Mechanical heart valves and Anticoagulation

Similar presentations


Presentation on theme: "Mechanical heart valves and Anticoagulation"— Presentation transcript:

1 Mechanical heart valves and Anticoagulation
Dr. Alkesh ZALA Basic Physician trainee, Dept. of Cardiology, John Hunter hospital. Introduction of heart valve replacement surgery nearly five decades ago revolutionized the treatment of valvular heart disease. Progress in the design and structure of mechanical prostheses has led to a considerable improvement in their hemodynamic features and durability.

2 Today’s discussion: Case review
The currently Available and most commonly Used mechanical prostheses. What determines the Choice of valves? Risk of Valve Thrombosis WITHOUT Anticoagulation What are the INR Targets for these valves? Are the New Generation Valves Really LESS THORMBOGENIC?

3

4 CASE 75 year old lady with subdural bleed
On warfarin for st. Jude’s bileaflet AVR alond with Bentall procedure in 2003 2007 – Embolic vertebrobassilar embolic stroke – Valve blammed THOUGH INR 3.2 Aspirin added and INR target now INR within target range on presentation Surgical drainage on presentation day 4 Heparin infusion on day 5 & Warfarin recommenced on regular dose on day 7 – TOO EARLY? A Bentall procedure involves composite graft replacement of the aortic valve, aortic root and ascending aorta, with re-implantation of the coronary arteries into the graft. 2007 – Embolic vertebrobassilar embolic stroke – Valve blammed – however no thrombus on ECHO but some fibrin deposition in the LV outflow tract

5 Day 9 – increasingly confused with headache.
Repeat CT – Acute subdural with midline shift Urgent surgical drainage Repeat CT on day13 – subdural stable. No focal Neurological deficit Heparin started Cardiology involved with regards to anticoagulation advise Summary: Elderly lady with st. Jude’s bileaflet valve along with Bentall’s procedure. Prior probable embolic stroke related to the Mechanical valve Risk of valve thrombosis Vs Serious risk of intracranial bleeding

6 - Go OFF anticoagulation for 1-2 weeks. - Warfarin restarted next week
Weighing the risk of valve thormbosis and serious significant risk of recurrence of the intracranial bleed: - Go OFF anticoagulation for 1-2 weeks. - Warfarin restarted next week Uneventful recovery without any further complications. “Gamble - Turns Out To Be a Winner “ Or “A rational evidence based decision”

7 “An ideal Prosthetic valve”
Unidirectional flow Durable : 40million cycles/year Blood compatible: no thrombus, embolus Central flow: Laminar not turbulent Closing not damaging blood cells Last but not the least important – It should be quiet

8 Evolution of Prosthetic Heart Valves
The development of the original ball-and-cage valve design can be attributed to the bottle stopper in 1858 In the early 1950’s, it led to the idea of a prosthetic heart valve consisting of a cage with a mobile spherical poppet First implanted in a human in a closed procedure in September of In 1953, marked successful use of the heart and lung machine, paving the way for the 1st open heart operations

9 Early valves In the 1960s, the Starr–Edwards ball-and-cage mechanical prosthesis became the standard replacement valve for nearly a decade. The tilting disc valve became more widely used in the 1970s to overcome some of the inherent problems of the ball-and-cage model. Both of these designs, however, were plagued by hemodynamic limitations and thromboembolic complications. In the 1980s, the St. Jude Medical bileaflet prosthesis supplanted the earlier devices as the most commonly implanted prosthetic heart valve. Since then, additional bileaflet devices with numerous design modifications have been developed and continue to be used today. Significant advances were made soon after to help further development of the heart valve.

10 Types of PROSTHETIC VALVES Tissue – porcain, bovine
Significant advances were made soon after to help further development of the heart valve. Types of PROSTHETIC VALVES Tissue – porcain, bovine Mechanical – ball n cage, tilting disc, bileaflet Different types of prosthetic valves. A, Bileaflet mechanical valve (St. Jude Medical). B, Monoleaflet mechanical valve (Medtronic-Hall). C, Caged ball valve (Starr-Edwards,). D, Stented porcine bioprosthesis (Medtronic Mosaic). E, Stented pericardial bioprosthesis (Carpentier-Edwards Magna). F, Stentless porcine bioprosthesis (Medtronic Freestyle). G, Transcatheter bioprosthesis expanded over a balloon (Edwards SAPIEN). H, Self-expandable percutaneous bioprosthesis (CoreValve,)edtronic).

11 Bileaflet valves Two semicircular leaflets that rotate about struts attached to the valve housing Good hemodynamic performance - improved flow characteristics, lower transvalvular pressure gradients, less blood flow turbulence, improved hemodynamics at a given annular diameter, a larger orifice area and low bulk and flat profile the least thrombogenic of the artificial valves most commonly implanted mechanical valves

12 FDA-approved prosthetic heart valves

13 Haemodynamics of blood flow
Profile and hemodynamics of each main valve type. A. Whereas ball and cage valves are associated with a lack of central blood ejection fraction, tilting disc valves are associated with turbulent blood flow at the lesser orifice. B. Bileaflet valves have the lowest profile compared with ball and cage valves and tilting disc valves – better transvalvular gradient. However prone to backflow

14 However, inspite of improved design and haemodynamics – still haunted by numerous complications and the most dreaded one of valve thrombosis

15 Why not always use a Bioprosthetic valve !!
Developed primarily to overcome the risk of thromboembolism that is inherent in all mechanical prosthetic valves Major problem – DURABILITY. Cuspal tears, degeneration, fibrin deposition, perforation, fibrosis, and calcification. Rate of tissue failure – by 10 years 30% and upto 60% by 15 years.

16

17 Choice of Valves Major task is to weigh the advantage of durability and the disadvantages of the risks of thromboembolism and anticoagulant treatment inherent with mechanical valves The next step is to choose a prosthesis model that provides superior hemodynamic performance to prevent prosthesis-patient mismatch (PPM) and thereby minimize postoperative trans-prosthetic gradients.

18 Criteria for selection of an aortic valve in patients undergoing aortic valve replacement (AVR) ACC/AHA guideline Class I - There is evidence and/or general agreement for the choice of a mechanical or bio-prosthetic valve in patients undergoing AVR in the following settings •  A mechanical valve in patients who already have a mechanical valve in the mitral or tricuspid position. •  A bioprosthetic valve in patients who will not take or are incapable of taking warfarin or have a major contraindication to warfarin therapy. Class IIa - The weight of evidence or opinion is in favor of the choice of a mechanical or bioprosthetic valve in patients undergoing AVR in the following settings •  A bioprosthesis in patients ≥65 years of age who do not have risk factors for thromboembolism. •  Patient preference can be considered in patients less than 65 years of age: 1. A mechanical valve is reasonable in patients who do not have a contraindication to warfarin therapy. 2. A bioprosthetic valve may be chosen after a detailed discussion of the risks of warfarin therapy compared to the likelihood of repeat valve replacement in the future. •  A homograft when aortic valve re-replacement is performed for active prosthetic valve endocarditis. Class IIb - The weight of evidence or opinion is less well established for the choice of a mechanical or bioprosthetic valve in patients undergoing AVR in the following setting A bioprosthesis in women of child-bearing age to avoid the problems associated anticoagulation during pregnancy. Data from Bonow, RO, Carabello, BA, Chatterjee, K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. A report of the Force on Practice Guidelines (Writing committee to revise the 1998 guidelines for thAmerican College of Cardiology/American Heart Association Task e management of patients with valvular heart disease). J Am Coll Cardiol 2006; 48:e1.

19 Criteria for selection of an Mitral valve in patients undergoing Mitral valve replacement (MVR) ACC/AHA guideline Class I - There is evidence and/or general agreement for the choice of a mechanical or bioprosthetic valve in patients undergoing MVR in the following settings •  A bioprosthetic valve in patients who will not take or are incapable of taking warfarin or have a major contraindication to warfarin therapy. Class IIa - The weight of evidence or opinion is in favor of the choice of a mechanical or bioprosthetic valve in patients undergoing MVR in the following settings •  A bioprosthesis in patients ≥65 years of age who do not have risk factors for thromboembolism. Among patients < 65 years of age Mechanical valve in patients with long standing Atrial fibrillation A bioprosthetic valve may be chosen in patients in sinus rhythm who elect this for lifestyle considerations after a detailed discussion of the risks of warfarin therapy compared to the likelihood of repeat MVR in the future Data from Bonow, RO, Carabello, BA, Chatterjee, K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. A report of the Force on Practice Guidelines (Writing committee to revise the 1998 guidelines for thAmerican College of Cardiology/American Heart Association Task e management of patients with valvular heart disease). J Am Coll Cardiol 2006; 48:e1.

20 Patient tailored prosthesis
Thrombogenicity of the individual prosthesis should thus be determined on the basis of reported valve thrombosis rates for that prosthesis in relation to anticoagulation intensity and valve position. The next step is to choose a prosthesis model that provides superior hemodynamic performance to prevent prosthesis-patient mismatch (PPM) and thereby minimize postoperative transprosthetic gradients. Hence, among bioprostheses with similar durability or mechanical valves with similar thrombogenicity, one should preferably select the model that provides the largest valve effective orifice area (EOA) in relation to the patient’s annulus size

21 JHH Choice Mechanical valves represent about 5 – 10% of total valve replacement ? Reason Preferred mechanical valve – Bileaflet valve Mechanical valves – Mitral > Aortic (However, Repair preferred over Replacement) Apart from co-morbidities and Patient preference AVR- Age 60 MVR – Age 70 Courtesy: Dr. Taranpreet Singh Courtesy: Dr. Taranpreet Singh Cardiothoracic surgeon, John Hunter Hospital

22 Thrombosis with Mechanical valve
Mechanical prostheses remains burdened with the risk of thrombosis – potentially fatal Valve thrombosis is any thrombus in the absence of infection attached to or near an operated valve that occludes part of the blood flow path or that interferes with the function of the valve. Risk factors: inadequate or discontinued anticoagulant therapy previous endocarditis the prosthetic valve model used LV dysfunction, LA dilatation Hypercoagulable states

23 Prosthesis Thrombogenicity
Low: St Jude Medical, On-X, Carbomedics, Medtronic Hall; Medium: bileaflet valves with insufficient data, Bjork-Shiley; High: Lillehei-Kaster, Omniscience, Starr-Edwards. Philippe Pibarot, P. et al, Selection of the Optimal Prosthesis and Long-Term Management. Circulation. 2009; 119:

24 Rate of thrombosis In absence of anticoagulation: 8.6 per 100 patient-years. With anticoagulation: risk is reduced to 1% to 3% per year. Valve thrombosis is increased with valves in the mitral position. Highest in the Tricuspid position. ?? Rate with remote valves Ref: Hurst's the Heart, 12th Edition Ref: HURST Dr. Singh – Rate of 1 -2 % per year with regards to bi-leaflet valves with anticoagulation No data about rate in remote communities

25 ACC/AHA guideline summary: Treatment of prosthetic heart valve thrombosis
Class IIa - The weight of evidence or opinion is in favor of the usefulness of the following modalities in patients with prosthetic heart valve thrombosis •  Emergency surgery for thrombosis in a left-sided prosthetic heart valve in patients with New York Heart Association (NYHA) class III-IV symptoms. •  Emergency surgery for thrombosis in a left-sided prosthetic heart valve with a large clot burden. •  Fibrinolytic therapy for thrombosis in a right-sided prosthetic heart valve in patients with New York Heart Association (NYHA) class III-IV symptoms and/or a large clot burden. Class IIb - The weight of evidence or opinion is less well established for the usefulness of the following modalities in patients with prosthetic heart valve thrombosis •  Fibrinolytic therapy as a first-line approach for thrombosis in a left-sided prosthetic heart valve in patients with NYHA class I-II symptoms and a small clot burden. •  If surgery is either high risk or not available: 1. Fibrinolytic therapy as a first-line approach for thrombosis in a left-sided prosthetic heart valve in patients with NYHA class III-IV symptoms and a small clot burden. 2. Fibrinolytic therapy in patients with an obstructed, thrombosed left-sided prosthetic heart valve, class II-IV symptoms and, a large clot burden. •  Unfractionated heparin as an alternative to fibrinolytic therapy in patients with NYHA class I-II symptoms and a small clot burden. Bonow, RO, Carabello, BA, Chatterjee, K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing committee to revise the 1998 guidelines for the management of patients with valvular heart disease). J Am Coll Cardiol 2006; 48:e1.

26

27 Anticoagulation guidelines
ACC/AHA guideline summary: Antithrombotic therapy in patients with mechanical heart valves Class I - There is evidence and/or general agreement that antithrombotic therapy is indicated in patients with mechanical heart valves in the following settings: • Warfarin to achieve a goal INR of 2.0 to 3.0 after: 1. Aortic valve replacement (AVR) with bileaflet mechanical or Medtronic Hall valves if no risk factors* are present. • Warfarin to achieve a goal INR of 2.5 to 3.5 after: 1. AVR with bileaflet mechanical or Medtronic Hall valves if risk factors* are present. 2. AVR with Starr-Edwards or disc valves other than Medtronic Hall if no risk factors* are present. 3. Mitral valve replacement (MVR) with any mechanical valve. • Role of aspirin: 1. After AVR or MVR in patients who cannot take warfarin, at a dose of 75 to 325 mg/day. 2. At a dose of 75 to 100 mg/day in addition to warfarin in all patients with mechanical valves and in patients with biological valves who have risk factors*. Class IIa - The weight of evidence or opinion is in favor of the usefulness of antithrombotic therapy in patients with mechanical heart valves in the following setting: • In the first three months after AVR, warfarin to achieve a goal INR of 2.5 to 3.5. Class IIb - The weight of evidence or opinion is less well established for the usefulness of antithrombotic therapy in patients with mechanical heart valves in the following setting: • In high-risk patients in whom aspirin cannot be used, clopidogrel (75 mg/day) or warfarin to attain a goal INR of 3.5 to 4.5. Bonow RO, Carabello BA, Chatterjee K, et al Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Circulation 2008; 118:e523.

28 European College of Cardiology guideline
General principles Thromboembolic risk is related to two factors: Thrombogenicity of the mechanical valve Low - Medtronic Hall, St Jude Medical (without Silzone), CarboMedics AVR Medium - Bileaflet valves with insufficient data, Bjork-Shiley High - Lillehei Kaster, Omniscience, Starr Edwards Presence or absence of risk factors: atrial fibrillation, left atrial dimension >50 mm, mitral valve gradient, left ventricular ejection fraction <35 percent, spontaneous echo contrast, mitral, tricuspid, or pulmonary valve replacement, or a hypercoagulable state. Recommendations for anticoagulation Until the INR is stable, intravenous unfractionated heparin (to achieve an activated partial thromboplastin time of 1.5 to 2.0) is probably safer than subcutaneous unfractionated heparin or low molecular weight heparin which, is used, should be accompanied by anti-factor XA monitoring, particularly in patients with renal failure or obesity. •  For low thrombogenicity valves, warfarin (or other vitamin K antagonist) to achieve a goal INR of 2.5 if no risk factors and 3.0 if risk factors. •  For medium thrombogenicity valves, warfarin (or other vitamin K antagonist) to achieve a goal INR of 3.0 if no risk factors and 3.5 if risk factors. •  For high thrombogenicity valves, warfarin (or other vitamin K antagonist) to achieve a goal INR of 3.5 if no risk factors and 4.0 if risk factors. Addition of antiplatelet therapy •  Relative indications Concurrent arterial disease Coronary artery stenting Recurrent embolism, but only after treatment of risk factors and optimization of anticoagulation fail to abolish the problem 4. With caged ball valves, with dipyridamole being preferred to aspirin •  Relative contraindications History of gastrointestinal bleeding, particularly associated with ulcer disease or angiodysplasia. Hyperresponders to aspirin, with excessively prolonged bleeding time. Poorly controlled hypertension, because of the risk of intracerebral hemorrhage. Elderly patients, particularly women over age 75. Patients who take multiple medications, require frequent courses of antibiotics, or have erratic INR control. The addition of antiplatelet therapy is recommended by the ACC/AHA guidelines for all patients with mechanical valves, in contrast to the ESC guidelines that only advocate it in selected patients. Butchart, EG, Gohlke-Barwolf, C, Antunes, MJ, et al. Recommendations for the management of patients after heart valve surgery. Eur Heart J 2005; 26:2463.

29 The AREVA trial compared moderate anticoagulation (INR 2. 0–3
The AREVA trial compared moderate anticoagulation (INR 2.0–3.0) to the usual regimen of INR 3.0–4.5. A similar risk in thromboembolic events was found in both arms, whereas the bleeding risk was higher in the high intensity group after a single-valve replacement with a mechanical prosthesis, either Omnicarbon or St Jude. Patients included were between 18 and 75 years old, in sinus rhythm, and with a left atrial diameter ≤50 mm on the time-motion echocardiogram. 380 patients were randomized for INR: 188 for INR 2.0 to 3.0 and 192 for INR 3.0 to 4.5. Mean follow-up was 2.2 years. Thromboembolic events, as assessed from clinical data and CT brain scans, occurred in 10 patients in the 2.0 to 3.0 INR group and 9 patients in the 3.0 to 4.5 INR group (P=.78). Hemorrhagic events occurred in 34 patients in the 2.0 to 3.0 INR group and 56 patients in the 3.0 to 4.5 INR group (P<.01), with 13 and 19 major hemorrhagic events, respectively (P=.29). Acar J, Iung B, Boissel JP et al. AREVA. Multicenter randomized trial comparison of low-dose versus standard-dose anticoagulation in patients with mechanical prosthetic heart valves . Circulation 1996; 94:

30 Data were collected on all patients with mechanical heart valves who have been seen at four regional Dutch anticoagulation clinics since The primary outcome events were episodes of thromboembolism or major bleeding (is, cerebral infarction, peripheral embolism, valve thrombosis, intracranial and spinal bleeding, and major extracranial bleeding). PATIENT: 60% had AVR, 76% had tilting disc, 19% bileaflet, and 3% ball and cage. A total of 1608 patients were followed during 6475 patient-years. Cerebral embolism occurred in 43 patients (0.68 per 100 patient-years) and peripheral embolism in 2 (0.03 per 100 patient-years). Intracranial and spinal bleeding occurred in 36 patients (0.57 per 100 patient-years) and major extracranial bleeding in 128 (2.1 per 100 patient-years). The optimal intensity of anticoagulation, at which the incidence of both complications was lowest, was achieved when the INR was between 2.5 and 4.9. International Normalized Ratio (INR)–specific incidence of all adverse events in patients with mechanical valves (all episodes of thromboembolism, all major bleeding episodes, and unclassified stroke) according to INR (A). The dotted lines represent the 95% confidence interval and according to INR, age, and position of valve (B). Incidence of thromboembolic events according to INR and patient age (upper graph) or prosthesis position (lower graph). S.C. Cannegieter, F.R. Rosendaal, A.R. Wintzen, F.J.M. van der Meer, J.P. Vandenbroucke, and E. Briet N Engl J Med 1995; 333:11-17July 6, 1995

31 LOWERING-IT trial established that the proposed LOW-INR target is safe and feasible in low-risk patients after bileaflet aortic mechanical valve replacement. prospective open-label, single-center, randomized controlled trial: age 20 to 60 years, a single-valve replacement with a bileaflet valve in the aortic position Low risk 396 patients: 197 in low INR ( ) AND 199 in standard INR group (2.0 – 3.0). Results - similar thrombotic events and a significant reduction of bleeding occurrence in the low INR group prospective open-label, single-center, randomized controlled trial : Low risk 396 patients age range 20 to 60 years, a single-valve replacement with a bileaflet mechanical prosthesis in the aortic position, with normal LV ejection fraction and LA diameter. 197 randamised to low INR group (( ; LOW-INR group) and 199 to standard INR group (2.0 – 3.0). One versus three thromboembolic events occurred in the LOW-INR and CONVENTIONAL-INR, respectively, meeting the noninferiority criterion (P = .62). Total hemorrhagic events occurred in 6 patients in the LOW-INR group and in 16 patients in the CONVENTIONAL-INR group (P = .04). It results in similar thrombotic events and in a significant reduction of bleeding occurrence when compared to the conventional anticoagulation regimen. ========== Torella, M. Torella, D. LOWERing the INtensity of oral anticoaGulant Therapy in patients with bileaflet mechanical aortic valve replacement: Results from the “LOWERING-IT” Trial. American heart Journal – Volume 160, Issue 1 (July 2010)

32

33 Are new generation valves really less thrombogenic?
All Mechanical valves models are vulnerable to thrombus formation due to high shear stress, stagnation, and flow separation. The quest to find a less thormbogenic valve was one of the prime driving force in the development of the newer heart valves Less thrombogenic materials and an improved valve and hinge design has reduced the propensity for thrombus formation and the need for aggressive anticoagulation.

34 A meta-analysis of 46 trial - a higher risk of embolic complications in patients with a caged-ball valve. The incidence of total thromboembolism was 30% lower for patients with a tilting disk valve, and 50% lower for patients with a bileaflet valve. In a meta-analysis of 46 observational studies on thromboembolic complications in patients with mechanical heart valves, we found a higher risk of embolic complications in patients with a caged-ball valve. Compared to patients with a caged ball valve, the incidence of total thromboembolism was 30% lower for patients with a tilting disk valve (RR 0.7 (95% CI 0.5–0.9)), and 50% lower for patients with a bileaflet valve (RR 0.5 (95% CI 0.4–0.7)). Cannegieter SC, Rosendaal FR, Torn M. Oral anticoagulant treatment in patients with mechanical heart valves: how to reduce the risk of thromboembolic and bleeding complications. Journal of Internal Medicine,Volume 245, Issue 4, pages 369–374, April 1999

35 In the cohort study of 1608 patients with mechanical heart valves: a clearly higher risk of thromboembolism in patients with caged-ball valves. An incidence of 0.5 per 100 patient-years was found for the bileaflet valves, of 0.7 per 100 patient-years for the tilting disk valves, and of 2.5 per 100 patient-years for the caged-ball valves In the cohort study of 1608 patients with mechanical heart valves, we also found a clearly higher risk of thromboembolism in patients with caged-ball valves, which was independent of other factors such as age or position of the valve. An incidence of 0.5 per 100 patient-years was found for the bileaflet valves, of 0.7 per 100 patient-years for the tilting disk valves, and of 2.5 per 100 patient-years for the caged-ball valves . Optimal Oral Anticoagulant Therapy in Patients with Mechanical Heart Valves: A total of 1608 patients were followed during 6475 patient-years. Cerebral embolism occurred in 43 patients (0.68 per 100 patient-years) and peripheral embolism in 2 (0.03 per 100 patient-years). Intracranial and spinal bleeding occurred in 36 patients (0.57 per 100 patient-years) and major extracranial bleeding in 128 (2.1 per 100 patient-years). The optimal intensity of anticoagulation, at which the incidence of both complications was lowest, was achieved when the INR was between 2.5 and 4.9. The overall risk of thromboembolism was also influenced by the position of the valve. The incidence was 0.5 per 100 patient-years among patients with an aortic valve, 0.9 per 100 patient-years among patients with a mitral valve, and 1.2 per 100 patient-years among those with both an aortic and a mitral valve. Cannegieter SC, Rosendaal FR, Wintzen AR, Van Der Meer Fjm, Vandenbroucke JP, Briët E. Optimal oral anticoagulant therapy in patients with mechanical heart valves. N Engl J Med 1995; 333:

36 Guideline Which valves are less thormobogenic and safe to be managed with lower INR targets?? Based on the lower reported valve thrombosis rates, both the European Society of Cardiology (ESC) and American College of Cardiology/American Heart Association (ACC/AHA) guidelines recommend a lower target international normalized ratio (INR) for current bileaflet and the Medtronic Hall monoleaflet prostheses in the aortic position than for other monoleaflet and caged-ball valves.

37 The quest continues… “Eight Commandments”: Embolism Prevention
Durability Ease and Security of Attachment Preservation of Surrounding Tissue Function Reduction of Turbulance Reduction of Blood Trauma Reduction of Noise Use of Materials Compatible with Blood Blood clotting is still a problem with mechanical valves and manufacturers continue to improve designs, sometimes using super-computing modeling tools, as well as surgical procedures. The shape of the orifice is being improved to reduce pressure losses, turbulence and shear stresses. Flow area is maximized by using stronger materials, which minimizes wall thickness. Tapering the sides of the valve pumps blood more efficiently. Researchers are looking at making heart valves out of plastic material that are flexible enough to simulate the opening and closing action. This approach may not require anticoagulation drugs. Others are working on developing artificial heart valves made from a patient's own cells.

38 References Acar J, Iung B, Boissel JP et al. AREVA. Multicenter randomized trial comparison of low-dose versus standard-dose anticoagulation in patients with mechanical prosthetic heart valves . Circulation 1996; 94: Bonow, RO, Carabello, BA, Chatterjee, K, et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing committee to revise the 1998 guidelines for the management of patients with valvular heart disease). J Am Coll Cardiol 2006; 48:e1. Braunwald's Heart Disease - A Textbook of Cardiovascular Medicine, 9th ed. Cannegieter SC, Rosendaal FR, Wintzen AR, Van Der Meer Fjm, Vandenbroucke JP, Briët E. Optimal oral anticoagulant therapy in patients with mechanical heart valves. N Engl J Med 1995; 333: Hurst's the Heart, 12th Edition Torella, M. Torella, D. LOWERing the INtensity of oral anticoaGulant Therapy in patients with bileaflet mechanical aortic valve replacement: Results from the “LOWERING-IT” Trial. American heart Journal – Volume 160, Issue 1 (July 2010) Uptodate

39 Questions?