10/3/2003Andreas Jansson - Tevatron IPM review1 Tevatron IPM Motivation and overview.

Similar presentations


Presentation on theme: "10/3/2003Andreas Jansson - Tevatron IPM review1 Tevatron IPM Motivation and overview."— Presentation transcript:

1 10/3/2003Andreas Jansson - Tevatron IPM review1 Tevatron IPM Motivation and overview

2 10/3/2003Andreas Jansson - Tevatron IPM review2 Why an IPM in Tevatron? Emittance preservation –Directly detect injection matching and emittance blowup. –Continuous emittance evolution e.g. on ramp (complement to FW, fills the low energy gap in SL).

3 10/3/2003Andreas Jansson - Tevatron IPM review3 An IPM example from RR Beam size Profile Position Raw data

4 10/3/2003Andreas Jansson - Tevatron IPM review4 Wish-list At injection: Measure beam size turn-by- turn to 10% accuracy (N turn >> 100). On front porch, during ramp and at flat top: Measure average beam size to 3% accuracy or better (follows from first bullet). Measure pbars with protons in machine (but not necessarily measure both particle types simultaneously).

5 10/3/2003Andreas Jansson - Tevatron IPM review5 Some beam parameters… Intensity: –Protons: 3.5 10 10 - 3.5 10 11 (nominal 2.7 10 11 ). –Pbars: 1 10 10 - 1 10 11 (nominal 2.7 10 10 ). Beam size –Injection: ~1.7 mm –Flat top: ~0.5 mm Bunch separation 396ns (no 132ns operation assumed)

6 10/3/2003Andreas Jansson - Tevatron IPM review6 People MCP test stand A. Bross, PPD QIE board designK. Bowie, PPD CD liaisonM. Bowden, CD Timing fanoutT. Fitzpatrick, PPD Project oversight etcA. Jansson, BD Simulations and PPD liaisonH. Nguyen, PPD Front end cabling etcC. Rivetta, BD Mechanical designL. Valerio, BD Instrumentation liaison etcJ. Zagel, BD Buffer/Combiner board design R. Kwarciany, CD SoftwareD. Slimmer, CD + others

7 10/3/2003Andreas Jansson - Tevatron IPM review7 Test stands QIE test setup (FCC) –Noise and cabling tests RF test setup (Footprint) –Parasitic RF coupling –Impedance MCP tests setup (Village)* –Gain uniformity etc * operational soon

8 10/3/2003Andreas Jansson - Tevatron IPM review8 Today’s Agenda Introduction and charge (Pushpa), 5 minutes Motivation for Tev IPM (Andreas) 10 minutes Existing IPMs, performance and known issues (Jim) 10 minutes Generation, transport, multiplication and detection of the ionization electrons (Andreas) 20 minutes The effect of primary statistics and noise (Hogan) 15 minutes Overview of proposed system (Andreas) 20 minutes QIE ADC board (Kwame) 10 minutes BTev data buffer board (Mark) 10 minutes Cost and manpower estimate (Andreas) 10 minutes General introduction Basic considerations Proposed implementation The $$$