1 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data for Handshake Tester HT-180

2 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Current Status Built on the technology of our 882 HDCP compliance test feature – the worlds first and only commercially available HDCP Compliance Test application. Built on the technology of our 882 HDCP compliance test feature – the worlds first and only commercially available HDCP Compliance Test application. Enhanced localization features anticipated -- LCD display with error code reporting -- Save Trace Files Enhanced localization features anticipated -- LCD display with error code reporting -- Save Trace Files Provides both up-steam and down-stream views of HDMI component interactions. Provides both up-steam and down-stream views of HDMI component interactions. Troubleshoots HDCP, HPD and EDID interoperability problems and helps identify problems. Troubleshoots HDCP, HPD and EDID interoperability problems and helps identify problems.

3 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – What does it do? Assists in the troubleshooting of HDMI Interoperability and handshake problems Assists in the troubleshooting of HDMI Interoperability and handshake problems Localizes HDCP handshake problems Identifies EDID problems Identifies 5V, Current and Hot Plug Issues

4 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Typical root causes Hot Plug Failures -Checks hot plug for < 100ms deassertion -Verifies that hot plug downstream assertion is passed to upstream -Checks if hot plug detection assertion upstream was not the result of downstream problem -Measures +5v signals for voltage and current draw on a source Hot Plug Failures -Checks hot plug for < 100ms deassertion -Verifies that hot plug downstream assertion is passed to upstream -Checks if hot plug detection assertion upstream was not the result of downstream problem -Measures +5v signals for voltage and current draw on a source EDID Failures -Checks if EDID port was not acknowledged -Checks if EDID port access was attempted by source -Verifies that EDID header and checksums are valid -Checks if EDID read was triggered by hot plug detection EDID Failures -Checks if EDID port was not acknowledged -Checks if EDID port access was attempted by source -Verifies that EDID header and checksums are valid -Checks if EDID read was triggered by hot plug detection HDCP Failures -Checks for invalid Aksv from source -Verifies that source write of An occurs prior to write of Aksv -Verifies that source read of Bcaps occurs prior to read of R0 -Verifies that source write of Aksv occurs prior to read of R0 -Checks for invalid Bksv from sink -Checks if Ri is read without second phase of authentication (in case of repeater) -Checks if HDCP reauthentication was triggered by hot plug detection -Checks if HDCP port is not acknowledged -Checks for excessive HDCP re-authentication attempts by source -Verifies that source attempted to access sink HDCP port -Checks if the READY bit is not set as a result of any of the following failure conditions: Repeater did not attempt to read Bksv downstream receiver Source did not begin reauthentication after five seconds Invalid Bksv HDCP Failures -Checks for invalid Aksv from source -Verifies that source write of An occurs prior to write of Aksv -Verifies that source read of Bcaps occurs prior to read of R0 -Verifies that source write of Aksv occurs prior to read of R0 -Checks for invalid Bksv from sink -Checks if Ri is read without second phase of authentication (in case of repeater) -Checks if HDCP reauthentication was triggered by hot plug detection -Checks if HDCP port is not acknowledged -Checks for excessive HDCP re-authentication attempts by source -Verifies that source attempted to access sink HDCP port -Checks if the READY bit is not set as a result of any of the following failure conditions: Repeater did not attempt to read Bksv downstream receiver Source did not begin reauthentication after five seconds Invalid Bksv

5 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Operation HT-180 is inserted in an HDMI system. The product will test up to Three different devices for interoperability problems by displaying Error codes on the LCD as well as in HTML trace files. HT-180 is inserted in an HDMI system. The product will test up to Three different devices for interoperability problems by displaying Error codes on the LCD as well as in HTML trace files.

6 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Operation Immediate evaluation on displayed on the LCD Immediate evaluation on displayed on the LCD Set up a trace using the trace file capture software Running on a connected PC Set up a trace using the trace file capture software Running on a connected PC

7 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Operation Captured trace files allow system information to be sent to a lab for analysis. Each trace can specifically identify the components of the system tested, date and location. Captured trace files allow system information to be sent to a lab for analysis. Each trace can specifically identify the components of the system tested, date and location. Ticket No. Customer Info System Products!!

8 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Enhanced failure indication (DDC Protocol Traces) Reason & action codes -Digests DDC protocol data -Provides root cause code -Documentation provides corrective action Reason & action codes -Digests DDC protocol data -Provides root cause code -Documentation provides corrective action DDC protocol traces -USB captures DDC data -Customer service call card with documentation associates activity with DDC trace files DDC protocol traces -USB captures DDC data -Customer service call card with documentation associates activity with DDC trace files

9 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Enhanced failure indication (reason & action codes) Error Codes are shown on the LCD, indicating more precise failure mode and referring to a list of causes as well as possible solutions. Additionally, an A, B or C rating can suggest Severity of the diagnosis. Error Codes are shown on the LCD, indicating more precise failure mode and referring to a list of causes as well as possible solutions. Additionally, an A, B or C rating can suggest Severity of the diagnosis.

10 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 – Support Consultation (if necessary) DDC trace analysis Consultation (if necessary) DDC trace analysis Documentation HT-180 Error Code Reference Guide Documentation HT-180 Error Code Reference Guide

11 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data Current Reason Code Listings NO_ERROR0x00, EDID_HEADER_BAD0x01, EDID_CHECKSUM_BAD0x02, EDID_NOT_READ0x03, EDID_READ_INCOMPLETE0x04, EDID_READ_DURING_HPD_LOW0x05, EDID_READ_NACKED_HPD_HI0x06, LARGE_EDID_WITHOUT_EDDC0x07, EDID_NOT_READ_AFTER_HPD0x08, EDID_CROSSED_256_BYTES0x09, AKSV_BAD0x10, BKSV_BAD0x11, FACSIMILE_AKSV0x12, FACSIMILE_BKSV0x13, HDCP_NOT_ATTEMPTED0x14, HDCP_READ_DURING_HPD_LOW0x15, HDCP_NACKED_HPD_HI0x16, AKSV_WRITTEN_BEFORE_AN0x17,

12 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data Current Reason Code Listings AKSV_WRITTEN_WRONG_ORDER0x18, AKSV_SENT_MULT_TIMES0x19, HDCP_WENT_BEYOND_LENGTH0x1A, KSV_FIFO_READ_INCOMPLETE0x20, KSV_FIFO_READ_NOT_5_MULT0x21, KSV_FIFO_HAD_BAD_KSV0x22, KSV_FIFO_HAD_FACSIM_BKSV0x23, KSV_FIFO_WITHOUT_BSTATUS0x24, KSV_FIFO_READ_TOO_LONG0x25, KSV_FIFO_MISSING_BKSV0x26, KSV_FIFO_WITH_NO_DEVS0x27, KSV_FIFO_WITH_NO_READY0x28, R0_READ_WITHIN_100MS0x30, R0_READ_BEFORE_BCAPS0x31, R0_READ_WITHOUT_AKSV0x32, R0_READ_BEFORE_BKSV0x33, RI_MISMATCH_CAUSE_REAUTH0x34, R0_MISMATCH_CAUSE_REAUTH0x35,

13 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data Current Reason Code Listings SOURCE_USES_SHORT_READS0x36, BCAPS_RESERVED_BITS_SET0x40, BCAPS_NOT_READY_IN_TIME0x41, NO_REAUTH_AFTER_NO_READY0x42, DS_FAIL_WITH_NO_HPD0x43, BCAPS_NOT_POLLED0x44, BCAPS_READY_CAUSE_REAUTH0x45, BSTATUS_HAD_MAX_DEVS_EX0x50, BSTATUS_HAD_MAX_CASC_EX0x51, BSTATUS_RESERVED_SET0x52, BSTATUS_NOT_HDMI_MODE0x53, BSTATUS_HDMI_NO_BCAPS0x54, BSTATUS_DEVS_0_WITH_DEV0x55, BSTATUS_DEV_CNT_0_PROB0x56, BSTATUS_MAX_STAT_NO_PASS0x57, AINFO_1_1_SET_NO_BCAPS0x60, AINFO_RESERVED_SET0x61, AINFO_AFTER_AKSV0x62,

14 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data Current Reason Code Listings V_PRIME_WITH_NO_BSTATUS0x64, V_PRIME_WITH_NO_READY0x65, DOWNSTREAM_AUTH_NOT_UP0x67, DOWNSTREAM_REAUTH_NOT_UP0x68, REAUTH_CONSTANT0x69, SOURCE_STOPS_POLLING_RI0x6A, DDC_MISSING_STOPS0x6C, DDC_MISSING_STARTS0x6D, HPD_TOO_SHORT0x70, HPD_NEVER_GOES_HIGH0x71, HPD_NOT_PASSED_THROUGH0x72, HPD_NOT_HIGH_AFTER_5_SEC0x73, NO_REAUTH_AFTER_HPD0x74, AUTH_CONTINUES_AFTER_HPD0x75, VOLTAGE_TOO_LOW0x78, VOLTAGE_TOO_HIGH0x79, CURRENT_PULL_TOO_HIGH0x7A

15 Quantum Data, Inc Big Timber Road Elgin, IL USA Phone (847) Fax (847) quantum data HT-180 Diagnosis & Study The HT-180 will provide a convenient method for identifying interoperability problems in the field and help service providers develop strategies for solving customer digital HD installation problems. The HT-180 will provide a convenient method for identifying interoperability problems in the field and help service providers develop strategies for solving customer digital HD installation problems.


Download ppt "Quantum Data, Inc. 2111 Big Timber Road Elgin, IL 60123 USA Phone (847) 888-0450 Fax (847) 888-2802 www.quantumdata.com quantum data for Handshake Tester."

Similar presentations


Ads by Google