The Fall Builders’ Forum Part 9 Energy Efficiency and Ventilation Regulations “Effective December 19 th, 2014”

Similar presentations


Presentation on theme: "The Fall Builders’ Forum Part 9 Energy Efficiency and Ventilation Regulations “Effective December 19 th, 2014”"— Presentation transcript:

1 The Fall Builders’ Forum Part 9 Energy Efficiency and Ventilation Regulations “Effective December 19 th, 2014”

2 Builders’ Forum Introduction (5 min) Overview of Changes (5 min) Envelope (15-20 min) HVAC / SWH (5-10 min) 9.32 – Ventilation (15 min) Compliance Options (10 min) Closing Remarks (10 Min ) Additional Questions

3 BCBC Energy Requirements (current to December 18, 2014) Part 9 (Houses and Small Buildings) Prescriptive Insulation tables EnerGuide 77 No requirement for professionals Part 10: Energy Efficiency current requirements

4 BCBC Energy Requirements (current to December 18, 2014)

5 BCBC – December 19 th, 2014 Current Part 9 Insulation tables (Table 10.2.1.1.A & Table 10.2.1.1.B) deleted Current reference to EnerGuide 77 deleted New admin section 2.2.8. sets out Information required for energy compliance by performance path 5

6 Prescriptive path – In-cavity Insulation Table Performance path – EnerGuide model – 77 Prescriptive path – Effective RSI-value Table – Trade-off Options – with / without HRV Performance path #1 – EnerGuide model – better than reference building Performance path #2 – NECB Current to Dec. 18, 2014As of Dec. 19, 2014 Compliance Paths Single Family Home

7 December 19 th, 2014 New insert to Section 9.32. Ventilation New Section 9.36. Energy Efficiency – Incorporates NBC 9.36. as a new section of the BC Code Current Section 9.36. (Secondary Suites) becomes 9.37. Section 9.37. Objectives and Functional Statements – Renumbered to 9.38. 7

8 BCBC Energy Requirements (as of December 19, 2014)

9 Mid-stream amendment to the 2012 BC Building Code developed by the NRC. ~110 pages Largest Code change in the history of the BC Building Code Multiple pathways to compliance –Several options for specific building types –‘Systems approach’ to prescriptive req’s –Performance-based options available What is Section 9.36?

10 Treats the building as a system Enables performance- based design Removes barriers for new technologies The GREEN of Section 9.36

11 Additional attention to detail at design stage Possible expansion of design team to include all sub trades now A whole new Code to purchase, understand, and apply (NECB) Additional items in Building Permit submission A new normal What It Means For Designers / Builders

12 9.36. Scope & Application 9.36.1.1. Scope This section is concerned with the energy used by buildings through – The building envelope heat losses (9.36.2), – Heating/ ventilation systems (9.36.3), (9.32), and – Domestic hot water (9.36.4) 12

13 The Building Envelope BCBC 9.36.2

14 Focus is on total building performance, not just thermal insulation anymore Heat transfer and air leakage between conditioned space and unconditioned space Windows must conform to Section 9.7 Properties of insulation, location and installation of air barriers, and vapour barriers must conform to Section 9.25 Scope + Application Building Envelope

15 Nominal Insulation

16 Effective Insulation Insulation in the framing cavity achieves continuity of effective Insulation, and is only a component in the assembly.

17 Climate Zones 17

18 Prescriptive path: Requirements vary whether or not an HRV is installed Table with minimum effective RSI-values Look-up tables for most common assemblies, and information on how to calculate them and others are provided in the Appendix Breaking each wall apart to individual components 9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies

19 Effective RSI-values – without HRV 9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Table 9.36.2.6.A

20 Effective RSI-values – with HRV 9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Table 9.36.2.6.B

21 Example: Wall 1: 170 m 2 2x6 @ 16” o/c, R-19 batt insulation; gyp bd. inside, plywood sheathing, rain screen, cement stucco: From table A-9.36.2.6.(1)A: 2x6 @ 16” o/c, R-19 batt insulation effective R-value = 2.36 Additional layers (values from Table A.9.36.2.4.(1) D Interior air film 0.12 Gyp bd. 0.08 Ply sheathing 0.10 Rain screen cavity 0.15 Stucco 0.08 Exterior air film 0.03 Total: 0.50 Total effective RSI = 2.86 This wall assembly will work in Zone 4 Wall Assembly Calculation Example

22 Major structural penetrations through assemblies are permitted – but total area must not exceed 2% Major allowable penetrations include balcony slabs, beams, columns, and minor ornamental structural elements. Minor penetrations include Pipes, ducts, through- wall equipment vents are not considered in the 2%. 9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies

23 RSI effective vs. RSI nominal RSI eff ≠ RSI nom

24 Effective R-Value

25

26 Look-up tables for common assemblies, and information on how to calculate others (9.36.2.4) Calculator - Canadian Wood Council – Wall Thermal Design Calculator

27 Continuity of Insulation

28 Insulation must be continuous across the entire envelope – but this does not mean continuous insulation across face. Another measure to reduce Thermal Bridging Applies to building components such as partitions, chimneys, fireplaces, and columns and beams along exterior walls, but not to stud framing and ends of joists (accounted for by effective R-value calculation). Continuity of Insulation

29 9.36.2.5. Continuity of Insulation 9.36.2.5. (7) ducts, plumbing pipes, electrical or communication conduits placed within the insulated portion of a floor or ceiling assembly must have an effective insulation level not less than RSI 2.78 (R-15.78). This applies to attics, unheated crawlspaces, etc.

30 9.36.2.5. Continuity of Insulation Ducts outside the heated envelope must be insulated to the same effective insulation level as required for walls above grade ✖ ✖

31 Alternative to placing ducts outside the heated building envelope: insulating the attic and making it conditioned space. Point to remember: The insulated roof section will now have to be the RSI value for your Zone. (cathedral ) 9.36.2.5. Continuity of Insulation

32 Continuity of Insulation

33 Unheated floor slabs must be insulated min. 1.2m horizontally or vertically down from its perimeter, with a thermal break along edge of slab a min. 50% of required insulation 9.36.2.8. Assemblies In Contact With Ground

34 Airtightness

35 9.25 currently requires an airtight building envelope 9.36 addresses construction of air barrier details because of the heat loss implications. Testing is NOT required. Air barriers must be continuous: across joints, between assemblies, and around penetrations. Airtightness

36 Joints in panel-type air barrier materials must be sealed by: Caulking, Sealants, Spray foam Gaskets Tapes Airtightness

37 Flexible sheet air barrier materials require all joints to be: lapped at least 50 mm (2”)Not 11/2”, and structurally supported sealed, and structurally supported Sealants must be non-hardening

38 Airtightness

39 HVAC + Service Water Heating BCBC 9.36.3 + BCBC 9.36.4

40 Heating systems must be designed in accordance with good practice (as per 9.32 & 9.33) Systems not referenced in 9.36 must be designed in accordance with requirements of the NECB Heating and air-conditioning equipment must be located inside the conditioned space, unless it is designed to be located outside Equipment efficiency set out in Table 9.36.10 (HVAC) and Table 9.36.4.2 (Service Water Heating) HVAC + Service Water Heating Scope + Application

41 All piping/ducts must be located inside the conditioned space. If located outside or within an exterior wall, the piping/ducts must be insulated to same level as required for above grade walls Continuity of Insulation HVAC + Service Water Heating

42 ✔ Ducts outside the heated envelope, or within an exterior assembly: All joints in the ducts must be sealed with sealant, mastic, or foil faced tape Fabric duct tape is not permitted Continuity of Air Barrier HVAC + Service Water Heating

43 Heat pumps with supplementary heaters – controls should prevent operation of supplementary heater when the heat pump can supply the full heat load Heating & cooling systems with separate controls must prevent both cooling & heating to be activated simultaneously Heating and air conditioning equipment must be located inside a conditioned space, unless it is designed to be installed outside. Temperature Controls HVAC + Service Water Heating

44 The first 2 m of piping from a storage tank or heater must be insulated with pipe insulation If hot water piping system has recirculation, the entire system must be insulated. If piping is located outside the heated envelope, it must be insulated to no less than the effective R-value of exterior walls. Hot Water Piping HVAC + Service Water Heating

45 Ventilation BCBC 9.36.3.9 + BCBC 9.32

46 Exhaust only ventilation acceptable New Principal Fan Sizing Rule Ventilation air must be distributed to each bedroom and a common area 4 acceptable options Principal System –must run continuously Crawlspace Ventilation Required Credit for very short bath fan exhaust ducts Ventilation Scope + Application

47 Ventilation Principal Ventilation System Exhaust Fan Based on bedroom count & square footage Minimum exhaust fan air-flow rate in Table 9.32.3.5

48 Ventilation Kitchen & Bath Fans Principal exhaust fan capacity @ 50 Pascals Designed to run continuously Controlled by dedicated switch Clearly marked “principal Ventilation Exhaust Fan” Two settings: on & off Accessible for servicing If capable of running at multiple flow rates, must have a separate switch so low rate is not less than required Sound rating not to exceed 1.0 sone

49 Ventilation Kitchen & Bath Fans Exhaust must be installed in every kitchen and bathroom Unless these are served by principal ventilation system, the Minimum flow rate is as per Table 9.32.3.6

50 Principal exhaust fan sized to Table 9.32.3.5; continuous operation Furnace fan must run continuously Supply air drawn into furnace return; limits on supply duct 9.32.3.4 (2) Supply with Forced Warm Air Heating

51 9.32.3.4 (3) HRV Supply with Forced Warm Air Heating

52 9.32.3.4 (4) Independently Distributed HRV System Dedicated supply ducts to each bedroom and to each floor At least one exhaust located 2 m above upper floor

53 Ventilation

54

55 Only applicable to one storey dwelling (<168 m2 with no forced air heating) Passive inlets must be a min. 1.8m above floor Each bedroom must have one inlet with unobstructed vent area of 100 mm diameter At least one common area must have an inlet 9.32.3.4 (6) Passive Supply

56 Ventilation 9.32.3.7 Heated crawlspace ventilation If crawlspace is heated by ducted forced air heating, it must be connected to floor above by at least one transfer grille (25cm2) for each 30m2 of crawlspace area Note: Crawlspace ventilation in this section must not be confused with exterior ventilation of unheated crawlspace

57 Ventilation 9.32.3.8 Ducts Exhaust and supply ducts: Must be sized as required by manufacturer & equivalent diameter as per Table 9.32.3.8 (3) Need to be air-sealed Insulated & provided with vapour barrier

58 Ventilation Future standard

59 Compliance Part 9 Building Energy Regulations in BC

60 Review of 9.36 Part 9 Building Energy Regulations in BC Effective December 19, 2014

61 Compliance Requirements for all Pathways Design Verification Report Drawing Submission

62 Envelope section drawing(s) to indicate Prescriptive requirements found in the Tables 9.36.2.6.A/B and Tables 9.36.2.8. A/B. Show all envelope insulation and components with notes indicating the Effective Thermal Resistance (RSI) Value of the Assembly. Both above and below grade. If you have a feature wall then you will be required to show all of your wall assembly for this wall as well the other three typical assemblies. Compliance Requirements for all Pathways

63 Compliance Requirements for all Pathways Window section drawing(s) to indicate Prescriptive requirements found in Tables 9.36.2.7.A./B./C. Show all Fenestration, Doors, and Skylights with notes indicating the Overall Thermal Transmittance (U Value) These are separate labels from the NAFS labels on windows now.

64

65 Compliance Drawing(s) to indicate Prescriptive requirements found in Table 9.36.3.10 and Table 9.36.4.2. Show all systems and types. This will include Space heating, Space cooling, and Service hot water. The notes on the plans will have to indicate the Performance Rating and Energy Source.

66 What is expected on the plans Completed information on the plans to confirm compliance Wall/ceiling assembles, with complete breakdown of the Effective RSI value Doors and windows indicated with the appropriate U-Values All heating and service water appliances are to be indicated on the plans

67 What to Expect from the municipality Building permit processing time will be increased accordingly to the permit and complexity to confirm compliance More inspections required by the Municipality for the first period of implementation of the new Code Training to the community provided by the Municipality to create a seamless cross over into the new Code

68 9.36 Energy Efficiency Questions? Thank you for attending todays session