1 ICORR Technologies, Inc.
2016 NACE SIEO - Sun Valley January 7, 2016 What is Cathodic Protection?

2 Anode Systems Design and Construction
Deep Anode System Distributed Anode System Advantages and Disadvantages Design Considerations Material Selection Site Considerations Installation Practices Environmental Considerations

3 Deep Well Anode System Single or multiple vertical bore holes – 200’ to 500’ Multiple anodes spaced in bottom of bore hole Venting System Conductive backfill Anode Junction Box External Power source – (Impressed Current)

4 Deep Well Anode System

5 Distributed Anode System (Surface Bed)
Several Shallow Vertical or Horizontal Holes Individual Anodes Conductive Backfill Anode Header Cable or Anode Junction Box External Power Source or Galvanic

6 Distributed Anode System (Surface Bed)

7 Distributed Anode System (Surface Bed)

8 Distributed Anode System (Surface Bed)

9 Distributed Anode System (Surface Bed)

10 Distributed Anode System (Surface Bed)

11 Distributed Anode System (Surface Bed)

12 Advantages Of a Deep Anode System
The Anodic Potential Gradient Is Lower In the Near-Surface Soils Smaller Land Surface Area Requirement Lower Soils Resistivity Fewer Systems Required

13 Disadvantages Of a Deep Anode System
Design Information Installation Equipment Needs Cost Of Installation ??

14 Advantages Of a Distributed Anode System
Design Information Ease Of Installation Works Well In Areas Of Electrical Shielding Cost Of Installation ??

15 Disadvantages Of a Distributed Anode System
The Anodic Potential Gradient Is Higher In the Near-Surface Soils Larger Land Surface Area Requirement Equipment Exposure To Damage More Systems Required (Galvanic) Limited CP Current Available (Galvanic) Polarized Potentials Difficult To Obtain

16 Design Current Required To Protect The Structure Geology & Hydrology
Surface Testing

17 Material Selection Anode Selection Backfill Wire Venting System

18 Site Considerations Availability Of AC Power Foreign Structures
Accessibility Property Owner or ROW Agreement

19 Installation Practices
Safety Drilling Operations Electrical Log Placing Anodes Pumping Or Placement Of Backfill Surface Completion Commissioning

20 Environmental Considerations
Surface Water Runoff Subsurface Aquifer Materials Contamination

21 Deep Well Cathodic System

22 Deep Well Cathodic System

23 Deep Well Cathodic System

24 Continuous Horizontal Anode

25 Continuous Horizontal Anode

26 Galvanic Anode Installation

27 Typical Wire Connection to Pipe

28 Impressed Current Anodes

29 Corrosion Pit

30 ICORR Technologies, Inc.
Questions? What is Cathodic Protection?