Presentation is loading. Please wait.

Presentation is loading. Please wait.

Meso-NH model 40 users laboratories

Similar presentations


Presentation on theme: "Meso-NH model 40 users laboratories"— Presentation transcript:

1 Meso-NH model 40 users laboratories
A research model, jointly developped by Meteo-France and Laboratoire d’Aérologie (CNRS/UPS) 40 users laboratories

2 Plan General presentation of the model Meso-scale simulations.
Large-Eddy simulations Surface coupling New couplings : Electricity, Hydrology, Dispersion Climatology Diagnostics

3 Space and time scales Méso-NH

4 The different meteorological model at Météo-France
Global Climate Model (GCM) (Dx > 100 km) : ARPEGE Climat NWP at synoptic scale : ARPEGE (Dx=20-25km on France) NWP at meso-a scale : ALADIN (Dx=10km) NWP at meso-b scale : AROME (2008) (Dx=2.5km) Research model for synoptic to meso-g scale : Méso-NH (Dx=50km to 10m).

5 Why do we need a high resolution research model like Meso-NH ?
To improve parameterizations for Large Scale models : fine resolution simulations allow to resolve the main coherent patterns and inform on fine scale variability. To help the evaluation and the improvement of NWP models like AROME To better understand the physics (e.g. cloud processes), to characterize local effects To carry out impact studies and use the model as a laboratory To develop new couplings (e.g. Electricity, Hydrology …) A broad variety of developments and applications

6 Meso-NH characteristics
A broad range of resolution from synoptic scales (Dx~10km), meso-scale (Dx~1km) to Large Eddy Simulation (Dx~10m) Real cases (from ECMWF, ARPEGE, ALADIN analyses or forecasts) Ideal cases  unrealistic cases - Academic cases (validation of the dynamics) - Basic studies (Diurnal cycle …) : Cloud Resolving Model (CRM) - To reproduce an observed reality (via forcings) (intercomparison : GCSS, EUROCS …) Simulations 3D, 2D, 1D From a simple to a sophisticated physics An accurate but quite expensive dynamics A set of diagnostics (budgets, profilers, trajectories …) Parallelized and vectorized A broad range of hardware system for the research community : FUJITSU, NEC, CRAY, IBM, cluster of PC No operational objective.

7 The meso-scale simulations with Meso-NH : 1km<Dx<10km
Examples : Flashfood event Hail in orographic event Cyclone Sea breeze

8 Typical configuration for a real test study
Domaine 10-km Typical configuration for a real test study A father model at 10km resolution with the deep convection scheme, the subgrid condensation scheme, the ICE3 microphysics and the 1D turbulence scheme A son model at 2.5km resolution without deep convection scheme but with the shallow convection scheme, the ICE3 microphysics and the 1D turbulence scheme Domaine 2.5-km ~ km

9 1 severe episode (+500 mm/24 h)
As many other Western Mediterranean regions, Southern France is prone to devastating flash-floods during the fall season Number of days with daily rain > 200 mm for the period [ ] on the South-East Massif Central Alpes Pyrénées 1 severe episode (+500 mm/24 h) 2002

10 Impact of the convective system on the triggering and the localization
CTRL = With cooling associated to evaporation of precipitation NOC = Without cooling Cumulated precipitation during 4 hours Gard ‘02 CTRL = With Massif Central NOR = Without Massif Central Cooling induced by evaporation of rain and orography forcing are 2 major factors inducing quasi-stationary convective systems Nuissier et Ducrocq, 2006

11 How can dynamics modify the microphysics ?
Orographic precipitation 3D (MAP) How can dynamics modify the microphysics ? ECMWF32 km 8 km 2 km Monte Lema S Pol Ronsard 3 Doppler radars ( ) 32km : 150x150 8km : 145x145 2km : 150x150 over 51 levels (Keil et Cardinali, 2003) IOP2a (F>1) IOP8 (F<1) Lascaux et Richard, 2005

12 Mean vertical distribution of hydrometeors
Orographic precipitation 3D (MAP) Mean vertical distribution of hydrometeors IOP2a IOP8 Ice Snow Graupel Snow Hail Cloud Rain IOP2a ( Strong convection) - Deep system (unblocked unstable case, high Fr=U/Nh) Large amount of hail and graupel Main process : Riming IOP8 ( Stratiform event) - Shallow system (blocked case, low Fr) Large amount of snow Main process : Vapor deposition on snow Lascaux et Richard, 2005

13 Orographic precipitation 3D (MAP) IOP2a
Radar observations graupel Simulation (Meso-NH) Z > 60 dBz 12 km 100 km Tabary, 2002 (x) hail + graupel (o) hail ( ) rain Un exemple de comparaison entre une restitution radar de paramètres microphysiques et une simulation numérique: La simulation restitue correctement l’apparition de la grêle entre 18h et 19h et l’étagement des hydrométéores: mélange grêle/graupel, grêle, mélange pluie/grêle, et pluie. Les paramètres restitués par l’algorithme radar sont: les cristaux orientés verticalement (VC) et horizontalement (HC), la neige mouillée (WS) et sèche (DS), les mélange graupel/grêle (GH) et grêle/pluie (HR), la grêle (HL), et la pluie de différentes intensités (LR,MR,HR).

14 Simulation of cyclone : case of Dina
7800 km, Dx=36km 1944 km , Dx=12km 720 km , Dx=4km 3600 km Automatic method of Initialization : Filtering/Bogussing Barbary et al.

15 Vertical cross-sections at Dx=4km
S-N W-E K K m/s m/s Horizontal wind Barbary et al.

16 Local effects : Sea breeze
Δ = 250 m 250m of resolution 20km Temperature at Marseille, the 26th june 2001 at 15h Lemonsu et al 2005a

17 Local effects : Sea breeze
Horizontal wind field 26 June 2001, 1400 UTC VAL OBS CNRS m s-1 Puget Massif Marseilleveyre City centre z = 50 m AGL West SSB South SSB z = 400 m AGL VAL OBS City centre Puget Massif CNRS South-East DSB Marseilleveyre Lemonsu et al., 2005a

18 Comparison with transportable wind lidar (TWL)
500 400 300 200 100 50 ZS (m) Marseilleveyre 190o Puget Massif CNRS (Radar) 3 km VAL (Lidar) OBS (Radar) Etoile Massif Comparison with transportable wind lidar (TWL) 26 June 2001, 1400 UTC 6 m s-1 4 2 -2 -4 -6 2.5 TWL Model D D 2.0 C C 1.5 Altitude (km) 1.0 B B 0.5 A City center City center A VDOL VDOL 2 4 6 2 4 6 Distance (km) Distance (km) Lemonsu et al., 2005a

19 The Large Eddy Simulations with Meso-NH : Large eddys are resolved : TKEresolved >> TKE Subgrid Examples : Stable BL Convective BL Impact of the pollution on the Stratocumulus diurnal cycle

20 Universitat de les Illes Balears
AN OBSERVED LLJ DURING THE SABLES98 CAMPAIGN Objective: study the mixing processes across the maximum of the wind of an observed Low-Level Jet (LLJ) using LES x = 6 m, y = 4 m, z = 2m (0 <z<100 m) and stretched above (z = 5 m at about 400 m) 100m tower Duero river basin Night: September 1998 M.A. Jiménez Universitat de les Illes Balears

21 Universitat de les Illes Balears
Results (I): Mean profiles The maximum of the wind and the height are well captured The LLJ height coincides with the inversion height The surface temperature obtained from the LES cools down much more than the observations M.A. Jiménez Universitat de les Illes Balears

22 Water vapor variability in convective BL :
Water vapor variability in convective BL : presence of dry tongues - Couvreux et al. (2005) Lidar observations LES simulation at 12h LES Simulations 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10. 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10. 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10. 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10. g/kg g/kg rv’ qv’ P3 aircraft at 0.5zi KA aircraft S(qv)<0 . . max (pdf) _ min (pdf) LES Dx=Dy= 100m, Dz<50m, Dt=7h

23 Impact of the pollution on the stratocumulus diurnal cycle = Aerosol indirect effect
0.7g/kg rc(g/kg) Simulation LES 50m Nuage non pollué Dx=Dy= 50m, Dz=10m T=36h 0TU 6 12 18 24 30 36 LWP (g/m²) Polluted : non precipitating Pristine : precipitating Evaporation of precipitation  Cooling  Limits the stratification at cloud base and the decoupling No precipitation  No Cooling  Maximum solar warming  decoupling FIRE 1 case of EUROCS : Forcing terms : a LS subsidence + cooling (dql/dt<0) and moistening (dqt/dt>0) under the inversion to balance the subsidence During the day, the thinning is not sufficient to break up the cloud. Sandu, I., 2007

24 SURFACE COUPLING

25 The SURFEX (SURface Externalized) land surface scheme
see P.Le Moigne’s presentation

26 Atmospheric CO2 modelling : May – 27 2005 Boundary layer heterogeneity
Zi = 1600m Forest : high sensible heat flux Zi = 900m Agricultural area : low sensible heat flux Sarrat et al.(2007a)

27 Atmospheric CO2 modelling : Models Intercomparison
Winter crops Absorption of CO2 Forest Respiration Sarrat et al.(2007)

28 Simulation Brouillard lors de la campagne Paris-Fog (Tardif, 2008)
Eau liquide 1er niveau (00 TU) 9 km 2.25 km 560 m 28

29

30 Application : New couplings - Hydrology - Electricity - Pollutant dispersion

31 HYDROLOGY : Development of the coupling Meso-NH-ISBA-TOPMODEL
CNRM/GMME/MICADO Crues des 5-9 septembre 2005 Débits simulés à St Martin d’Ardèche (~ 2500km2) TOPMODEL (Beven and Kirkby, 1979) distributed hydrologic model with one model by basin : 9 basins ( km²) Objectives : - Flow and rapide flood forecasts - Retroaction of the hydrology on the atmosphere - Available for AROME

32 Lightning parameterization
Explicite electrical scheme in Meso-NH Local separation of charges + - Transfert and transport of charges Microphysical and dynamical processes Electric field no E > Etrig yes Lightning parameterization Bidirectional leader (determinist) Vertical extension of the lightning Channel steps (probabiliste) Horizontal extension of the lightning Charge neutralization Barthe et al. [2005]

33 Life cycle of electrical charges in a convective cell
Simulation Méso-NH Apparition of graupel Electrization of the cloud Apparition of electric field lightning Triggering of convection Barthe et Pinty, JGR

34 Industrial accidental release : AZF
30km, Dx=500m 10%=97mg/m3 Max_obs=60mg/m3 Couche résiduelle : flux de S Couche de mélange : flux de SE Max=10% de concentration initiale 30km, Dx=500m The heaviest particles have settled : strong dry deposition on Blagnac

35 PERLE (Programme d’Evaluation des Rejets Locaux d’Effluents)
Modelling system for environmental emergency PERLE (Programme d’Evaluation des Rejets Locaux d’Effluents) Meso-NH 2 grids (Regional Dx=8km, L=240km/ Local Dx=2km, L=60km) 36 levels until 16km ALADIN initialization and coupling Meso-scale meteorology SPRAY Lagrangian particle model At least particles released Advection+Turbulence+random Applied to the 2 Meso-NH grids Dispersion

36 Climatologie . Régionalisation climatique

37 Wind climatology over the North Alps
Measurements Méso-NH 95 dates Roses Aladin 3 ans Wind climatology over the North Alps

38 OBS HYERES MESO-NH 80% ALADIN 76%

39 CYPRIM : Régionalisation climatique des pluies intenses avec le modèle Meso-NH . A.-L. Beaulant
Simulations ARPEGE Climat / OPAMED 8 (climat présent climat futur ) ARPEGE Climat / OPAMED8 : modèle couplé océan-atmosphère, rés. horizontale : ~50 km méthode d’identification des cas extrêmes pour sélectionner des situations représentatives Climat présent : 51 cas Climat futur : 52 cas Le modèle utilisé est le modèle arpege climat couplé à un modèle « océanique » opamed de résolution horizontale 10 km et les simulations suivent le scénario climatique A2 du GIEC. Ces sorties du modèle climatique vont servir de base aux simulations réalisées avec un modèle à haute résolution non-hydrostatique, le modèle Méso-nh. CL 1 CL 4 CL 1 CL 4 Sélection des cas les plus proches distance de corrélation spatiale Climat présent : 10 cas Climat futur : 10 cas CL 1 CL 4 CL 1 CL 4

40 Simulations avec Meso-nh
Configuration en 2 domaines emboités (2-way grid-nesting) Domaine 1 de résolution horizontale ~ 10 km Domaine 2 de résolution horizontale ~ 2.5 km (centré sur l’évènement convectif) Domaine 1 : Rh ~ 10 km La convection est paramétrée pour le domaine à 10 km (paramétrisation de Kain et Fritsch) tandis qu’elle est résolue explicitement pour le domaine à 2.5 km. Rh ~ 50 km ARPEGE Climat / OPAMED8 Domaine 2 : Rh ~ 2.5 km Le modèle méso-nh est utilisé ici dans une configuration de 2 modèles emboités. Le premier modèle a une résolution identique à celle du modèle climatique arpege climat d’environ 10 km et le second modèle utilise une maille plus fine de 2.5 km environ. Le modèle est utilisé en 2way grid-nesting i.e …. Les conditions initiales et les conditions aux limites sont fournies par les sorties du modèle de climat. Le domaine utilisé couvre les régions du sud de l afrance touchées par les phénomènes de pluies intenses comme les cévennes ou le roussillon. Les conditions initiales et aux limites sont fournies par les champs du modèle ARPEGE Climat / OPAMED8 (toutes les 6 heures) Les simulations débutent à 12 UTC le jour J-1 et se terminent à 06 UTC le jour suivant J+1 (42 h) ~ km MESO-NH

41 Cumuls de pluies sur les 24 1ères heures pour les 10 cas du climat futur
t0 à t UTC J-1 à 12 UTC J 431 mm 185 mm 260 mm 298 mm 460 mm 378 mm 16 mm 137 mm 291 mm 291 mm mm

42 Diagnostics

43 Amélioration des enclumes (cirrus) sur le seuil d’auto-conversion
Chaboureau and Pinty (2005) : Use of radiative transfer RTTOV to MSG Dx=30 km Amélioration des enclumes (cirrus) sur le seuil d’auto-conversion

44 Simulation de réflectivités radar
Réflectivités observées Réflectivités simulées avec Méso-NH (radar de Bollène le 8 sep à 21 UTC, élévation=1,2°) « Développement communautaire d’un opérateur-simulateur d’observation radar » (Caumont O., V. Ducrocq, G. Delrieu, M. Gosset, J. Parent du Châtelet, J.-P. Pinty, H. Andrieu, Y. Lemaître et G. Scialom, 2006 : A radar simulator for high-resolution nonhydrostatic models. J. Atmos. Oceanic Technol.)


Download ppt "Meso-NH model 40 users laboratories"

Similar presentations


Ads by Google