Presentation is loading. Please wait.

Presentation is loading. Please wait.

Fill and COMSEC Procedures for the AN/PSC-5 Series Radios

Similar presentations


Presentation on theme: "Fill and COMSEC Procedures for the AN/PSC-5 Series Radios"— Presentation transcript:

1 Fill and COMSEC Procedures for the AN/PSC-5 Series Radios

2 DAMA Orderwire Important Information for COMSEC Custodian, Planner and Operator
DAMA Orderwire is an unclassified live key that is utilized around the world by every radio on a DAMA SATCOM network. The DAMA Orderwire is a weekly key. You (COMSEC Custodian) MUST check the callout for the correct segment for the week of operation prior to issuing the key. If you do not, you most likely will give out to wrong segment and the operator WILL NOT communicate and you (COMSEC Custodian) will be required to complete a COMSEC Incident report for each key wrongly handled. In addition, the Orderwire must be correct short title for the footprint they are operating in. NCTAMS SATELLITE AZIMUTH SHORT TITLE PSC-5 POS Virginia CONUS 100/105W AKAT / AKAE C5592 1 & 2 Naples, Italy LANT 15/23 AKAT / AKAE C5594 3 & 4 Guam IO 72/72.5E AKAT / AKAE C5596 Hawaii PAC 172/177E AKAT / AKAE C5598 The operator has the capability to enter two weeks of orderwire at once in the radio. So when the weekly turnover occurs, there will be no break in communications. Then when the operator has the time, the operator can write over the expired week with the next week’s OW. The only issue we have here is when operating in a 5 KHz MHOP network, the operator will be required to maintain both keys required for operation and at the time of changeover, the operator must shut down and load the next OW keys to operate. The same Orderwire is used for both 5 KHz and 25 KHz Networks. NOTE; Positions 5-8 are not used. See PSC-5 Support with DAMA document for NCTAMS POC info. Or contact PSC-5 Support for further info at

3 FILLING RADIO WITH ANCD
Refer to Handout

4 FILLING RADIO WITH ANCD
“ICOM” Select Radio from “soi radio supervisor” screen on ANCD. Select SEND Displays “ send to” select Radio Select ICOM Displays “connect to RT AUD\FILL connector” using W-4 cable connect to ANCD to radio aud/fill connector, press down arrow key one time. Displays “Set function switch to ld on rt.” Set RT to load and press the down arrow key one time. Displays do you want to include time select yes. Press Ld on Rt. ANCD displays ICOM transfer successful. *Note if RT displays BAD or ANCD displays fail handshake then check the connection of the W-4 cable… you must have o-rings on both ends, ensure pins are clean and shiny you can use an eraser to clean the pins… sometimes it takes a couple of tries to work successfully. If it stills does not work try zeroizing the RT.

5 Loading SINCGARS Loadset
PSC-5D Function Switch to F2 Select Hot Key 3 ANCD Select “Radio” Select “Send” Select “Abn” “Do you want to load COMSEC to a KY58 (Y/N)” “Do you want to load an airborne radio? (Y/N)” Connect ANCD to RT ( ) Set FCTN switch to LD on RT ( ) (Ignore) Prepare to load ESET On Radio Press ENT Once filled store in position 01 Disconnect ANCD ANCD will come up as fill failed (Ignore)

6 FILLING RADIO WITH ANCD
“TEK” Select RADIO from soi radio supervisor screen, on ANCD. Select COMSEC Select LD Select TEK Select the TEK for your mission, or ask the comsec custodian for the appropriate TEK for the time. Find it by scrolling down using the P DN key on the ANCD. Once you find the TEK, select it by pressing ENTR on the ANCD. XMT should appear on the bottom right corner of the ANCD display. Select QUIT. Displays connect ANCD to RT, press down one time. Press LD on RT. TEK transfer successful, press STO and the alpha numeric for the channel you are using for example (press STO and 6 for channel six.)

7 CT-3 Loading instructions for the AN/PSC-5D
AN/CYZ-10 CT-3 Loading instructions for the AN/PSC-5D

8 Steps for F1 AN/CYZ-10 AN/PSC-5
Power-up by pressing the “ON/OFF” button on the top right of the keyboard. Select “Xmit”. Press ENTR button. Select “A_xmt” Press” ENTR” Select “Platform” Press” ENTR” Use the “P UP” and “P DN” to search through the list for the Platform you need to load in your radio. (SOTM F1) Once found, Select “Sel_plt” and Press “ENTR” AN/PSC-5 Confirm nothing is attached to the radio. Turn the Mode switch to PT and allow BIT to complete. Turn Mode switch to CT and allow to initialize. If nothing is currently loaded in the radio it will come up with the message “Proceed to F1 and hit ENT Twice” Turn the mode switch to F1 and press ENT twice. Select “DS-101” (Used for CT-3 only) Connect the AN/CYZ-10 to the Radio “FILL” Port via a fill cable. Select Automatic and Press “ENTR” Watch the screen on the radio and it will count the fills being loaded in the radio AN/CYZ-10 will return to the Main menu when complete. Cycle power on the radio before moving on. COMSEC Randomized Proceed to F1 and Press ENT Twice (0) F1: COMSEC Connect Device 1-Transfer Variables Sel Device: DS-101

9 Steps for F2 AN/CYZ-10 AN/PSC-5
Select “Transmit” Press ENTR Select “Platform” Press ENTR Use the “P UP” and “P DN” to search through the list for the Platform you need to load in your radio. (SOTM F2) Once found, Select “Sel_plt” and Press “ENTR” AN/PSC-5 Turn the mode switch to F2. Select “DS-101” (Used for CT-3 only) Confirm the connection of the AN/CYZ-10 to the Radio “FILL” Port via a fill cable. Select “Automatic” and Press ENTR Watch the screen on the radio and it will count the fills being loaded in the radio The AN/CYZ-10 will return to the Main menu when complete. F2: TRANSEC Connect Device 1-Transfer Variables Sel Device: DS-101

10 Simple Key Loader (SKL)
AN/PYQ-10 Simple Key Loader (SKL) PSC-5 Series As the opening lesson topic of the training course, all information pertaining to the conduct and administration of the course will be covered. Explain the scope and objective of the course to the students. All training materials to be used by the student during the conduction of training will be identified and briefly discussed. An introduction to each major item of the radio will be explained to each student. Given applicable instructions on the conduct and administration of the course, each student will adhere to the guidelines and requirements established. Given applicable instructions on the introduction of each major item of the AN/PSC-5D, the student will have the knowledge to identify the components of the system.

11 SKL DS-101 Loadset Creation
Plats Tab selected File->Add Platform Enter (Name, Path, Bussed) Eqs Tab selected File->Add Equipment Enter (Name, Type, Path, Buss Addr) Platform Tab selected File->Assign->Equipment Select Equipment, Enter File->Assign->Key Tags Select Key, Next Select Location, Finish

12 SKL Receiving Keys 2 Methods Create Key Tag (TM pg 2-257)
File->Create Key Tags Must fill in Tag information File->Receive->Key Needed Pull in Key (TM pg 2-183 File->Receive->Key Must fill in Tag info if DS-102 or verify DS-101

13 SKL-RT DS-101 Load An Platform or an individual Key can be loaded by DS-101. Loading or ‘Transmit’ can be done by a ‘LOAD’ shortcut in the upper right hand corner or by highlighting the Platform or Key and selecting File->Transmit->Load

14 SKL-RT DS-101 Platform Load
Plats tab selected Highlight Platform name to load Load shortcut or File->Transmit->Load Gathering Data occurs Load ECU Wizard comes up to verify info. Connect Device, Next Any checkmark commands are to be performed on device to be loaded, Send

15 SKL-RT DS-101 Key Load Plats, Eqs or Keys tab selected
Highlight Key name to load (Navigate down to the Key symbol if in Plats or Eqs tab) Load shortcut or File->Transmit->Load Gathering Data occurs Load ECU Wizard comes up to verify info. Connect Device, Next Any checkmark commands are to be performed on device to be loaded, Send

16 SKL-RT DS-101 Hopset Load Plats or Eqs tab selected
Highlight Location name to load (Navigate down to the LOC symbol) Load shortcut or File->Transmit->Load Gathering Data occurs Load ECU Wizard comes up to verify info. Connect Device, Next Any checkmark commands are to be performed on device to be loaded, Send

17 SKL-RT DS-102 Key Load Keys tab selected
Highlight Key name to load (Navigate down to the Key symbol) Load shortcut or File->Transmit->Load Key Load Settings comes up Select settings (Default settings work) Next Connect Device, Change any info if needed, OK Press Initiate in Receiving Device

18 General Troubleshooting Filling COMSEC
Step #1: Zeroize the radio (Rotate the Mode Switch to Zero and allow "Complete" to appear on the display) Step #2 Cycle Power (Turn Mode Switch to OFF the back to PT and allow BIT to complete) Step #3: Go to the Main Menu (Once BIT Completes, Press ESC twice) Step #4: Press 6 then 4 (Takes you to Maintenance, Erase Parameters) Step #5: Press 1 for Erase Parameters (Complete this by selecting Yes and waiting for "Complete" to appear in the display) Step #6: Press 2 Restore Factory Settings (Complete this by selecting Yes and waiting for "Complete" to appear in the display) Step #7: Cycle power, stop at PT to allow the BIT to complete (Current LOS operating Mode will appear when complete, unless the radio fails BIT) Step #8: Follow the included instructions for loading COMSEC

19 3.41 RECEIVE OVER-THE-AIR REKEY (OTAR)
Perform the following steps to receive an Over-the-Air Re-key (OTAR). OTARs may be sent in VINSON, FASCINATOR, ANDVT, MELP, or KG-84 modes of operations. NOTE When in ANDVT or MELP, the AN/PSC-5D can transmit OTARs to legacy equipment (e.g. KY-99, KY-100) but cannot receive OTARs from legacy equipment. The AN/PSC-5D can receive OTARs in ANDVT or MELP from another AN/PSC-5D, an AN/PSC-5C, or an AN/ARC-231. Ensure the terminal is in CT and has the current TEK and KEK for the appropriate crypto mode of operation installed. b. Configure the radio for the appropriate operating mode. c. Wait for NCD sending station to establish communications.

20 Spike says; If you require further assistance, our helpdesk is always ready; Call CONUS OCONUS Be sure to leave a message if no one answers, they will return your call shortly. 24 Hour Cell: (260) Or “I want to thank you for using our product. I am looking forward to supporting your communications needs. Our customer’s success is my mission.” Jason E. Smith


Download ppt "Fill and COMSEC Procedures for the AN/PSC-5 Series Radios"