IC-1600 INTELLIGENT CONTROLLER S1S2 Data + Data - Data + Data - Enable + Enable - J9 Power Supply J18 120VAC 60hz Ground Battery - Battery + (24VDC) J5.

Similar presentations


Presentation on theme: "IC-1600 INTELLIGENT CONTROLLER S1S2 Data + Data - Data + Data - Enable + Enable - J9 Power Supply J18 120VAC 60hz Ground Battery - Battery + (24VDC) J5."— Presentation transcript:

1 IC-1600 INTELLIGENT CONTROLLER S1S2 Data + Data - Data + Data - Enable + Enable - J9 Power Supply J18 120VAC 60hz Ground Battery - Battery + (24VDC) J5 Transmit ReceiveGround J1 READER INTERFACE (RI-130) Max distance2 miles CardReader Max distance 500 Enable + Enable - Figure 3.1 General System Configuration Overview Channels J5J6 J12 Input Power J15 J13 Output Points Inputs

2 Lower board J5 J6 S1 S2 J13J14 J12 J15 Upper board 5VDC 15VDC Ground Led Data1 Data0 Input 1 Exit Push-Button Input 0 Door open Detect off Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Go Output 0 Common Go Output 0 Normally Open Go Output 0 Normally Closed Shunt Output 1 Common Shunt Output 1 Normally Open Shunt Output 1 Normally Closed Output 2 Common Output 2 Normally Open Output 2 Normally Closed Data + Data - Enable + Enable - Not Used 12vac/12VDC+ 12vac/12VDC- Ground Not Used J5 goes to a channel on an IC-1600 or CE-1600 J12 connects to the card reader J6 is the input power to the RI-130 Input 2 Tamper Detect S2 configures the RI-130 System code for Degraded Mode S1 configures the RI-130s Go and Shunt time for Degraded Mode Figure 3.2 Common ( J14)

3 Door Open Detect Common To Door Contact Report Only if Held Beyond Shunt TimeReport As Forced Entry Detect (FED) -Shunt Relay Energizes -Door may stay open until Shunt Time expires -If the door is still open after the shunt time, the Door Held Open is reported under Monitor When the Door is opened, without Access Granted or an Unlock Command When Access is Granted. Door opens, then Door closes before Go Relay Times out. When Access is Granted. Door opens, then Door closes before Shunt Relay Times out. Access is Granted. Door opens, then Door closes after Shunt Relay Times out. In AG Forced Entry is reported as Door opens under Monitor Activity In AG Forced Closed is reported as Door Closes under Monitor Activity Nothing is reported in AG. Both relays reset as door closes. Nothing is reported in AG. Shunt Relay resets as door closes In AG Door Held Open is reported under Monitor Activity In AG Door closed is reported after the door closes under Monitor Activity Nothing is reported in AG. Shunt Relay resets as door closes. In AG Door Held Open is reported under Monitor Activity In AG Door closed is reported after the door closes under Monitor Activity Unauthorized Door Open Reporting in Card Reader definition Nothing is reported in AG. Both relays reset as door closes Door Sequences The Door Open Detect Monitor Point Figure 5.1 J13J14 J12 J15

4 Report Only if Held Beyond Shunt TimeReport As Forced Entry Detect (FED) Will not function Door is opened, without Access Granted or an Unlock Command Access is Granted. Door opens, then Door closes before Go Relay Times out. Access is Granted. Door opens, then Door closes before Shunt Relay Times out. Access is Granted. Door opens, then Door closes after Shunt Relay Times out. In AGForced Entry is reported as Door opens under Monitor Activity In AG Forced Closed is reported as Door Closes under Monitor Activity Nothing is reported AG. Both relays stay energized for the whole duration or the relays respected times. Nothing is reported AG. Shunt Relay stays energized for the whole duration of the shunt time. In AG Door Held Open is reported under Monitor Activity In AG Door closed is reported after the door closes under Monitor Activity Nothing is reported AG. Shunt Relay stays energized for the whole duration of the shunt time. Will Not Function Unauthorized Door Open Reporting in Card Reader definition Nothing is reported in AG. Both relays stay energized for the whole duration or the relays respected times. Door Sequences The Door Open Detect Monitor Point Figure 5.2 J13J14 J12 J15 To Door Contact Shunt Common & Normally open Door Open Detect


Download ppt "IC-1600 INTELLIGENT CONTROLLER S1S2 Data + Data - Data + Data - Enable + Enable - J9 Power Supply J18 120VAC 60hz Ground Battery - Battery + (24VDC) J5."