Presentation is loading. Please wait.

Presentation is loading. Please wait.

Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC 1 Solution for Power Supervision 001-79146 Rev *J Presentation: To provide an engineering.

Similar presentations


Presentation on theme: "Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC 1 Solution for Power Supervision 001-79146 Rev *J Presentation: To provide an engineering."— Presentation transcript:

1 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC 1 Solution for Power Supervision 001-79146 Rev *J Presentation: To provide an engineering overview to customers for a Cypress solution. Title slide: To define what the presentation will cover. The subtitle is a one-sentence statement of the key opportunity. Fail-Safe Power Supervision for Mission-Critical Systems: Simplify Your Design with a Customized, One-Chip Solution

2 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Power Supervision Must Be Fail-Safe Market Vision: To define the market opportunity. Presents compelling data and end product photos relevant to the local market. Should use compelling photographs of actual PSoC products. Ethernet switch by HP Three Power Supervision ICs per switch Rack-mounted servers Two to four Power Supervision ICs per server Fail-safe Power Supervision is a Must for Mission-Critical Systems Telecommunication switches and networking routers Rack-mounted servers and storage switches Industrial automation and medical imaging equipment Power Supervision provides critical reliability functions System power must work flawlessly all the time Power rails must be ramped up and down in proper sequence with proper delays Power rails must be monitored precisely for irregular activity Fault Detection and recovery must be fast and flawless Mission-Critical Systems require a customized, fail-safe Power Supervision solution 3

3 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Terms You Will Hear Today Terms of Art (ToAs): To clearly define tor engineers all ToAs used in the presentation. To carefully and fully define Cypress-proprietary ToAs needed to explain our system solution. Voltage Sequencing Ramp-up and ramp-down of power rail voltages in proper sequence with proper delays Power Monitoring Continuous observation of power rail voltage and current Trimming Power rail adjustments used to maintain optimal voltage ranges despite unexpected power variations Requires continuous adjustment of the power rail output voltages Fault Detection Continuous comparison of power rail voltage and current to over-threshold and under-threshold limits Power Supervision Power rail Voltage Sequencing, Power Monitoring, Trimming and Fault Detection 4a

4 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Additional Terms Terms of Art (ToAs): To clearly define tor engineers all ToAs used in the presentation. To carefully and fully define Cypress-proprietary ToAs needed to explain our system solution. Point of Failure (PoF) Any part of a system that can fail Fewer PoFs provide better system reliability Event-Based Sequencing Custom sequencing of power rails based on events (e.g., faults, status of other power rails) Implemented with user-defined state machines Fault Logging Storage of faults in non-volatile memory for debug and analysis Margining System validation and qualification with maximum and minimum voltages of the power rails Requires temporary adjustments of the output voltages of power rails Ensures the system functions properly across the entire specified voltage ranges 4b

5 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Terms of Art (ToAs): To clearly define tor engineers all ToAs used in the presentation. To carefully and fully define Cypress-proprietary ToAs needed to explain our system solution. PSoC Terms 100+ other User Modules to complete the system design Voltage Sequencer User Module for Power Supervision 4c PSoC Designer™ PSoC 1 Integrated Design Environment (IDE) Software that installs on your PC Allows concurrent hardware and firmware design of PSoC systems User Modules Free embedded ICs represented by an icon in PSoC Designer software Used to integrate multiple ICs and system interfaces into one PSoC Dragged and dropped as icons to design systems in PSoC Designer Inherently connected to the MCU via the main system bus Power Supervision User Modules integrate ICs for power rail Voltage Sequencing, Power Monitoring, Trimming and Fault Detection User Module Wizards Simple Graphical User Interfaces in PSoC Designer Embedded in each User Module Used to customize User Module parameters Launched by right-clicking a User Module MCU Inherent system bus connection Voltage Sequencer User Module continuously sequences the voltage of the power rails using the integrated ADC in PSoC Voltage Sequencer User Module Icon

6 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC solves these problems PSoC supports 20 power rails per chip, 2x other Power Supervision ICs PSoC User Module Wizards create customized Power Supervision configurations in minutes PSoC monitors voltage and current with 2.00% accuracy and performs real-time Trimming PSoC creates a one-chip, customized, fail-safe Power Supervision solution Traditional Approach and Challenges: To present the traditional approach and the challenges engineers will face when using it to realize the Market Vision. Ends with a one-sentence segue clearly stating the benefit of the Cypress solution. Design Problems Engineers Face 1. The number of power rails is increasing 16+ power rails per board often need Power Supervision Requiring up to 2 Power Supervision ICs per board More ICs = more PoFs 2. Every design requires difficult, time-consuming customization for Different number of power rails Different Voltage Sequencing, Power Monitoring, and Trimming parameters Fault Detection and Fault Logging referenced to custom thresholds 3. Monitoring voltage and current accuracy is critical to system reliability Trimming voltage accuracy is critical to maintain optimal voltage ranges Customers require solutions to provide < 3.00% accuracy 5 48-port Gigabit Ethernet Switch Each switch has more than 16 power rails

7 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM VoltageSequencer TIMER And prototyped and validated using the PSoC and Power Supervision Kits… To get started, you should: Buy $249 PSoC Kit (CY8CKIT-001)PSoC Kit Buy $129 Power Supervision Kit (CY8CKIT-035)Power Supervision Kit Install PSoC Designer software and Power Supervision Kit on your PCPSoC Designer Open the example project in the Power Supervision Kit Use the Power Supervision App Note for complete system design guidelinesPower Supervision App Note PSoC One-Chip Solution And create system designs that are customized in minutes by entering parameters into each of the User Module Wizards… Actual IBM PSoC Power Supervision Design PSoC Designer User Modules integrate common Power Supervision ICs… Voltage Sequencer Wizard PSoC Kit Power Supervision Kit Blade Server by IBM To create a one-chip, customized, fail-safe Power Supervision solution. Cypress Solution: To introduce CY products and show compellingly how they solve the challenges highlighted on the previous slide. To provide a short, clear list of what to do to get started. Voltage Sequencer User Module VoltageSequencer With added option for Fan Controller 6a

8 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM System Design in PSoC Designer IDE Cypress Solution: Compelling PSoC Designer introduction to solve the challenges highlighted on the previous slide. Provides a short, clear list of what to do to get started. 1.Explore the library of 100+ User Modules 2.Drag and drop User Module icons to complete your hardware system design in the main design workspace 3.Configure User Modules using the User Module Wizards 4.Access User Module datasheets directly from the User Module Wizards 5.Codesign your application firmware with the PSoC hardware using the PSoC Designer IDE 6.Review the PSoC Power Supervision App Note for complete system design guidelines Power Supervision Example Project in PSoC Designer IDE 6b

9 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC Voltage Sequencer User Module Create a custom, event-based Voltage Sequencer in minutes Drag and drop the Voltage Sequencer User Module into the main design workspace Right-click the User Module to customize your parameters with the User Module Wizard Choose the number of power rails to be sequenced (up to 20) and the nominal voltage of each rail Enter ramp-up delay and ramp-down delay for each power rail with 200-µs resolution Choose your fault response parameters with option for 10-µs response time Enter Event-Based Sequencing parameters, including dependencies for other power rails and system control inputs Enter the number of retries and delays for re-sequencing Use the graphical waveform display to visualize your design Voltage Sequencer User Module Voltage Sequencer User Module Wizard Cypress Solution: To give details on CY products and show compellingly how they solve the challenges highlighted on a previous slide. To provide a short, clear list of what to do to get started. Ramp-up and ramp-down of power rail voltages in proper sequence with proper delays Use the Voltage Sequencer User Module Wizard to expand the number of power rails up to 20 VoltageSequencer 6c

10 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Example Project from the Power Supervision Kit with five power rails Example Project With Five Power Rails 1.Event-Based Voltage Sequencing for sequencing one primary and four secondary power rails 2.Real-time Trimming on four secondary power rails 3.ADC-based voltage and current monitoring of all five power rails 4.Over-voltage and under-voltage Fault Detection on power rails Power Supervision Example Project: Digital Workspace Cypress Solution: To give details on CY products and show compellingly how they solve the challenges highlighted on a previous slide. To provide a short, clear list of what to do to get started. 6d Power Supervision Example Project: Analog Workspace

11 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Use the Power Supervision Kit (CY8CKIT-035) Connect to your PSoC Kit (CY8CKIT-001) Prototype with the five (one primary, four secondary) power rails provided in the kit Or attach your own power rails using on-board connectors Open the PSoC 1 Power Supervision Example Project Configure your Power Supervision parameters with User Module Wizards Watch our demo video: www.cypress.com/go/video-PSoC1PowerSupervisionwww.cypress.com/go/video-PSoC1PowerSupervision Prototype Your Solution Cypress Solution: To give details on CY products and show compellingly how they solve the challenges highlighted on a previous slide. To provide a short, clear list of what to do to get started. Power Supervision Kit (CY8CKIT-035) V1 = 5-V power rail Power Jack 12V in V2 = 3.3-V power rail V4 = 1.8-V power rail Power Supervision Kit (CY8CKIT-035) V3 = 2.5-V power rail I2C connector 6e PSoC Kit with PSoC 1 processor module (CY8CKIT-001)

12 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Solution Examples: To give detailed one-page PSoC Solution Examples from the field in the specified format. PSoC ® 1 Power Supervision Solution Example – Server Design Challenges Deliver low-cost system solution Provide flexible Power Monitoring and Voltage Sequencing Support reliable Power Supervision PSoC Solution Reduces BOM cost by 40% Reads “power good” signals and enable regulators Implements Power Monitoring and Voltage Sequencing Simplifies troubleshooting with EEPROM Fault Logging PSoC Value App Note:Power SupervisionPower Supervision Kits:PSoC Kit (CY8CKIT-001)PSoC Kit Power Supervision Kit (CY8CKIT-035)Power Supervision Kit Video:PSoC 1 Power Supervision SolutionPSoC 1 Power Supervision Solution Suggested Collateral PSoC Designer User Modules Voltage Sequencer (ramp-up and ramp-down of voltages) PWM (enables Trimming on three power rails) Power Monitor (continuous observation of voltage and current) EEPROM (Fault Logging in non-volatile memory) I 2 C (communication interface) Block Diagram PSoC 1 One-Chip Solution Power Supervision User Modules Host I2CI2C 2 M8 MCU 8 Power Monitor POLs / Regulators Blade Server by IBM With sequencing and monitoring for three power rails 3 3 POL Enables Voltage EEPROM (Emulated) Flash SRAM Power Good Voltage Sequencer 3 7 PWM 3

13 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC Solutions vs. Competition’s Feature PSoC 1 (low cost) PSoC 3 & PSoC 5LP TI UCD9081 RENESAS R5F21262SNFP No. of Rails for Sequencing 2032812 No. of Rails for Monitoring 2432812 Accuracy 2.00%0.26%6.00% 2.00% with Ext. Reference No. of Rails for Trimming 122402 EEPROM Fault & Event Log 2 KBytes None2 KBytes PoFs (16 rails) 1122 Competitive Comparison: To define key features of the Cypress solution and demonstrate its superiority over NBA(s). Must be credible and objective to the salesperson and customer. 8

14 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM Competitor Power Supervision IC: Renesas 4-Rail Sequencer and System Health Monitor R5F21262SNFP#X6 Price: $2.67 1 BOM Integration Power Supervision IC: Renesas 4-Rail Sequencer and System Health Monitor R5F21262SNFP#X6 Price: $2.67 1 $2.67 $5.34 Competitor Power Supervision IC BOM Integration Value Total Value Delivered Target PSoC Solution: Total Cost: 34% Total Savings: CY8C28445-24PVXI $3.50 1 $1.84 1 Digikey website 1ku pricing on 1/9/2015 EVC Slide: To clearly define the value of the Cypress solution, including BOM integration and unique functionality. 9 PSoC 1 Power Supervision Solution Value

15 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM 1.View our demo video: www.cypress.com/go/video-PSoC1PowerSupervision www.cypress.com/go/video-PSoC1PowerSupervision 2.Buy the PSoC Kit and Power Supervision Kit: www.cypress.com/go/CY8CKIT-001www.cypress.com/go/CY8CKIT-001 (CY8CKIT-001) $249 www.cypress.com/go/CY8CKIT-035www.cypress.com/go/CY8CKIT-035 (CY8CKIT-035) $129 3.Install PSoC Designer software: www.cypress.com/go/PSoCDesigner www.cypress.com/go/PSoCDesigner Here’s How to Get Started Storage arrays by IBM Call to Action: To tell customers how to start their design process. Basestation equipment by Fiberhome Hongxin IBM storage array has up to 64 RAID adapter boards with sequencing and monitoring for up to 12 power rails 11

16 Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM References and Links References and Links: Provide comprehensive view of resources to assist in learning about and adopting the solution Demo Video: www.cypress.com/go/video-PSoC1PowerSupervisionwww.cypress.com/go/video-PSoC1PowerSupervision Demonstration of the CY8CKIT-035 PSoC Power Supervision Kit Power Supervision Kit (CY8CKIT-035): www.cypress.com/go/CY8CKIT-035www.cypress.com/go/CY8CKIT-035 Contains kit documentation and example project for Power Supervision design PSoC Kit (CY8CKIT-001): www.cypress.com/go/CY8CKIT-001www.cypress.com/go/CY8CKIT-001 Contains processor modules for PSoC 1, PSoC 3 and PSoC 5LP, documentation and example projects User Module Datasheet for Voltage Sequencer: www.cypress.com/voltagesequencermodulewww.cypress.com/voltagesequencermodule App Note AN78646 for Power Supervision: www.cypress.com/go/AN78646www.cypress.com/go/AN78646 App Note AN78692 for Fan Controller: www.cypress.com/go/AN78692www.cypress.com/go/AN78692 Cypress Platform PSoC Product Roadmap: www.cypress.com/go/PSoCRoadmapswww.cypress.com/go/PSoCRoadmaps 13


Download ppt "Engineering PresentationOwner: SSHI Rev *JTech lead: RLRM PSoC 1 Solution for Power Supervision 001-79146 Rev *J Presentation: To provide an engineering."

Similar presentations


Ads by Google