Presentation is loading. Please wait.

Presentation is loading. Please wait.

Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!

Similar presentations


Presentation on theme: "Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!"— Presentation transcript:

1 Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic! NEXT Measurement FEXT Measurement Location of XTALK Point Recognition of Bridged Taps Location of Bridged Taps Micro Interruption Detection Location of Loose Contacts LCL Balance Measurement

2 Near End Crosstalk Measurement with ELQ 30 ELQ 30 MASTER ELQ 30 SLAVE ELQ 30 MASTER ELQ 30 SLAVE FAIL PASS The location of cross talk point can be found by the TDR of ELQ 30 To visit the TDR page click on the key ELEKTR NIKA

3 Far End Crosstalk Measurement with ELQ 30 ELQ 30 MASTER ELQ 30 SLAVE ELQ 30 MASTER ELQ 30 SLAVE FAIL PASS The location of cross talk point can be found by the TDR of ELQ 30 To visit the TDR page click on the key ELEKTR NIKA

4 Crosstalk Point Location with the TDR of ELQ 30 When the XTALK is out of limit it is very likely that the reason is split. The best tool to locate the XTALK points is ELQ 30 in TDRXTALK mode. ELQ 30 Split Resplit Typical Waveform ELEKTR NIKA

5 Recognition of Bridged Taps Impedance measurement is the best tool to recognize bridged taps because they cause strongly waving line impedance FAIL IRREGULAR Typical impedance measurement result The location of bridged tap can be found by the TDR of ELQ30 To visit the TDR page click on the key ELEKTR NIKA

6 Bridged Tap Location with the TDR of ELQ 30 When the line impedance is strongly waving it is very likely that the reason is bridged tap. The best tool to locate it the TDR of ELQ 30 Typical Waveform Distance to tap Length of tap ELEKTR NIKA

7 Micro Interruption Detection Micro interruption is a temporary line interruption due to loose contacts. ELQ 30 detects the micro interruptions using 1020 Hz test tone The location of loose contact can be found by long time TDR measurement To visit the TDR page click on the key ELEKTR NIKA

8 Loose Contact Location ELQ 30 in long time TDR mode performs a sequence of repeated measurements The obtained waveforms are different if the features of tested pair change during the test Typical Waveform ELEKTR NIKA

9 Balance (LCL ) Measurement ELQ 30 MASTER ELQ 30 SLAVE ELQ 30 MASTER ELQ 30 SLAVE PASS FAIL ELQ 30 in Master-Slave mode provides a useful tool to find unbalance causing impairment of xDSL connections. ELEKTR NIKA

10 THANK YOU FOR YOUR ATTENTION!