Presentation is loading. Please wait.

Presentation is loading. Please wait.

Status of the BaBar Simulation Geant4 Workshop 30 September 2002 Dennis Wright.

Similar presentations


Presentation on theme: "Status of the BaBar Simulation Geant4 Workshop 30 September 2002 Dennis Wright."— Presentation transcript:

1 Status of the BaBar Simulation Geant4 Workshop 30 September 2002 Dennis Wright

2 Outline BaBar Overview Comparison projects –EM process validation –Hadronic process validation Performance

3 The BaBar Detector

4 Overview of the BaBar Simulation Objectivity Database Event Generator Tracking, Physics, Hit Scoring ( Bogus, GEANT4 ) Detector Response And Background Mixing (SimApp) Reconstruction And Analysis (Bear)

5 Use of Geant4 in BaBar BaBar uses: –Geometry –Hit-scoring –Decay processes –EM physics processes (< 10 GeV) –Low energy hadronic processes (< 10 GeV) BaBar does not use: –Standard tracking/navigation –Detector response –Persistence

6 BaBar/Geant4 Validation (1) 1 million events generated by October 2000 –B0B0bar, Bhabha, dimuons Use to test gross features of simulation: –Material model validation –Tracking/resolution tests –G3/G4/Data comparison of EM processes –Rough check of hadronic processes –Tests of performance/robustness

7 BaBar/Geant4 Validation (2) Detailed comparisons of MC and data –11 million event sample completed July 2002 > 25 different event types simulated –Goals: fine tuning of EM processes (check recent improvements) Take a serious look at hadronic processes Examine calorimetry, tracking, PID

8 EM processes/calorimetry

9

10

11 Tracking

12

13 Hadronic Validation Currently using low energy parameterized model –Not especially appropriate for BaBar energies (50 MeV – 10 GeV) –Several fixes reported by LCD group at SLAC – passed to G4 –Some included in toolkit, some to be included soon Use latest MC data set and BaBar “thin target” tests to search for and fix other problems Very recent results from tests –hadronic group hasn’t seen them yet

14 BaBar “Thin Target” Hadronic Tests

15

16

17 Hadronic Validation Hadron kinetic model (40 MeV – 10 GeV) will be perfect for BaBar –Will switch to that as soon as it is ready SLAC (T. Koi, D. Wright) has recently joined in the hadron kinetic model validation effort First effort – develop validation test bench for p,n, pi, K –Compare data, kinetic model at 500 MeV – few GeV

18 Performance (1) Simulation stage of generic B0-B0bar event includes event generator, tracking, hit-scoring –On 866 MHz PIII takes 5.0 s/evt –Used Geant4 4.0 Currently running MC production at 19 sites (1 billion events so far) Run failures due to Geant4 getting rare –< 1 per million events –A few annoyances remain

19 Performance (2) BaBar recently decided to double the MC/data ratio (to 3) Speed issues now more important than ever Geant4 part of BaBar simulation time 30-40% Options: –Simplify detector geometry –Use parameterized showers –Use faster machines (new 1.4 GHz machines being tested)

20 Conclusions EM validation well in hand –A little tweaking remains Hadronic validation beginning in earnest –Results will be passed to hadronics group Huge amount of MC data to be produced using Geant4 over life of experiment –Seeking ways to speed up simulation


Download ppt "Status of the BaBar Simulation Geant4 Workshop 30 September 2002 Dennis Wright."

Similar presentations


Ads by Google