Presentation is loading. Please wait.

Presentation is loading. Please wait.

Electronics Plastics Film or Paper Medical (packaging) Chemical Painting.

Similar presentations


Presentation on theme: "Electronics Plastics Film or Paper Medical (packaging) Chemical Painting."— Presentation transcript:

1

2 Electronics Plastics Film or Paper Medical (packaging) Chemical Painting

3 JAPAN INDUSTRIAL STANDARD JIS-L 1064

4 1: Probe 2: Receiver Arm 3: High Voltage Meter 4: Mode Select switch 5:Current Meter 6: Connector for Analyzing System 7: Scale 8: Driver Arm 9: CAL Lamp 10: H.V Adjust 11: MAIN Power lamp 12: Motor Lamp 13: High Voltage charging Lamp 14: Main Power Switch 15: Motor Switch 16: High Voltage Switch

5 Receiver DC Charger Turning Table Specime n

6 RECEIVERDRIVER AMPLIFIER MOTOR TURINIG TABLE SPECIMEN OPERATION SYSTEM High Voltage DC Power Supply CONTROLER (CPU) ANALOG/DIGITAL CONVERTING RECORD EQUIPEMENT CALIBRATED DATA (FLASH MEMORY) COMMUNICATION SYSTEM USB COMUNICATION COMPUTOR ANALYZING SYSTEM V-2 STATIC HONESTMETER MODEL H-0110

7 Federal TEST METHOD STANDARD 101C - 4046 For fast decay or low resistivity (under 10E6) specimen Suitable for the material resistivity 1x10E6< *** <1x10E13

8 *PC and Printer must be prepared by customer Temperature sensor cable Grounding cable Power cable USB cable Signal cable Grounding cable Power cable

9 1: Power LED (green) 2: Power Switch 3: AC Inlet 4: Fuse box 5: Grounding Terminal 6: Signal connector to H-0110 7: USB connector 8: Connector for temperature and humidity sensor HONEST DATA ANALYZING SYSTEM-V2

10 Available PC DOS/V model with USB interface Over Intel Pentium 500MHz Memory: over 128MB HDD Drive: over 2GB space LCD monitor: we recommend over 1024×768 Operation System Windows 8 (64bit) Windows 7 (32bit) Windows Vista (32bit) 、 XP(SP2 32bit) Windows XP Professional Edition Windows XP Home Edition

11 Charging up After Charged as Saturated Voltage, it start to decay. This is the point of Half Decayed time. Decayed its charged voltage

12

13

14

15 Check the really character of ESD! Resistivity Check is not real ESD phenomena. Charge up without any physical friction. Every material can be measured. Every material have each potential characteristic charged.

16  Saturated voltage (SAT)  Slope Angle of decay curve  Half(50%) decayed time  Remained voltage  Resistivity  Material of conductivity  Humidity

17 Depends on material, Sometime decay caracteristic is not same!

18 1.28 x 10E9 ohm !! Same?!? This two sample Resistivity is Sample No_01 is low charged and fast decay Sample No_16 is high charged and slow decay Resitivity of these two Sample is Decay time is quite different!!

19 1.00x10E11 ohm 1.87x10E11 ohm 1.23x10E11 ohm 2.88x10E11 ohm 1.88x10E11 ohm Resistivity 10E11 ohm level

20 1.69x10E12 ohm 4.17x10E12 ohm 1.22x10E12 ohm 5.12x10E12 ohm Resistivity 10E11 ohm level

21 Can’t be classified by Saturated voltage.

22 Safety Protection cover While the operation door open, interlock magnet switch control the High voltage output and Motor. After January 2012, for overseas model is modified as protection cover use.