Presentation is loading. Please wait.

Presentation is loading. Please wait.

Developed by Allan Goodger Moss Vale TAFE From Boards originally developed by Ken Postill Ultimo TAFE.

Similar presentations


Presentation on theme: "Developed by Allan Goodger Moss Vale TAFE From Boards originally developed by Ken Postill Ultimo TAFE."— Presentation transcript:

1 Developed by Allan Goodger Moss Vale TAFE From Boards originally developed by Ken Postill Ultimo TAFE

2 Ken’s Board Faults introduced by 3 x 9 Gang switches Contacts oxidise, and as a result a high resistance is introduced into the circuit Limited number of faults can be introduced into the circuit Very good at developing fault finding techniques in students in realistic scenario  Next

3 Allan’s Board Faults introduced by Separate Fault Card Plugged into a socket All circuit conductors from every circuit can be modified All conductors are cut at this set of sockets  Next

4 Board Contains Power Circuit Mixed Circuit Light Circuit Hot Water & Range Circuit  Next

5 Hot Water & Range Circuit Circuit to load is as per all other circuits Terminates with flying leads Load characteristics can be modified by the fault card  Next

6 Fault Socket B&R Enclosure PJ221507 2 x 3mm groves are routered into the box lid Socket PCB is inserted into slots from the back of the lid Clamped into position by an insulated metal plate  Next

7 Fault Socket B&R Enclosure PJ221507 Lid Vero Board Jaycar Part N o HP 9544 Socket Strips Farnell Part N o 9728856 Cardboard acting as insulation 3mm Mild steel with 3/16” threads cut into each corner 3/16” Screws Installed from the front of the lid  Next

8 Socket Pin-Outs Range Load Spare Range HWS Light Power 2 Power 1 Pins 17-19 Pin 16 Pins 13-15 Pins 10-12 Pins 7-9 Pins 4-6 Pins 1-3 From Switchboard From Loads HWS Load Range HWS Light Power 2 Power 1 Pin 16-18 Pins 13-15 Pins 10-12 Pins 7-9 Pins 4-6 Pins 1-3 Only Half of the socket is used This allows the fault card to be spun around and a second set of faults can be introduced  Next

9 Fault Card Fault card installed  Next With Fault Pin 1 Fault card N o See paperwork

10 Fault Card Fault card installed  Next Without Fault

11 Fault Card Side View  Next Back View Header pins Farnell Part N o 9729038

12 CB Enclosure Load side of CBs are easily accessible By using a 4mm 2 (yellow) crimp lug and crimping a 2.6mm Brass welding rod in it  Next

13 CB Enclosure Neutrals are easily removed By the use of turned plugs  Next Cable should be min of 50 strand for flexibility

14 Improvements Add/incorporate a handle into board  Next

15 Improvements Add/incorporate a handle into board Add spacers in-between clamping plate and back of lid The front of the lid between the screws tends to bow outward  Next

16 Improvements Add/incorporate a handle into board Add spacers in-between clamping plate and back of lid Pass the socket connecting wires through PCB before soldering Solder  Next

17 Equipment Requirements See supplied equipment list  Next

18 More Information? Moss Vale TAFE Kirkham Street Moss Vale Phone: 4868 0132 Mondays Mobile: 0418 460 220 Email: allan.goodger@det.nsw.edu.au Contact: Allan Goodger  Next


Download ppt "Developed by Allan Goodger Moss Vale TAFE From Boards originally developed by Ken Postill Ultimo TAFE."

Similar presentations


Ads by Google