Presentation is loading. Please wait.

Presentation is loading. Please wait.

Mile stone 1 Project report Anh Phan Nguyen

Similar presentations


Presentation on theme: "Mile stone 1 Project report Anh Phan Nguyen"— Presentation transcript:

1 Mile stone 1 Project report Anh Phan Nguyen apn15@pitt.edu

2 Introduction – Home temperature context An idea from ubiquitous computing: collect data from sensors to make inference about user current context. Then to make decision that make user feel comfortable. Using temperature sensor and current out-door temperature we may know if the temperature context of a house is comfortable or not. Some third parties may be interested in this context and are eager to help.

3 Home temperature context Current timeOut door temperatureRoom temperatureInterested party SummerVery hotHotFan/air conditioner vendors. Any time-Extremely hotFire department. WinterVery coldColdDepartment manager. Heating device vendors. Health department.

4 System overview Outdoor temperature SIS Home context monitor Uploader Home context website Temperature sensor Input Processor Apartment manager Advertisement companies Fire department Health department

5 Scenarios Overtime, raw data from sensor is send to InputProcessor component. MsgID = 30 Input processor component extract temperature data, send Temperature Reading message to SIS. MsgID = 101. SIS relays to HomeContextMonitor component. Overtime, OutdoorTemperature component extract outdoor temperature data in the areas where client lives, feed to the HomeContextMonitor. MsgID = 102. HomeContextMonitor based on room temperature and outdoor temperature, send alert message to SIS if the values excess some thresholds. MsdID = 38. (table in slide #3). SIS relays the message to uploader. Uploader receive message ID = 38, upload to the website. The website displays the content based on who is the client. For example, only fire department can see the alert that room temperature is too hot, while the vendors and department manager can see data if the temperate is in the “not so comfortable” threshold.

6 Message types - component messages Temperature sensor data 30Sensor Data InputSensorTypeTemperatureTemp21.69DateTime2014-10-24 10:49:31 Temperature reading 101TemperatureReadTemp21.69DateTime2014-10-24 10:49:31 Weather reading 102Outdoor temperatureTemperature42DateTime HomeContext alert message 38Emergency AlertAlert TypeGeneral AlertRoomTemp35OutdoorTemp32SubTypeVSDateTime Subtype of HomeContext alert message can be F, H, VS, VW for fire department, health department, vendor_summer and vendor winter.


Download ppt "Mile stone 1 Project report Anh Phan Nguyen"

Similar presentations


Ads by Google