Presentation is loading. Please wait.

Presentation is loading. Please wait.

Yulan Li, Tsinghua Uni. TILC08, 3-6 March, 2008, Sendai, Japan Performance Study of TU-TPC Prototype Using Cosmic-ray  Tsinghua University TPC group 

Similar presentations


Presentation on theme: "Yulan Li, Tsinghua Uni. TILC08, 3-6 March, 2008, Sendai, Japan Performance Study of TU-TPC Prototype Using Cosmic-ray  Tsinghua University TPC group "— Presentation transcript:

1 Yulan Li, Tsinghua Uni. TILC08, 3-6 March, 2008, Sendai, Japan Performance Study of TU-TPC Prototype Using Cosmic-ray  Tsinghua University TPC group  CDC group: » KEK » Saga University Yulan Li Tsinghua University

2 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Scheme of TU-TPC prototype Readout detector: triple-GEM, CERN standard GEM foils, 10 cm  10cm; Drift length: 50 cm

3 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan High voltage distribution R_GEM Drift strip: fPCB, width, 2 mm, Pitch, 5 mm R_GEM: variable, to match the surface potential of the top GEM foil

4 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan The prototype: photograph

5 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Prototype: readout pad Readout pad: size, 9.5 mm  1.5 mm (Pitch: 10 mm  1.6 mm), staggered 10 x 62 pads placed, only 10 x 32 pads read out due to the limitation of electronic channel number.

6 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Whole system DAQ of MDC for BESIII, IHEP, Beijing

7 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan TU-TPC Studies @ KEK Cryo center, KEK Nov.29 - Dec.25, 2007 B=1T Analysis package: DoubleFit Test conditions: Gas V GEM (V) E drift (V/cm) Garfield Simulation Value V drift (cm/  s)C d (  m/  cm) P10370134.65.5129 P10370122.15.4122 Ar:Iso:CF 4 =94:3:3265145.25.480.3 Ar:Iso:CF 4 =94:3:3260123.54.781.8 Some modification: 1.cosmic-ray trigger system: Large crystal: 50 cm  15 cm PMT: fine mesh, R5924 2.R_GEM moved outside of chamber

8 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan TU-TPC Studies @ KEK (Cont.)

9 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan TU-TPC Studies @ KEK (Cont.)

10 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Pad Response Pad Response : the average fraction of charge falling on a given pad, as function of the distance between the track and the pad center for different z regions Middle 6 rows are used in the following analysis

11 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Transverse Diffusion Constant C D Pad response @ z=0

12 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan C D -Comparison MP-TPC@KEK ★ ★ TU-TPC Gas: Ar:Iso:CF 4 =94:3:3, B=1T Ref: http://www-hep.phys.saga-u.ac.jp/ILC-TPC

13 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan x resolution – P10 Gas  PRF = 0.227 mm N eff = 26.8  PRF = 0.147 mm N eff = 34.2

14 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan x resolution – Ar:Iso:CF 4 =94:3:3 Gas  PRF = 0.147 mm N eff = 38.5(36)  PRF = 0.207 mm N eff = 23.2

15 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Pad response ~ Hodoscope Pad response @ z drift =0Diffusion in GEM detector What happens if the above two values are different? Theoretical: In analysis: If diffusion is too small, the hodoscope effect will be more obvious. We need defocus the electron in readout detector.

16 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Pad response ~ Hodoscope (cont.)  PRF = 0.227 mm N eff = 26.8  PRF = 0.147 mm N eff = 34.2 Hodoscope effect more obvious

17 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Pad response ~ Hodoscope (cont.)  PRF = 0.147 mm N eff = 38.5(36)  PRF = 0.207 mm N eff = 23.2 Hodoscope effect more obvious

18 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan N eff -Comparison TU-TPC result (B=1T) MP-TPC result (B=1T, Ar:Iso:CF 4 =94:3:3) Ref: http://www-hep.phys.saga-u.ac.jp/ILC-TPC

19 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Conclusion & Discussion TU-TPC studies @ KEK (B = 1T) shows:  Resolution can be as good as 100  m @ Z ≈ 100 mm  Measurement points fit the analytical formula very well The analytical formula was confirmed again Hodoscope effect ~ Pad response Help us to understand MPGD-TPC more deeply  For C D : For P10, a little larger than the simulation values For Ar:Iso:CF 4, quite larger than simulation, same as MP@KEK test  For N eff : More study are need ? N eff ~ V GEM, we are expecting larger N eff for larger V GEM

20 Yulan Li, Tsinghua Uni., TILC08, 3-6 March, 2008, Sendai, Japan Future Plan  The prototype is setting up again in Tsinghua  More studies will be given in a quieter condition  But without magnetic field