1 X-STREAM Process Gas Analyzers
Customer Presentation

2 X-STREAM Overview Packaging options Common design for all 3 variations
Measurement options Operator interface and connectivity Installation Service and maintenance Features and benefits Applications

3 NEW NEW Packaging Options Three Variations Field housing
Wall mount NEMA 4X / IP66 Stainless steel housing Type approved pressurization systems and non-incendive solution for hazardous areas NEW General purpose Rack mount Tabletop Flameproof housing Wall mount NEMA 4X / IP66 Cast aluminum housing Certified for ATEX and CSA-C/US hazardous areas NEW

4 Packaging Options - General Purpose
Rack mount Standard 19” housing Small analyzer footprint Depth: 13.6 inches (344,5 mm) Minimizes space required for cabinet installations Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety

5 Packaging Options - General Purpose
Rack mount Tabletop Tabletop accessory kit to modify rack version Mount feet on the bottom plate Remove the mounting brackets (2x 4 Philips screws) Side view

6 Packaging Options - General Purpose
X-STREAM replaces BINOS 100 Series, 755 and 880 BINOS 100 2M Depth: 19 inches (482 mm) 880 / 755 Depth: inches ( mm) BINOS 100 Depth: 16.5 inches (417 mm) BINOS 100 2M Depth: 19 inches (482 mm) 880 / 755 Depth: inches ( mm) BINOS 100 Depth: 16.5 inches (417 mm) Depth: 13.6 inches (344,5 mm)

7 Packaging Options - Field Housing
Wall mount Small analyzer footprint Width: 19.1 inches (484 mm) Height: 18.1 inches (460 mm) Depth: 8.7 inches (222 mm) Minimizes overall space required for installation Minimal leakage Hinges and square sash fasteners outside of sealed compartment Safety glass directly glued to front cover Extended ambient temperature range -20 to +50 °C (-4 to +122 °F) Tropicalization for high ambient humidity NEW

8 Packaging Options - Field Housing
Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety ATEX-approved Zone 2 non-incendive solution for non-flammable gases (type approval for CSA-C/US Div. 2 pending) Pressurization/purge systems for hazardous areas NEW

9 Packaging Options - Field Housing
ATEX pressurization/purge systems for hazardous areas ATEX-certified pressurization system for Zone 1 Similar system for Zone 2 with simplified pressurization Versions for flammable & non-flammable gases NEW

10 Packaging Options - Field Housing
CSA-C/US pressurization/purge systems for hazardous areas Upgrade with a CSA-C/US approved Z purge Type approval for CSA-C/US Div. 2 pending Versions for flammable & non-flammable gases NEW

11 Packaging Options - Flameproof Housing
Wall mount Smaller analyzer footprint Width: inches (580 mm) Height: 20.1 inches (510 mm) Depth: 11.5 inches (290 mm) Minimizes overall space required for installation NEW

12 Packaging Options - Flameproof Housing
Extended ambient temperature range -20 to +50 °C (-4 to +122 °F) Tropicalization for high ambient humidity Separation of physics and electronics with purge Case purge enables measurement of corrosive and toxic gases protecting the electronics and providing operator safety Flameproof enclosure for hazardous areas Class I, Zone 1, Group IIB + H2, T4 Type approval for ATEX Zone 1 Type approval for CSA-C/US Zone 1 NEW NEW

13 Common Design for All 3 Variations
Reduced number of internal parts Reduces customer inventory Reduces required spare parts

14 Common Design Compact card cage for wide range power supply and motherboard Card cage allows extension cards (e.g. TCD board) Easy removal of motherboard using detent springs

15 Measurement Options Non-dispersive Photometry NDIR/UV/VIS
Improved NDIR capability on X-STREAM platform New components, e.g. nitrogen monoxide Lower ranges, e.g ppm CO and ppm NH3 New benches with pyro-electric (solid-state) detectors are less sensitive to ambient temperature changes NDUV channels included Sulfur dioxide Nitrogen dioxide Dynamic ranges available – analog output can be adjusted in the field between minimum and maximum concentration Paramagnetic Oxygen Solvent resistant cells Corrosion resistant cells Intrinsically safe cells

16 Measurement Options Electrochemical Oxygen Thermal Conductivity
Long-term stability Thermal Conductivity Standard aluminum cells 3 components only in contact with sample gas Aluminum, glass and Viton Long-term stability of gas-filled reference side Corrosion and solvent resistant SS cells Completely welded Quartz coated Intrinsically safe cells

17 Measurement Options Single or dual channel capability
In series or parallel Flexible combinations of measurement principles All combinations of NDIR/UV/VIS, O2 and TCD available Sample handling options offered: Autocalibration with internal valve block or external valves via digital outputs Gas sampling pump for basic applications Barometric pressure compensation Flow sensor via internal pressure switch

18 Measurement Options Thermostatic control of physics compartment
Enables low sample gas concentrations Enables measuring sample gas with higher dew point Thermostatic control Cover removed Rack mount / tabletop

19 Operator Interface and Connectivity
Preferred language selectable during run-time English, French, German, Italian and Spanish 4 x 20 Characters alphanumeric display Easy to understand text in the chosen language Measurement information Analyzer status messages GP rack mount and tabletop with LCD only Two different displays available for field housing LCD for 0 to +50 °C (+32 to +122 °F) VFD for -20 to +50 °C (-4 to +122 °F)

20 Operator Interface and Connectivity
6 Keys to operate the menu UP/ DOWN LEFT / RIGHT keys HOME key for return to measurement / abort editing ENTER key to select menu / function

21 Operator Interface and Connectivity
Status LED’s and keys labeled by use of icons Failure (red) Status message Maintenance request / function check / out of specification (red flashing) Power (green)

22 Operator Interface and Connectivity
Communication capabilities RS 485/232 with Modbus RTU protocol Standard industrial protocol for easier connectivity Ethernet with Modbus TCP protocol NEW

23 Installation Light field housing enables easy installation
Up to 26 kg (57 lbs.) Light flameproof version enables easy installation Approximately kg ( lbs.) Line Voltage: 96 – 264 VAC, 50/60 Hz for worldwide installation

24 Installation Standard I/O:
2 optically isolated analog outputs – 4(0) to 20 mA 3 status relays Analyzer failure Maintenance request / out of specification Function check (e.g. “in calibration”) Ethernet interface or serial interface (RS 485/232) Bi-directional interface

25 Installation Optional I/O: 8 digital outputs 7 digital inputs
Concentration alarms (Pre-alarm and main alarm) Control of external calibration valves or calibration status 7 digital inputs Remote calibration control Remote valve control Remote pump control

26 Installation – General Purpose
Rack mount and tabletop rear panels Analog out, relays, serial Digital in and out Power Terminals for power and signal cables Gas inlets and outlets Analog out, serial, relays Power Digital in and out Sockets for power and signal cables

27 Installation – Field Housing
Wall mount Cable glands for power and signal cables Purge gas inlet 4 supports for wall mounting Gas inlets and outlets including purge gas outlet

28 Installation - Field Housing
Power lines on screw terminals Signal lines on terminal strips Power EMI Filter Power terminals with fuses 4 cable glands for power and signals Terminals for signals

29 Installation – Flameproof Housing
NEW Electrical connections for power and signal cables NPT adapters for conduits (CSA) Cable glands (ATEX) Gas inlets and outlets, including purge gas inlet and outlet, with flame arrestors 4 supports for wall mounting

30 Installation - Flameproof Housing
Power lines on screw terminals Signal lines on terminal strips NEW Power EMI Filter Power terminals with fuses 4 cable connections Terminals for signals

31 Service and Maintenance
All assemblies easily accessible from top or front of analyzer Physics assembly Card cage and electronic boards Easy service of field housing and flameproof versions in the field Front panels are attached and swing down for service purposes User interface is visible and usable while servicing the analyzer

32 Service and Maintenance
Easy service in the field Front door flipped down User interface is visible and operable 2 nuts to loosen on both sides

33 Service and Maintenance
Easy exchange of benches or parts in the field Replacement without need for return to factory Replacement of pyro-electric bench parts without exchange of complete cell/filter cell or chopper/filter assembly (filter on pyro-electric detector) Software update by exchanging Flash PROM in the field allows to preserve Factory settings Customer settings

34 Features and Benefits Features Benefits
Small footprint and light enclosures Requires small cabinets/analyzer shelter/wall mounting space and provides easy installation Support for multiple languages Enables operators to use analyzer in native language Field Housing and Flameproof version have NEMA 4X / IP66 housing Enables outdoor use and installation in harsh environments Field Housing and Flameproof version have tropicalization available and an extended ambient temperature range: -20 to +50 oC (-4 to +122 oF) Eliminates the need for shelters in many climates Measure up to 2 components in any measuring combination Provides flexibility in using analyzers in different applications

35 Features and Benefits Features Benefits
Improved NDIR capability and added UV capability on X-STREAM platform Increased number of applications where analyzers can be used Optional thermostatic control Enables measuring lower sample gas concentrations and at higher dew points Separation of electronics and physical benches with purge capability Enables measuring corrosive and toxic gases while protecting electronics and providing operator safety Modbus communication capability over an Ethernet or serial interface Standard industrial protocol for easier connectivity

36 Features and Benefits Features Benefits
Line voltage and terminal strips for I/O connectivity Ease of installation Sample handling options Minimizes need for external sample handling system All assemblies easily accessible from front of analyzer Easy maintenance and service Benches exchanged and software updated in field without returning analyzer to factory Global certifications Enables use in non-hazardous and hazardous areas world-wide

37 Applications Refining, petrochemical and chemical process gas
Hydrogen, ammonia and fertilizer production Metallurgical process gas, hardening and heat treatment Natural gas production and distribution Safety measurement for flammable mixtures Hydrogen cooling of gas turbines Fermentation gases in biotechnology Biogas for landfill applications Scrubber and activated carbon filter efficiency control Flue gas analysis of boilers, power plants, process furnaces and incinerators