1 HydroLynx Systems, Inc. 950 Riverside Pkwy., #10 West Sacramento, CA 95605 916-374-1800 hydro@hydrolynx.com www.hydrolynx.com

2 Real Time Data Telemetry Systems HydroLynx Systems, Inc. manufactures, installs, and maintains Real Time Data Telemetry Systems. These systems provide our customers accurate and timely hydrological data. Our customers use this data to make decisions that protect lives and property in their communities.

3 World Wide Installations We install, service and support systems through out the world. Including exotic locations such as… The Panama Canal

4 Our Partners HydroLynx Systems, Inc. teams with other companies to provide installation and maintenance of systems. Distinctive AFWS Designs, Inc. Pacific REMS Water & Earth Technologies, Inc.

5 Onsite Training Training is provided during installation to teach our customers how to maintain and add onto their system.

6 5096 Data Transmitter The 5096 Real-Time Data Transmitter collects, processes, and transmits analog and digital sensor data on events and timed intervals. Programmable parameters control the collection, processing, and transmission of sensor data. On board 24 Kbytes data logging can store up to 4,000 event data points or more than 12,000 timed data points. Plug and Play parameter setup based on EPROM.

7 5096 Data Transmitter

8 50386 Data Collection Unit The 50386 Data Collection Unit can be configured as a transmitter, receiver, or repeater with ALERT one- way or SCADA two-way radios. ALERT, ScadaLynx, and MODBUS protocol support. Collects, analyzes, controls, and transmits analog, digital, serial, SDI-12, and virtual sensor data on events and timed intervals. On board 3 Mbytes of data logging. Configuration is programmable using the Microsoft Windows based ScadaLynx Toolbox software.

9 50386 Data Collection Unit

10 5400 Satellite Transmitter Application Remote sites with no land-based radio coverage Sensors Rainfall and water level Telemetry Commercial Satellite As close to real-time as possible Low power consumption, 12v battery Economical, keep cost down Deployment Standard HydroLynx Packaged Station

11 5400 Satellite Transmitter

12 Automated Control Systems 50386 DCU at an upstream water level site monitors water level: Pressure Transducer Float switch When alarm water levels are detected, transmit secure alarm reports. 50386 DCU at a downstream site receives alarm reports transmitted by the upstream water level site and triggers the control: Flashing roadway signs Siren

13 Flashing Roadway Sign Upstream water level triggers flashing roadway signs when water flows over roadway.

14 Automated Siren Warning Upstream high water level triggers a downstream siren.

15 Base Station Software The NovaStar base station software collects data from multiple watersheds, displays text and graphical reports, and checks for alarms. Web page data access of current and historical text and graphical data. Alarm warnings with digitized voice dialers, email, and pager notification. Siren and low water crossing light status viewing and control from web page. Automated data export in text, SHEF, and XML.

16 NovaStar 5 Software

17 Multi-user web page access to base station database No client access software required User preferences kept on client workstations Client side user interface keeps band width low SQL database design allow open access to database SQL replication used to synchronize master database with backup database servers Linux operation system Reliable and robust operating system Operating system not subject to Microsoft virus attacks Can be installed on virtual servers NovaStar 5 Software Advantages

18 Web page user interface to list and edit

19 Locally hosted database Data is kept onsite to insure ownership Local access to data continues when external internet access goes down Local database backups Multiple database servers with synchronized database A change in the master database is immediately copied to backup databases through SQL replication Scheduled database backups Intranet database backup to local backup servers Internet database backup to HydroLynx NovaStar 5 Database Advantages

20 Master Server Backup Server Remote Server Database Data collection Work Statio n Work Statio n Work Statio n

21 NovaStar 5 Data Collection Advantages All NovaStar servers collect ALERT1 and ALERT2 data Satellite and other agency (COE,USGS) imported from internet Use serial or network connections to decoders A network connection allows a NovaStar server to connect to decoders at remote locations Data received from all decoders will be blended before filing in the NovaStar 5 master database In failover mode, data is filed in the local database

22 NovaStar 5 Data Collection Advantages ALERT2 Decoder ALERT1 Decoder ALERT2 Decoder ALERT1 Decoder Network connection Serial connection Master Server Backup Server Remote Server Internet Data Collection ALERT2 Decoder ALERT1 Decoder ALERT2 Decoder ALERT1 Decoder ALERT2 Decoder ALERT1 Decoder

23 NovaStar 5 Data Processing Data validation and calibration Incremental precipitation and rating computation Check alarm conditions and notify Trigger equation computation Determine threat level Automate river forecasting Finished data exported to other agencies (NWS) Data edit

24 Data Validation and Calibration

25 Assign Ratings

26 Alarm triggers Upper limit Lower limit Rise over time (rainfall) Fall over time Distinct level No report Too many reports Data collection down Network synchronization down.

27 NovaStar 5 Alarm Checking

28 Data edit

29 Run forecast model manually or schedule automatic forecasting

30 Create plot show observed and forecast data

31 Database reads and writes can be done from any database server Web page browsers connect to one of the NovaStar 5 database servers to read and write data User login determines role for database access Users have unique login names or share a global name Login names are assigned to one or more user roles A guest role prevents write access to the database User groups limit access to the database Stations, sensors, maps, plots, and reports can be limited to a user group or user name NovaStar 5 User Access Advantages

32 Client side user interface Web page browser user interface requires no training User preferences are kept on user workstation Browser shortcuts provide quick access to pages NovaScore feature of database flags significant data Alarm triggers set data report score values Score values highlight data on maps and in data tables Links on data provide drill down functionality Edit data reports Check point parameters Recalibrate data NovaStar 5 User Interface Advantages

33 Highlight data background to show increased hydrologic threat

34 Stack time series data plots

35 Overlay time series data plots show trends

36 Plot observed and forecast rainfall

37 Custom graphic panels show area features and data readouts

38 Custom Charts show critical levels

39 Display multiple sensors at sites

40 Stack time series on charts

41 Create custom reports

42 Data can be shared by NovaStar 5 web page Scheduled reports can prepare data for public access Reports can be text, xml, html, graphic maps, plots. Reports can be pushed to another server Reports can be pulled from another server Public web page hosting Customized web page hosting with Apache server Limit public access to prevent denial of service attacks Pull data from NovaStar 5 database for public page display or Google maps Create control pages for roadway signs. NovaStar 5 Data Sharing Advantages

43 Public map highlights critical data with colored background

44 Google maps can zoom into area of interest

45 Click on data readout to show time series plot

46 Create panels to control remote warning sites

47 Your possibilities are endless HydroLynx Systems thanks you for the opportunity to make this presentation. Contact HydroLynx Systems for more information 916-374-1800 kblair@hydrolynx.com www.hydrolynx.com