1 HCFC SURVEY & INVENTORY, REPUBLIC OF MOLDOVA Anatolie TARITA, OZONE Office Coordinator, Ashgabat, Turkmenistan, 24-27 MARCH 2009

2 Objectives of the HCFC Survey  To carry out a survey and inventory, including survey of all major industrial units in various sub-sector;  Identification of HCFC distributors and end-users in each sub sector;  To investigate the trend and to estimate the future imports of HCFCs (HCFC consumption post 2010);  To propose some alternative refrigeration technologies being implemented in Moldova post 2010.

3 Legislation and licensing system  The Republic of Moldova has ratified the Vienna Convention and the Montreal Protocol (1996), London & Copenhagen Amendments (2001), Montreal Amendment (2005) and the Beijing Amendment 2006).  In accordance with MOP Decision IX/8, a series of additional ODS regulations were introduced by the Government of Moldova.  Fundamental legislative document concerning implementation of the Montreal Protocol in Moldova is the Law nr. 852- XV from 14.02.2002 (with amendments & modifications 2005, 2006 7 2008).  The licensing system was adopted in 1998. In order to reflect the changing situation in the country it was reinforced in 1999 and 2004 respectively.

4 The baseline consumption of CFCs  The baseline consumption of CFCs is 73.3 ODP Tonnes.  Consumption of CFCs in 2005 was 14,4 ODP tonnes, which is below the 50% of the baseline consumption.  The phase-out efforts in parallel with the remaining ongoing projects activities (i.e. end-users incentive programme), and under the TPMP (started in October, 2007) will lead to a gradual phase-out schedule in the refrigeration sector.  The refrigeration service sector is the only remaining sector in Moldova. The majority of the CFC-12 is used in the domestic sector.

5 CFC-12 consumption by sub sectors (2005 data) Sub sector Estimated Nr. of units Estimated Nr. of units charged per year Refrigerant consumption/year, (Mt) 1 Industrial refrigeration54385.3 2 Commercial refrigeration108009002.6 3 Air conditioning (water coolers)420.4 4 Domestic refrigeration1,300.000-3.9 5 Transport refrigeration55230.3 6 MAC (cars and buses)985018901.9 Total14.4

6 According to the CP import of CFC-12 beginning with 01.01.2008 is banned.

7 Fluctuation of refrigerant costs in the Republic of Moldova (production: China & Europe) Type of refrigerant Market price US $/kg, excluding taxes September, 2004November, 2006 October, 2007 December, 2008 CFC-12 5,014.016,111,0 - China 18,1 – Europe (stock 2007) HCFC-22 4,17.17,36,3 - China 8,8 - Europe HFC-134a 8,014.017,012,1 - China 16,9 - Europe HFC - blends: R-404A; R-407C, R-410A -18.519,613,2 - China 17,6 - Europe

8 HCFC Consumption by sub sectors HCFC stock and consumption (2006), Mt Subsector Number of units Refrigerant Stock HCFC Survey 2007 HCFC StockHCFC Consmp. (2006) Industrial refrigeration24514,44614,5 14 540,0Leakage 0,25% 3 635,00 Commercial refrigeration (larger installation cold rooms and central systems) 1274,0624,2 4 200,0Leakage 0,25% 1 050,00 Small commercial (display, small cold rooms, milk tanks - Restaurants, bars, hotel, butcheries, bakeries, fish, vegetables, Ice cream) 1500022,5 22 500,0Leakage 0, 40% 9 000,00 Air conditioning (large water to water and air to water) 16044,24545,6 48 670,0Leakage 0, 40% 12 167,50 Air conditioning (unitary&split systems) 420007,551,0 51 096,0Leakage 0,20% 12 774,00 Transport refrigeration6202,53,1 3 100,0Leakage 0,35% 1 085,00 TOTAL5315272,753140,9 144 106,039 711,50

9 Import of unitary & split air-conditioners Years 199519961997199819992000200120022003200420052006 Total no of units 2 1044781 1011 0236511 6778262 0795 7786 2769 22111 366 % of none HCFC equipment 10%20% HCFC containing units 2 1044781 1011 0236511 6778262 0795 7786 2768 2999 093 Content of R-22 approx. 1, 2 kg per/un. = 51,0 mt. Leakage: approx. 0,20% = 10,2 Mt/year

10 Import of HCFC-22 (data reported by the importers – December, 2008) Licensed importers/Import of HCFC-22, kg 200320042005200620072008 1. “Eurobite” S.R.L.--998,854400 2. “Coral” S.R.L.720,8680554680285,6544,0 3. “Frigoind” S.R.L.---3384394814419,2 4. “Frio-Dins” S.R.L.50006528820010000952019788,0 5. “Ecolux” S.R.L.23901243092484352924816592,0 6. “Frigomas” S.A.1088 149600 7. “VandroService” S.R.L.---530.4 0 0 8. “ T-Iustinian” S.R.L.-6120--6120 TOTAL8950,826846,020088,820578,438573,65 1343,2

11 Prognosis of the use of HCFC in Moldova Exploitation of refrigerants and, particularly, R-22 in the Republic of Moldova depends on a number of factors of internal and external character. The main internal factors are:  The economic condition of the country;  Dynamics in demand for refrigeration/air-conditioning across various sectors of economy;  Competency level of the workforce;  Awareness of the need and benefits of improved service practice among equipment owners;  Energy costs;  Regulatory influence of the government through legislative and normative acts. The external factors are:  International standards in the field of environment protection and climate change;  World trends in evolution of refrigeration equipments;  Global market situation, etc.

12 Prognosis of the use of HCFC in Moldova As of 2006-2007 in the existing refrigeration equipment, exploiting R ‑ 22 (taking into account replacement of R-12), its distribution across the sectors is approximately the following (% out of its overall amount): - in industrial refrigeration – 10%; - in commercial refrigeration – 25%; - in larger air conditioning system – 30%; - in split and unitary systems 30%; - transportation sectors – 5%.

13 Промышленно-химико- холодильные ассоциации  Ассоциация холодильщиков Молдовы, г. Кишинэу, МД2045, ул. Студенцилор, 9, тел/факс 43-89-52, е-mail: vcartofeanu@mail.utm.md, основана в 1997 г., Президент Картофяну В.Г.vcartofeanu@mail.utm.md  Национальная холодильная ассоциация, г. Кишинэу, МД2028, ул. Академией, 1, офис 411, тел/ факс 72-76-07, 72-76-11, е-mail: aso.zu@dnt.md, основана в 1997 г., Президент Академик АН РМ Болога М.aso.zu@dnt.md  Ассоциация предприятий по производству быстрозамороженной продукции, г.Кишинэу, ул. Г. Тудор,3, тел.72-76-07, основана в 1990 г., Президент Зубатый А.Л.

14 Forecast of refrigerants exploitation in various refrigeration sectors for the post - 2010 period Sector Period, years 2010 – 20202020 – 2040 Production (industrial)R-717, R-404а R-717, R-744, mixtures of natural agents Trade (commercial) R-404а, R-407А, R-407В, R-507 R-407С, R-410А R-744, Air conditioningR-407С, R-410АR-410А Household R-600а, R-600а/R-290 R-600а, R-600а/R-290 TransportationR-404аR-744

15 Thank you for your attention