Presentation is loading. Please wait.

Presentation is loading. Please wait.

IMMW14, Ferney Voltaire, 26-29 September 2005 (slide 1/35) Experience with configurable acquisition software for magnetic measurement.

Similar presentations


Presentation on theme: "IMMW14, Ferney Voltaire, 26-29 September 2005 (slide 1/35) Experience with configurable acquisition software for magnetic measurement."— Presentation transcript:

1 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 1/35) Experience with configurable acquisition software for magnetic measurement M Gateau, M Marchesotti, A Raimondo, A Rijllart, H Reymond 1.Introduction 2.SM18 test benches facility 3.Test Master 4.Hardware Recognition System 5.Automation of the magnetic measurements 6.Conclusions

2 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 2/35) Introduction SM18

3 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 3/35) Mandate of the magnet test facility: - 1232 dipoles + 460 quadrupoles have to be cold tested at CERN - 12 benches built, organized in 6 clusters of 2 benches (SM18 building) - Wide range of local (per cluster) or shared (mobile rack) equipments - Magnet presence on the bench VS number of tests to execute Introduction

4 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 4/35) Constraints for the tests & measurements: - Several applications have been developed to assist the tests and measurements - Fast and easy setup of the applications - Taking into account specific calibration of the used devices - Limit as much as possible the manual edition of the configuration files - Traceability of the used equipments is requested by the QA rules Introduction

5 SM18 test benches facility IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 5/35) The hardware side … Each cluster is made of : DAQ electronic racks MM rack and systems ( TRU, AMPLI …) HV mobile rack 14kA, 600A, 60A power supplies LOSS monitor multimeters PLC ( security for PS & CRYO ) …

6 SM18 test benches facility IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 6/35) … and the software side The SM18 CR hosts 6 supervision posts : Test & sequence of tests editor Management of the tests Data viewers & analysis Alarms monitoring & logging …

7 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 7/35) Control Room Test Bench - MMP - HVTEST - POWER - LOSS - DVM_DAQ - PDI - MMP - HVTEST - POWER - LOSS - DVM_DAQ - PDI - HF - LF - POWER - HF - LF - POWER TEMA DAQ applicationsMM applications -TEMA - HRS - TTE - ALARM -TEMA - HRS - TTE - ALARM

8 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 8/35) Definition of a Test: From the TEMA point of view, a test is : - A list of commands - From a set of pre-defined commands, dedicated to an application - Used to execute a measurement with a list of specified equipments - On a local test bench

9 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 9/35)

10 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 10/35)

11 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 11/35)

12 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 12/35) Definition of a Sequence: From the TEMA point of view, a sequence is : - A list of tests - Used to execute a set of measurements & to drive the equipments - On a local test bench

13 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 13/35)

14 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 14/35)

15 Test Master IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 15/35) The TEST MASTER fulfills the first 2 constraints: - Management of several applications to assist the tests and measurements - Fast and easy setup of the applications What about : - Calibration parameters of the devices - Manual edition of the configuration files - Traceability

16 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 16/35) ProblemSolution Calibration parameters Manual edition of the configuration Traceability Database Auto configuration Identification

17 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 17/35) Hardware Recognition System

18 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 18/35) Identification Electronic of the DAQ system Hardware Recognition System

19 IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 19/35) Identification 15m coil shaft used for magnetic measurements

20 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 20/35) Identification Cryogenic Feed Box used to cool down the magnets

21 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 21/35) Identification The MOBIC from SIEMENS - Bar code scanner - Industrial portable computer - Wireless communication - Connected to the equipment DB

22 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 22/35) Calibration databases The calibration data are taken from : - CFB & magnet temperature probe coefficients DB - Coil coefficients DB - Power supply DCCT DB - …

23 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 23/35) Auto configuration A set of scripts have been developed to : - Compare the needed & present equipments for a dedicated test. - Access to the calibration DB and generate setting files for the dedicated applications. - Build and transfer on the local test bench workstation the final configuration file.

24 Hardware Recognition System IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 24/35) But what about the Magnetic Measurements … … at SM18 the MM are managed by the MMP6 application

25 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 25/35) MMP6 is made of 4 modes of use: The HARDWARE mode: Selection of the equipments Hardware configuration Test of the communications Test of the equipments

26 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 26/35) The RUN mode: Selection of the magnet type Selection of the measurement param. Selection of the current cycle

27 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 27/35) The MEASUREMENT mode: Execution of the current cycle Control of the equipments Execution of the MM Reading of the integrators Saving the data

28 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 28/35) The DISPLAY mode: Analysis of the data Info. about over range / out of limits Archiving of the raw data & results

29 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 29/35) From the TEST MASTER … … to the MM analysis

30 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 30/35) From the TEMA: Selection of the bench (1/2) Selection of the test to execute (ie : MM) Click on Run Test button Then all the following actions will be done automatically …

31 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 31/35) On the HRS: Extraction of the present equipments from the DB Comparison with the needed one for this MM Extraction of the calibration parameters Configuration file generation for MMP6 Transfer of the config. file on the cluster workstation

32 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 32/35) On the cluster workstation: Launching of the MMP6 application Execution of the commands for this test

33 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 33/35) On MMP6: Execution of the HW test of the equipments Execution of the magnetic measurement Display & online analysis

34 Automation of the magnetic measurements IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 34/35) From the users: Checking of the MM status & limits Acceptation of the test Archiving of the raw data

35 Conclusions IMMW14, Ferney Voltaire, 26-29 September 2005 hubert.reymond@cern.ch (slide 35/35) - The integration of the Test Master, Hardware Recognition System and MMP6 satisfies the constraints specified for the test benches facility. - The full system is in use since few month. The performance is very satisfactory, with a good reliability. - A lot of time has been saved during the phases of measurement and software configuration. - The experience of HRS will be taken as an example in the view of an adaptation for the LHC.


Download ppt "IMMW14, Ferney Voltaire, 26-29 September 2005 (slide 1/35) Experience with configurable acquisition software for magnetic measurement."