Presentation is loading. Please wait.

Presentation is loading. Please wait.

Chapter 15 Lesson Goal After completing this lesson, the student shall be able to attack Class B fires and coordinate interior attacks following the policies.

Similar presentations


Presentation on theme: "Chapter 15 Lesson Goal After completing this lesson, the student shall be able to attack Class B fires and coordinate interior attacks following the policies."— Presentation transcript:

0 Essentials of Fire Fighting, 5th Edition
Chapter 15 — Fire Control Firefighter II

1 Chapter 15 Lesson Goal After completing this lesson, the student shall be able to attack Class B fires and coordinate interior attacks following the policies and procedures set forth by the authority having jurisdiction (AHJ). Firefighter II

2 Specific Objectives 1. Summarize considerations for hoseline selection. 2. Discuss stream selection. 3. Discuss suppressing Class B fires. 4. Explain why bulk transport vehicle fires are difficult incidents. (Continued) Firefighter II

3 Specific Objectives 5. Discuss control of gas utilities.
6. Discuss command at structural fires. 7. Extinguish an ignitable liquid fire. (Skill Sheet 15-II-1) (Continued) Firefighter II

4 Specific Objectives 8. Control a pressurized flammable gas container fire. (Skill Sheet 15-II-2) 9. Establish Incident Command and coordinate interior attack of a structure fire. (Skill Sheet 15-II-3) Firefighter II

5 Hoseline Selection Factors
Fire conditions Fire load, material involved Volume of water needed Stream reach needed (Continued) Firefighter II

6 Hoseline Selection Factors
Number of firefighters available to advance hoselines Need for speed, mobility Tactical requirements Ease of hoseline deployment Potential fire spread Firefighter II

7 Stream Selection Dictated by fire situation, capabilities of nozzle being used Solid-stream nozzle projects water in more-or-less solid mass (Continued) Firefighter II

8 Stream Selection Combination (fog) nozzles project water in range of patterns Straight and solid streams Combination fog nozzles Firefighter II

9 Converting Water to Steam
Critical to heat absorption Excess steam production can obscure vision, inflict steam burns Appropriate water application methods critical Firefighter II

10 Class B Fires Those that involve flammable and combustible liquids, gases Flammable liquids — Flash points less than 100ºF (38ºC) (Continued) Firefighter II

11 Class B Fires Combustible liquids — Flash points higher than 100ºF (38ºC) Divisions of flammable, combustible liquids Hydrocarbons Polar solvents Firefighter II

12 Actions and Precautions
Avoid standing in pools of fuel/runoff water because there may be fuel floating on top of water PPE soaked with flammable/combustible liquids must be removed from service until cleaned (Continued) Firefighter II

13 Actions and Precautions
Unless leak can be stopped, do not extinguish fires around relief valves/ piping Try to contain pooling liquid until flow can be stopped (Continued) Firefighter II

14 Actions and Precautions
Boiling Liquid Expanding Vapor Explosion (BLEVE) Applying foam is most often used for flammable liquid fires (Continued) Firefighter II

15 Actions and Precautions
Class B fire fighting techniques also needed for fires in gas utility facilities/highway incidents involving fuel tankers Water can be applied in several forms Firefighter II

16 Using Water to Control Class B Fires
Water alone ineffective extinguishing agent Using water as cooling agent Using water as mechanical tool Using water as crew protection Firefighter II

17 Bulk Transport Vehicle Fires
Follow preincident plans Techniques of extinguishment similar to fires in flammable fuel facilities Major differences in vehicles transporting flammable fuels, storage facilities Firefighter II

18 Traffic Guidelines Close at least one lane of traffic in addition to incident lane during initial emergency operations Avoid using road flares because of possible ignition (Continued) Firefighter II

19 Traffic Guidelines When law enforcement personnel unavailable, firefighters should be assigned to direct traffic, control scene access (Continued) Firefighter II

20 Traffic Guidelines Position fire apparatus uphill, upwind (Continued)
Firefighter II

21 Traffic Guidelines Exit apparatus, work from the side away from traffic as much as possible Turn wheels of vehicles parked to protect firefighters so apparatus cannot be pushed into them if struck by another vehicle (Continued) Firefighter II

22 Techniques Be aware of possibility of vehicle tires failing
Know status/limitations of water supply Protect trapped victims with hose streams until rescue Determine exact nature of cargos Firefighter II

23 Control of Gas Utilities
Firefighters should have working knowledge of hazards, correct procedures for handling incidents involving natural gas, liquefied petroleum gas (Continued) Firefighter II

24 Control of Gas Utilities
Natural gas or LPG used for cooking, heating, industrial processes Natural gas used as fuel for buses, motor vehicles Firefighter II

25 Natural Gas In pure form is methane; flammable, nontoxic
When delivered to customers, may contain trace amounts of ethane, propane, butane, pentane Lighter than air (Continued) Firefighter II

26 Natural Gas Nontoxic, but an asphyxiant
No odor of its own, but odor added Distributed from gas wells to point of use by pipes Explosive between 5-15 percent in air (Continued) Firefighter II

27 Natural Gas May be compressed, stored, shipped in cylinders marked as compressed natural gas (CNG) Shipped, stored as liquid (LNG) and subject to BLEVE in this form Emergencies involving natural gas Firefighter II

28 Liquefied Petroleum Gas (LPG)
Bottled gas Refers to fuel gases stored in liquid state under pressure Two main gases in this category —Butane and propane Propane (Continued) Firefighter II

29 Liquefied Petroleum Gas (LPG)
About 1.5 times as heavy as air Explosive in concentrations between 1.5 and 10% Shipped from distribution point of usage in cylinders and tanks on cargo trucks (Continued) Firefighter II

30 Liquefied Petroleum Gas (LPG)
Stored in cylinders, tanks near point of use Supply of gas may be stopped by shutting valve at tank (Continued) Firefighter II

31 Liquefied Petroleum Gas (LPG)
LPG leak will produce visible cloud of vapor that hugs ground Cloud of unburned gas may be dissipated by fog stream All LPG cylinders, tanks can BLEVE Firefighter II

32 Flammable Gas Incidents
Incidents involving both CNG, LPG distribution systems most often caused by excavation equipment striking underground pipes, causing a break Contact utility company immediately (Continued) Firefighter II

33 Flammable Gas Incidents
Approach from, stage on upwind side even if gas not ignited First concerns are evacuation of area immediately around break, evacuation of area downwind, elimination of ignition sources (Continued) Firefighter II

34 Flammable Gas Incidents
Check surrounding buildings for odor of gas because service connections near break may have been damaged Follow departmental SOPs regarding crimping off gas line to stop leak (Continued) Firefighter II

35 Flammable Gas Incidents
If gas is burning, flame should not be extinguished If necessary, use hose streams to protect exposures (Continued) Firefighter II

36 Flammable Gas Incidents
In many structure fires, an important task is locating gas meter and turning off gas supply to involved building In some industrial, institutional occupancies, critical equipment and processes depend on uninterrupted supply of natural gas (Continued) Firefighter II

37 Flammable Gas Incidents
In most homes and businesses, meter is located outside building and often visible from street If the gas meter involved in fire, firefighters assigned to turn off gas should be protected by hoseline set on wide fog pattern (Continued) Firefighter II

38 Flammable Gas Incidents
Flow of gas into building can be stopped by turning cutoff valve to closed position, which is set at right angle to pipe Firefighter II

39 Company-Level Fire Tactics
Standard tactical priorities — Life safety, incident stabilization, property conservation Order of priorities same, but actions taken on fireground may/may not be performed in that order Firefighter II

40 Command — First Due Engine Company
Company officer will conduct rapid initial assessment of situation Assessment determine further actions taken by first-due engine company (Continued) Firefighter II

41 Command — First Due Engine Company
If by taking immediate action company can save 1+ lives, will do so even if not enough firefighters on scene to form rapid intervention crew (RIC) (Continued) Firefighter II

42 Command — First Due Engine Company
If no obvious, immediate life-safety concerns, and fire threatening to extend to another nearby structure, officer may order lines pulled to apply water to exposure Officer may call for more resources (Continued) Firefighter II

43 Command — First Due Engine Company
Given a small interior fire, company officer usually assumes Command of incident Firefighter II

44 Command — Other Companies
Second-due engine company Fireground support company Rapid Intervention Crew (RIC) Chief Officer/Incident Command Firefighter II

45 Summary Attacking fires early in their development is an important aspect of a successful fire fighting operation. Likewise, selecting and applying the most effective fire attack strategy and tactics are also important. (Continued) Firefighter II

46 Summary Failing to do any of these things can result in a fire growing out of control, an increase in fire damage and loss, and possibly in firefighter injuries. (Continued) Firefighter II

47 Summary Firefighters need to know how to use the fire fighting tools and techniques adopted by their departments. Firefighter II

48 Review Questions 1. What are three factors to consider in hoseline selection? 2. When would combination fog nozzles be used? 3. What is a boiling liquid expanding vapor explosion (BLEVE)? (Continued) Firefighter II

49 Review Questions 4. What are the major differences in fires in vehicles transporting flammable liquids and fires in storage facilities? (Continued) Firefighter II

50 Review Questions 5. What questions does the company officer of the first-due engine company ask when conducting a rapid initial assessment of the situation? Firefighter II


Download ppt "Chapter 15 Lesson Goal After completing this lesson, the student shall be able to attack Class B fires and coordinate interior attacks following the policies."

Similar presentations


Ads by Google