1 EAGLE QUANTUM PREMIER SYSTEM TRAINING July 2006
DETECTOR ELECTRONICS CORPORATION EAGLE QUANTUM PREMIER SYSTEM TRAINING July 2006

2 Welcome Agenda Introductions Systems Overview
Systems Class 102 Welcome Agenda Introductions Systems Overview

3 Agenda Day 1 EQP Overview EQP Flame Detection EQP Gas Detection
Break for Lunch EQP System Q & A Hardware Exercise

4 Agenda Day 2 S3 Software Introduction S3 Software Exercise
Break for Lunch Logic Programming Product Approval Q & A

5 Day 3 Redundancy and Development Discussion Support
Agenda Day 3 Redundancy and Development Discussion Support

6 Systems Group Overview
Definition Goals Market Structure & System Types Organization Capabilities Eagle Quantum Premier Brief Overview

7 Definition What is a Systems Project?
An Engineered solution that includes Any combination of flame and/or gas detectors or other field devices A signal receiver/controller Any combination of output signals and/or devices required by the customer A system enclosure or panel Power source/battery back-up Custom Documentation

8 Group Goals To be the world’s leading supplier of-
Conventional Fire & Gas Detection Systems Addressable Fire & Gas Detection Systems Fire Suppression & Emergency Shutdown Systems Special & Custom Systems

9 F & G Systems Market Structure
TOTAL PROJECT/EPC DEVICES MICC F & G SYSTEM Supplied by Det-Tronics Growth with greater systems offering ESD SYSTEM Growth with greater device offering EPC = Engineering Procurement & Construction Bechtel Brown & Root ABB Siemens Honeywell Dooley Tackeberry Hiller Wilson Hima, Triconex ICS, Wormald Silvertech High Hazard Component Suppliers MICC = Main Instrument Controls Contractor Det-Tronics Systems Market Growth Plan

10 Typical Plant Control Systems
Stand-alone systems Plant SIS - Fire Alarm, Flame Detection, Gas Detection & Suppression System Plant ESD - Emergency Shut Down Plant SCADA or Distributed Control System

11 Conventional System Configurations
Logic Solver/PLC/Panel by others Home-run Field Wiring

12 Addressable Fire & Gas System
Ports RS-485 serial Link (Modbus RTU) Configuration (serial port) Redundant media ControlNet MIR Fire Detection UV/IR Fire Detection IR Fire Detection Supervised Inputs Heats, Smokes and MAC’s Agent Release DCIO Module PRESS HERE TRYKK HER KNUS GLASSET BREAK GLASS BN- 300 BRANNALARM Tilpasningsenhet FIRE ALARM Interface unit Nr. No. UV Fire Detection HC Gas Detection 4-20mA input Toxic Gas Detection Premier Controller European Certifications 94/9/EC ATEX EN & 2 Electromagnetic compatibility EN Immunity of fire, intruder and social alarm systems EN Detection and measurement of gases North American Certifications FM Flame performance FM 6310/6320 Gas performance NFPA National Fire alarm code CSA - gas performance and Haz locations

13 Capabilities Project Management USA, Singapore, and UK
Project Engineering USA, Singapore Systems Staging USA (Minneapolis and Houston), Singapore Field Service USA (Minneapolis and Houston), London, France Singapore, & China plus representative organization

14 Capabilities Total Safety Solutions
Fire Detection /Mitigation systems: Fire Detection Gas Detection Fire Suppression systems CO2, Water Mist, FM200 Emergency Shutdown (ESD) Systems Safety controllers Triconex, HIMA, others Fire Alarm Systems Eagle Quantum Premier Fire alarm panels (Pegasys, KI 1019, FENWAL, Vega)

15 Capabilities System Support Power Supply systems (batteries…etc)
Human Machine Interface (HMI) systems Documentation - Non-standard/custom requirements Manufacturing Record Books, Test Plans, Support Field Service Installation Supervision FAT/SAT In-house Expertise

16 Organization Chart

17 Systems Support Singapore Minneapolis CAPABILITIES Sales Proposals
Proj. Mgmt System Integration Subcontract FAT CAPABILITIES Worldwide Coordination Sales Proposals Proj. Mgmt System Integration FAT Houston UK CAPABILITIES Sales Proposals Proj. Mgmt System Integration FAT CAPABILITIES Sales Proposals Proj. Mgmt FAT

18 System Overview and Features
Eagle Quantum Premier System Overview and Features

19 Addressable - Hazardous Location

20 Det-Tronics - Eagle Systems Evolution
Evolved to meet our customer’s needs Eagle2000™ Hazardous Event Monitoring System Introduced 1993 Eagle Quantum Introduced 1996 Eagle Quantum Premier Introduced 2003

21 EQP - Description Eagle Quantum Premier (EQP) System-
is the latest generation in the Eagle addressable system family combines “fire detection and extinguishing agent release” and “hazardous gas monitoring” in one complete package is intended for use in hazardous locations is designed to meet the requirements of global approval agencies supports up to 246 devices supports a LON length of 2000 meters with base system can be expanded using network extenders to a max LON distance of 10,000 meters

22 EQP Addressable Fire & Gas System 246 node maximum
BN- 300 BRANNALARM Tilpasningsenhet FIRE ALARM Interface unit Nr. No. PRESS HERE TRYKK HER KNUS GLASSET BREAK GLASS Supervised Inputs Heats, Smokes and MAC’s Agent Release Signal / Audible Devices SAM UV/IR Fire Detection X5200 I/O Modules Relay AIM IPM DCIO Module ARM UV Fire Detection X2200 IR Fire Detection X9800 24 vdc power supply Battery PSM Network Extender IDC HC Gas Detection Eclipse Toxic Gas Detection DCU / DCUEX Supervised Digital inputs Premier Controller Ports Configuration (serial port) RS-485 serial Link (Modbus RTU) Redundant media ControlNet MIR Fire Detection X3301 North American Certifications FM Flame performance FM 6310/6320 Gas performance NFPA National Fire alarm code CSA - gas performance and Haz locations European Certifications 94/9/EC ATEX EN & 2 Electromagnetic compatibility EN Immunity of fire, intruder and social alarm systems EN Detection and measurement of gases Operator Interface Station running S3 software Ver 2.8 OPC option

23 EQP - Controller The system consists of a “multi-channel programmable controller” and a number of addressable microprocessor based field devices. Scrolling alphanumeric display provides status information Flexible communication options Significantly smaller, yet far more powerful than Eagle Quantum system controller

24 EQP - Field Devices - Legacy
Supports Eagle Quantum “Legacy” field devices. EQ2500ARM Agent Release Module. EQ2500SAM Signal Audible module. EQ2200IDC Initiating Device Circuit module. EQ2200IDCGF Ground Fault monitor. EQ2200DCU & EQ2200DCUEX Digital Communication Units. EQ2400 Network Extender EQ2100 Power Supply Monitor

25 EQP Field Devices - Gas Detector
PIRECL Pointwatch Eclipse Combustible hydrocarbon detector Software programmable for various gases: Methane,Ethane Propane, Butane, Ethylene, Propylene Supports handheld interrogator connection in field using HART protocol.

26 EQP – Field Devices - Flame
X-Series is EQP ready UV/IR (X5200) UV (X2200) IR (X9800) Multispectrum IR (X3301)

27 Ultraviolet Flame Detector (X2200)
Improved ARC rejection algorithm 1850 –2450 Angstroms solar blind Multiple fuel verified

28 Single Frequency Infrared Flame Detector (X9800)
Time Domain Signal Analysis, IR signal processing Analyzes the raw IR sensor signal “randomness” Rejects signals that do not meet randomness criteria 4.45 micron solar blind Quick fire response Heated optic Multiple fuel verified

29 Ultraviolet Infrared Flame Detector (X5200)
Dual signal processing UVIR ARC rejection algorithm, UV signal Time Domain Signal Analysis, IR signal processing angstroms solar blind 4.45 micron solar blind Quick fire response Heated optic Multiple fuel verified

30 X3301 Multispectrum Infrared Flame Detector
Multiple Patents Wavelength Algorithm Digital signal Processing Heated optics Extended Cone of Vision Combines the longest detection range with the best false alarm rejection capabilities Multiple fuel verified, lowest cost of coverage all fuels

31 Flame Detectors Optical Integrity
Calibrated MAG-Oi, no test lamp required! Automatic and manual optical integrity test verified to perform a calibrated test of the detector operation. Manual and MAG-Oi perform system activation

32 EQP – Field Devices - Flexible
EQ3700DCIO Eight channel Direct Current Input/Output module. EQ 3720RM Eight channel relay output module EQ3710AIM Eight channel Analog input module EQ3720IPM Intelligent Protection Module

33 EQP – Controller Details
Controller logic processing 10X faster than LCU. New LON transceivers process field data 2X faster than LCU. 8 onboard dry contact inputs. 8 onboard relay outputs. Dedicated fault relay. Dual media Control-Net option for Allen-Bradley compatibility. Future Expansion capability. 2 onboard serial interfaces for configuration and data exchange. 8 Dry Contact Inputs 8 Relay Outputs Fault Relay Field Device Network (LON) Field Device Network (LON) EQP CONTROLLER Dual Media ControlNet Interface (Optional) Future Expansion Capabilities Onboard Serial Interface RS-232 Configuration PC RS-485 Modbus RTU Master

34 EQP System Overview EQP Controller is the start and end of the network. Local Operating Network & Signaling Line Circuit (LON/SLC) Up to 2000 meters and 60 devices in base configuration. Power Supply Monitor, power supplies, battery charger, etc. EQP CONTROLLER AB MB DI DO Power Supply Monitor Battery Charger & PS

35 EQP System Overview - Loop
LON Diagnostics and Integrity testing done by the controller. Network extenders allow for the LON/SLC to grow. An additional 2000 meters distance per extender. An additional 60 devices per extender Network Extender EQP CONTROLLER AB MB DI DO Power Supply Monitor Battery Charger & PS

36 EQP System Overview - Flame
Initiating Device Circuits (IDC) UV High Temp Detector X2200 UV Flame Detector X2200 UV/IR Flame Detector X5200 X3301 Flame Detector IR Flame Detector X9800 Flame detection from a full range of technologies. IDC Provides two channels for supervised inputs from heat detectors, smoke detectors, etc. Quantum UV detector. Quantum UV/IR detector X3301 Multi-spectrum IR detector NFP IR detector Network Extender EQP CONTROLLER AB MB DI DO Power Supply Monitor Battery Charger & PS

37 EQP System Overview - Gas
Initiating Device Circuits (IDC) UV Flame Detector UV/IR Flame Detector X3301 Flame Detector IR Flame Detector Gas detection from a full range of technologies. PIRECL provides IR hydrocarbon detection OPECL open path DCU provides 4-20 ma input capability for toxics and special purpose detectors. DCUEX provides input capability for catalytic sensors. Network Extender Eclipse PIR Gas Detector Digital Com. Unit DCU EQP CONTROLLER AB MB DI DO Digital Com. Unit DCUEX Power Supply Monitor Battery Charger & PS

38 EQP System Overview - Flex I/O
Initiating Device Circuits (IDC) UV Flame Detector UV/IR Flame Detector X3301 Flame Detector IR Flame Detector Supervised output capabilities for signaling and releasing requirements. Signal Audible Module (SAM) provides two independent supervised output channels. Agent Release Module (ARM) provides supervision and control of one or two releasing solenoids. Network Extender Eclipse PIR Gas Detector Digital Com. Unit DCU Agent Release Module (ARM) EQP CONTROLLER AB MB DI DO Digital Com. Unit DCUEX Power Supply Monitor Signal Audible Module (SAM) Battery Charger & PS

39 EQP System Overview - Flex I/O
Initiating Device Circuits (IDC) UV Flame Detector UV/IR Flame Detector X3301 Flame Detector IR Flame Detector High density I/O Modules. DCIO provides eight channels that can be configured as either inputs or outputs. Relay module provides eight non-supervised relay outputs. AIM eight channel analog input module IPM intelligent protection module Analog Input Module(AIM) Network Extender Intelligent Protection Module (IPM) Eclipse PIR Gas Detector 8 Channel DCIO Relay Output Module(RM) Digital Com. Unit DCU Agent Release Module (ARM) EQP CONTROLLER AB MB DI DO Digital Com. Unit DCUEX Power Supply Monitor Signal Audible Module (SAM) Battery Charger & PS

40 S3 Software Package PC-based System Software package
Data Collection Distributor (DCD) Configuration of field devices Creation of user logic (IEC ) offline simulation/testing of user logic on line logic monitoring creates drawings of the logic Diagnostics Alarm/Event logging Custom Graphics customer specific graphics of plant layout, etc.

41 EQP – Questions & Answers
Smaller Faster Smarter