Clean and Pure steam in the Biopharm industry

Similar presentations


Presentation on theme: "Clean and Pure steam in the Biopharm industry"— Presentation transcript:

1 Clean and Pure steam in the Biopharm industry
Kieran O’Keeffe European Business Manager High Purity Products Spirax Sarco Ltd.

2 Typical Steam Circuit Steam Space Heating System Tank Process Vessel
Boiler Feed Pump Feed Tank Make-up Water H/Exchanger Condensate Steam Process Vessel Space Heating System

3 Driving standards Filtered Clean Pure 3A’s
UK Heat preserved foods guide FDA (Materials) Clean EN285 HTM2031 / 2010 FDA (Material) Pure EN285 HTM2031 / 2010 ASME BPE FDA (Material) FDA cGMP USP ISPE

4 Pure Steam Generation Pure Steam Generator cGMP, ISPE, BPE designed
3 phase moisture separation External compact evaporator column Generation Capacity from 50 kg/6T/hr Units can be Electric or Steam/Steam

5 Requirements of the system
“It is essential that that the steam is delivered to the point of use is of the correct quality and purity for the process” Three areas of design should be considered; Production Distribution Point of use

6 Quality and purity Quality V’s Purity Dryness
Dryness of >95% is essential Excess moisture can cause; - Damp loads in porous materials - Uneven temperature distribution in non-porous loads - Uncontrolled chemical composition of steam Will have the effect of not sterilising correctly

7 Quality and purity Quality V’s Purity Steam Dryness Testing procedure
D= (T1-T0)(4.18Mw+0.24) _ 4.18(Ts-T1) LMc L T0 = intial temp of water in flask T1 = final temp of water in flask Ts = average temp of water and condensate in flask Mw = Initial mass of water in flask Mc = mass of condensate collected (kg) L = latent heat of dry sat steam at temp Ts (kJ kg-1)

8 Quality and purity Quality V’s Purity Superheat
Superheat should not exceed 25 deg C (77 deg F) Problems incurred with Superheat include - Poor heat penetration resulting in Failure to sterilise - Scorching of textiles and paper - rapid deterioration of rubber

9 Quality and purity Quality V’s Purity
Steam Superheat Testing procedure Superheat content = temperature of steam in the expansion tube – temperature of boiling water at local atmospheric pressure

10 Quality and purity Quality V’s Purity Non-condensable gases (NCG)
Gases which can not be liquefied by compression under the range of temperature / pressure experience in the sterilising process. NCG’s should not exceed 3.5% by volume High NCG content can cause Bowie and Dick test failure

11 Quality and purity Quality V’s Purity
Non-condensable Gas Testing procedure Fraction of NCG = vol of gas collected in the burette / vol of water collected in the measuring cylinder.

12 Specific Volume Vs Pressure Saturated Steam
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 3 4 5 6 7 8 9 10 11 12 13 14 Pressure (bar g) Specific Volume (m3/kg)

13 Steam Properties Steam Tables

14 Distribute at High Pressure
Smaller bore steam mains needed and therefore less heat (energy) loss due to the smaller surface area. Lower capital cost of steam mains, both materials such as pipes, support work and labour. Lower capital cost of insulation (lagging). Dryer steam at the point of usage because of the drying effect of pressure reduction taking place.

15 Pipe Distribution Greater Cost Greater Heat Loss
Greater Volume of Condensate Formed Lower Pressure to Steam Users Not Enough Volume of Steam Water Hammer and Erosion

16 How is pipe sized ? On the basis of: Steam Velocity Pressure Drop

17 Steam Pipe Sizing Chart (kg/h)
Pipe Sizing Chart Velocity Steam Pipe Sizing Chart (kg/h)

18 Pipeline Capacity and Pressure Drop
Fluid Flow P2 L

19 Steam Line Drainage

20 Clean and Pure Steam Distribution Condensate removal Adequate Support

21 Clean and Pure Steam Distribution Condensate removal
Steam traps should drain vertically downwards to avoid condensate hold up

22 Ineffective, and Proper Drain Points
Steam Flow Condensate Correct Incorrect Cross Section Pocket Steam Trap Set 25/30m Steam Flow Cross Section Steam Trap Set

23 Clean and Pure Steam Distribution Steam take-off

24 Steam Line Reducers Condensate Correct Incorrect Steam

25 Steam Take - off Shut Off Valve Trap Set Main Drop Leg

26 Recommended Support Spacing

27 Expansion Chart for Mild Steel Pipe
Temperature difference oC/metre Length of pipe (mm) Expansion of pipe (mm) Temperature of Saturated Steam

28 Warm up load/running load per 50m of pipe``
Ambient temperature 20  C, insulation efficiency 80% Lower figures represent running loads

29 Questions