption Monitoring  Cost Calculation & monitoring  Data Presentation Savings

18 eXpertPower TM Web-based - Energy Management System BillingPro  Cost Calculation & monitoring  Invoice management  Tenant Management  Additional costs  Listing and display of various Power Quality events  Event Summary  Waveform display and analysis  EN50160 Standard Support

19 eXpertPower TM - Lite Data Monitoring and Recording  Over the web monitoring  Reads all models of SATEC meters; Configurable to support any MODBUS devices  Support of complimentary data by reading digital inputs, analog inputs and PLCs  Data polling from any number of meters  Customized parameter definition for optimization of network resources  Flexible scheduling and prioritizing of readings per meter Navigation  Default device representation or customized graphic navigation pages  Intuitive linking between current readings, history and trends Web-based - Energy Management System

20 eXpertPower TM - Lite Data Views  Last reading screen represents device display  History pages grouped by data types: per phase, energy, totals and harmonics  Graphs include:  Zoom-in/zoom-out  Display exact values at chosen points  Choice of 1-3 phase display  Direct links to relevant tables Reporting capabilities  Export to.xls and.csv format  Devices included in report by user's choice  Historical reports Events and Alarms  Predefined and user-defined events recorded  Event view filter by wide range of parameters (time, event type, device etc)  Alarm definition supports emails and SMSs Web-based - Energy Management System

21 eXpertPower TM - Savings Energy Consumption Monitoring  Energy consumption calculations for one or more monitored points  TOU Calculation  Multi resolution Energy reports: Half hour, hour, daily, monthly Annual  Energy Balance abilities to detect inefficiency Cost Calculation & monitoring  Per utility cost calculation  TOU and flat rates  Monthly and yearly reports  Single and multiple facilities Data Presentation  Tables  Interactive Charts and graphs  Export to Excel Web-based - Energy Management System

22 eXpertPower TM - Billing Tenant Management  Manage relevant date span per tenant  Automatic distribution of costs if tenant replaced Additional costs  Include additional costs in invoice  Distribute common costs such as air conditioning among tenants according to various algorithms Web-based - Energy Management System

23 eXpertPower TM - Billing Cost Calculation & monitoring  High resolution Energy calculation enables precise billing  Per utility cost calculation  TOU and flat rates  Monthly and yearly reports  Single and multiple facilities  Compare to Utility bill calculator Invoice management  Produce Invoice in PDF format  Invoice reports generator  Compare total invoices to utility bill  Allow tenant to view invoice Web-based - Energy Management System

24 eXpertPower TM - Billing  Reports pertain to consumption (kWh) and financials ($)  Dates and Time Span are configurable  TOU and Total Energy Costs  Management of expiration dates per tenant  Changing tenants in midst of billing period will result with separate bills for old tenant and new tenant  Robust capabilities for merging areas Web-based - Energy Management System

25 eXpertPower TM - Pro Web-based - Energy Management System Listing and display of various Power Quality events including:  Power Frequency  Voltage Variation, Rapid Voltage changes  Flicker severity  Voltage Unbalance,  Harmonic Voltage, Voltage dips  Undervoltage, Overvoltage, Voltage interruptions Event Summary  Number of events in requested date range  Worst case  Sequence of events  Breakdown of event types

26 eXpertPower TM - Pro Web-based - Energy Management System Waveform display and analysis  Stacked or overlapped display  Zoom in – Zoom out capabilities  Spectrum Table  Spectrum Bar  RMS Plot  Delta Tool EN50160 Standard Support  Statistics as per EN50160 standard  Category overview  Weekly compliance report  Annual Compliance report  Harmonics report

27 Thank You


Download ppt "BFM136 Branch Feeder Monitor April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality."