1 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 SCADA Master Engineering Workstation Running WinECP RS485 Multidrop DNP3.0 Connection for SCADA Data 10-Byte Connection for WinECP Alternate Configuration 10-Byte RS232 pass through connection for WinECP Connection for SCADA Data Application Note #1004-01R2 Orion Serial-to-Serial Pass-Through to DPU/TPU2000R Relays The following slides detail how Orion and WinECP must be configured to set up a pass through connection as shown here

2 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 Using NovaTech Communication Director (NCD) offline, set up one of the rear ports as an “MMI Interface” port. This is required because the front port on Orion is fixed at 19.2kB and WinECP cannot support a baud rate that high. Note: Accessing Orion via dial-up or Ethernet is also possible. This note details only direct physical connection via RS232. Set the comm parameters of the MMI Interface port to the same parameters as the comm port on the PC.

3 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 Set the comm parameters of the Passthru port to the same parameters as the comm port on the DPU2000R relay Select “Passthru Interface” on the port where the DPU2000R relay will be attached. Some versions of NCD refer to “Passthru Interface” as “Direct Interface Client”.

4 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 Pass Through configuration complete. Now download configuration to Orion.

5 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 While online with Orion in a terminal emulation session, make selections to get to Pass Through mode. Select the port desired for pass through. When in Pass Through Mode, close out the session, but not using CTRL-X. This will leave the port open for pass through.

6 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 Open WinECP, select Direct Access Make sure comm parameters match the ones set on Orion. Connect. Note: If multiple DPU2000R units are connected to the Pass Through port on Orion, select desired unit number.

7 NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem, PA 18017 610-814-2610 DPU2000R should come up on-line, as shown here.


Download ppt "NovaTech Utility Solutions 15541 West 110 th Street Lenexa, KS 66219 913-451-1880 www.novatechweb.com Headquarters Office 3998 Schelden Circle Bethlehem,"