Presentation is loading. Please wait.

Presentation is loading. Please wait.

ispark 'i' Explosionprotection made by PTB:

Similar presentations


Presentation on theme: "ispark 'i' Explosionprotection made by PTB:"— Presentation transcript:

1 ispark 'i' Explosionprotection made by PTB:
a method for computer aided assessment and design of intrinsically safe circuits with Lo and Co - Ik_000.PPT Physikalisch-Technische Bundesanstalt Braunschweig und Berlin

2 ispark 'i' User target group
Operators of sites requiring explosion protection Manufacturers of explosion protected apparatus Third party experts Testing and certification bodies ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 104

3 ispark 'i' What does the method provide?
On the base of preset electrical source data, intrinsic safety of the source itself is checked and maximum permissible capacitances Co and inductances Lo are determined, specialities of cable reactances are picked up, granting some more headspace for site installations ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 100

4 ispark 'i' How does it work?
Systematic investigation of experimental ignition testing results, using the standardized spark test apparatus, yielded characteristic electrical and calorical parameters. A computer program uses these parameters for a model based calculation ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 110

5 ispark 'i' Competing methods
practical use of the standardized spark test apparatus analytical evaluation against reference ignition data according to IEC ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 114

6 'i' Disadvantages of practically using the standardized spark test apparatus the standardized spark test apparatus itself, including appropriate infrastructure, is required usage is prone to errors and often lengthy experimental results are dependable only if statistically analysed, the standardized type test reveals no real significance ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 119

7 ispark 'i' Drawbacks using reference ignition data
reference ignition data are available only for some very simple sources and circuits certain effects are not comprised by those data, for example non linearities and cables usage is prone to error and often lengthy reference ignition data often reveal quantita-tive contradictions ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 121

8 ispark 'i' Advantages using ispark
arbitrary electrical sources can be assessed circuits comprising both, inductances AND capacitances as well as cables, are included the application is simpliest to use reproducibility and coherence are very high ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 140

9 ispark 'i' What kind of data must be preset?
zone 0,1 resp. zone 2 (safety factor 1,5 resp. 1,0) gasgroup type of circuit including quantities for multiple sources parallel and/or serial con-nection type of freewheeling if any Cable data: L‘, C‘ and R‘ ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 150

10 ispark 'i' What kind of data are reported? summary of preset data
if the source is determined intrinsically safe, a list of maximum Lo/Co pairs which are per-missible concurrently within the circuit if inclusion of cables is claimed, additionally to Co/Lo pairs, a maximum cable length extra allowed ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 160

11 ispark 'i' What's needed to use ispark?
personnel for type in electrical data and handle the reported results a common standard PC running at least Win2000 (upto Win7_64) the program package ispark itself a license granted by PTB (royalty is € , halved for acknowledged certification bodies) Note: License includes all subsequent impro-vements/versions of ispark without additional charge ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 180

12 'i' ispark‘s status today?
in PTB using ispark is the first choice when assessing circuits for certification about one-third of European Notified Bodies have a license for ispark as well as one-third of IECEx participants weaknesses of standardized experimental type testing nowadays are found more and more - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 180

13 ispark 'i' For further information please contact
Martin Krämer, Dipl.-Ing., Ag 3.62 Physikalisch-Technische Bundesanstalt Bundesallee 100 38116 Braunschweig, DEUTSCHLAND tel: (+49) 0531/ fax: (+49) 0531/ ispark - Physikalisch-Technische Bundesanstalt Braunschweig und Berlin 190


Download ppt "ispark 'i' Explosionprotection made by PTB:"