Presentation is loading. Please wait.

Presentation is loading. Please wait.

ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.

Similar presentations


Presentation on theme: "ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying."— Presentation transcript:

1 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 1 DCNNG SA PO AIE 02.Mar.06 Trunk Extension Cables  Cable without connectors LBB 4116/00 100 m (328.0 ft) length  Cable with connectors LBB 4116/02 2 m (6.6 ft) length LBB 4116/05 5 m (16.0 ft) length LBB 4116/10 10 m (33.0 ft) length LBB 4116/15 15 m (49.2 ft) length LBB 4116/20 20 m (66.0 ft) length LBB 4116/25 25 m (82.0 ft) length  Set of 25 cable clamps LBB 4117/00  Termination plug for cable LBB 4118/00  Set of DCN Connectors LBB 4119/00 25 female and 25 male connectors  Set of 25 cable clamps DCN-DISCLM for Discussion Unit I & U Instructions

2 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 2 DCNNG SA PO AIE 02.Mar.06 Extension Cable wiring PIN 1 - Down- link screen (ground) PIN 2 - Down- link signal data from CCU (green) PIN 3 - Positive supply (max. 40V) (brown) PIN 4 - Up- link- signal data to CCU (white) PIN 5 - Up- link screen (ground) PIN 6 - Positive supply (max. 40V) (blue) I & U Instructions

3 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 3 DCNNG SA PO AIE 02.Mar.06 Trunk Splitter  1 DCN cable A 2 m long cable with a male connector.  2 DCN socket (trunk)A female socket for loop-through.  3 DCN socket (tap-off 1)A female socket to create a tap-off. The signal is automatically regenerated.  4 DCN socket (tap-off 2)A female socket to create a tap-off. The signal is automatically regenerated. Note: it’s never allowed to put trunk cables in parallel you always have to use a Trunk Splitter or Tap-Off Unit (Trunk Splitter Protected). 34 12 tap-off 2 tap-off 1 I & U Instructions LBB4114/00

4 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 4 DCNNG SA PO AIE 02.Mar.06 Trunk Splitter  Two signal regenerated tap-off outlets. * Trunk-in Trunk-out * * 1 nnn * Tap-off outlets which regenerating the digital signal. I & U Instructions LBB4114/00

5 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 5 DCNNG SA PO AIE 02.Mar.06 Tap-off unit (Trunk SplitterProtected)  1 DCN cable A 2 m long cable with a male connector.  2 DCN socket (trunk)A female socket for loop-through.  3 DCN socket (tap-off 1)A female socket to create a tap-off. The signal is automatically regenerated. Furthermore, the tap-off is protected for short-circuits and has a maximum load of 4.5 W.  4 DCN socket (tap-off 2)A female socket to create a tap-off. The signal is automatically regenerated. Furthermore, the tap-off is protected for short-circuits and has a maximum load of 4.5 W. 34 12 tap-off 2 tap-off 1 I & U Instructions LBB4115/00

6 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 6 DCNNG SA PO AIE 02.Mar.06 Tap-off unit (Trunk SplitterProtected)  Two signal regenerated AND protected tap-off outlets. * Trunk-in Trunk-out * * 12 Max. 4,5W I & U Instructions LBB4115/00

7 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 7 DCNNG SA PO AIE 02.Mar.06 1 23 4 5 6 9 10 11 Data Distribution Board  1 DCN cable A 2 m long cable with a male connector.  2 J10 jumper Two jumpers to select between system power supply or an external power supply.  3 S8 Dip switches A series of dip switches to configure: Description Numeric display Alpha-numeric display-1 with PC-only Alpha-numeric display-2 with PC-only Status display (GEO Vote) with PC-only Reserved Speak slowly singnaling Help signaling (booth 1 to 16) Help signaling (booth 17 to 31) I & U Instructions

8 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 8 DCNNG SA PO AIE 02.Mar.06 Data Distribution Board 1 23 4 5 6 9 10 11 7 8  4 RS232To Numeric Hall Displays. (see next slide).  5 InputA 20-pole parallel input connector to connect external devices.  6 InputTwenty solder pads for customized parallel input solutions.  7 Output Twenty solder pads for customized parallel output solutions.  8 Initialization button A button to initialize the address of the board. Next to the button is a LED that indicates the non-initialized mode. I & U Instructions

9 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 9 DCNNG SA PO AIE 02.Mar.06 Numeric Hall Display with Data Distribution Board Voting timer Nevertheless the "voting time" is given by DCN but only with PC-control Voting timer Nevertheless the "voting time" is given by DCN but only with PC-control Address 248 Address 248 I & U Instructions DCN-DDB

10 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 10 DCNNG SA PO AIE 02.Mar.06 Data Distribution Board 1 23 4 5 6 9 10 11  9 OutputA 20-pole parallel output connector to connect external devices.  10 Remote initialization A 10-pole connector for remote initialisation of the data distribution board.  11 External power supply Provision to connect an external power supply to feed the data distribution board from an external power source instead of the system power supply. I & U Instructions

11 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 11 DCNNG SA PO AIE 02.Mar.06 DDB used for speak slowly signaling. Booth and desk # not important. The first activated Slow action activates the first bit DOO. When more Slow actions are activated at the same time more bits are activated. (max. 8) Push on Slow button I & U Instructions

12 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 12 DCNNG SA PO AIE 02.Mar.06 DDB used for Help signaling. Push on Help button Booth 3 desk # Desk # not important. The first activated Help action within the booth activates the corresponding bit. I & U Instructions

13 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 13 DCNNG SA PO AIE 02.Mar.06 DDB used for remote functions.  External Switching device I & U Instructions

14 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 14 DCNNG SA PO AIE 02.Mar.06 Optical Network Splitter  The Network Splitter is used to create short-circuit proof tap-off points in the optical network. I & U Instructions LBB4410/00

15 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 15 DCNNG SA PO AIE 02.Mar.06 Optical Network Splitter  1 External power supply A socket for an (optional) external power supply (48 V DC). The external power supply only feeds the tap-offs. It does not provide powerto the trunk line.  2 Tap-off 1An optical network socket to create a tap-off. The tap-off is protected for short-circuits and has a maximum load of 2.5 A.  3 Trunk An optical network socket to connect the network splitter to the optical network.  4 Lid A lid that provides access to the jumpers. The rear side of the lid contains a label with explanation about the internal settings. 1 2 3 45 6 7 8 I & U Instructions LBB4410/00

16 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 16 DCNNG SA PO AIE 02.Mar.06 Optical Network Splitter  5 Status LED Yellow  6 Status LED Green  7 TrunkAn optical network socket to connect the network splitter to the optical network.  8 Tap-off 2An optical network socket to create a tap-off. The tap-off is protected for short-circuits and has a maximum load of 2.5 A. 1 2 3 45 6 7 8 I & U Instructions LBB4410/00

17 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 17 DCNNG SA PO AIE 02.Mar.06 Optical Network Splitter internal settings I & U Instructions LBB4410/00

18 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 18 DCNNG SA PO AIE 02.Mar.06 Fiber interface without address  The fiber interface is used to convert from plastic optical fiber cable (POF) to glass optical fiber cable (GOF) and vice versa to cover distances of more than 50 m in the optical network. I & U Instructions LBB4414/10

19 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 19 DCNNG SA PO AIE 02.Mar.06 Fiber interface without address  1 External power supply A connection for an optional external power supply  2 Control inputs for future use.  3 POF socketA POF socket to connect the Fiber interface to a POF cable.  4 Lid for future use.  5 & 6 Status LED’s See next slide  7 GOF socketA GOF socket to connect the Fiber interface to a GOFcable. 1 2 3 45 6 7 I & U Instructions LBB4414/10

20 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 20 DCNNG SA PO AIE 02.Mar.06 Fiber interface without address Status LED,s 5 6 I & U Instructions

21 ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Security Systems 21 DCNNG SA PO AIE 02.Mar.06 Accessories and Installation Equipment End of section SA PO Menu


Download ppt "ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying."

Similar presentations