Presentation is loading. Please wait.

Presentation is loading. Please wait.

Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a large-format printer. Customizing the Content: The placeholders in this.

Similar presentations


Presentation on theme: "Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a large-format printer. Customizing the Content: The placeholders in this."— Presentation transcript:

1 Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a large-format printer. Customizing the Content: The placeholders in this poster are formatted for you. Type in the placeholders to add text, or click an icon to add a table, chart, SmartArt graphic, picture or multimedia file. To add or remove bullet points from text, click the Bullets button on the Home tab. If you need more placeholders for titles, content or body text, make a copy of what you need and drag it into place. PowerPoint’s Smart Guides will help you align it with everything else. Want to use your own pictures instead of ours? No problem! Just click a picture, press the Delete key, then click the icon to add your picture. Water Quality Engineering project Christian Sanchez | Russell E Di Fiori | Pasadena City College Problem / Question How effective is your bio-reactor and how well did it perform removing nitrates from water? Hypothesis In theory the specific reactor that was built should be efficient enough to remove most if not all nitrate from water being cycled through the reactor. This is accomplished by removing Oxygen in the water by forcing it down through the inner coiled pipe, depletion of oxygen gives the bacteria perfect condition to thrive. Project Overview Building a reactor scaled down to process a small amount of water was a bit challenging. The actual build wasn’t so difficult but having to tune the reactor down to the flow rate was a bit more challenging, at first the results showed high nitrate levels but this was expected as the water had not yet been filtered throughout the Bio reactor. Having the water go through 75 ft. of tubing made it possible for the removal of oxygen, as the water is forced down through the tube levels of oxygen becomes lower and lower until it reaches the bottom once it reaches the bottom it then fills up all the way to the top and exits though the exhaust port. The inside was filled with wood chips although I found that it made the water a bit dirty but results showed it worked. Variables / Research What type of media was going to used to have production of bacteria? For my reactor I choose woodchips which I thought would be the best bet to have a surface area for bacteria to thrive. What type of design was going to be used? For my reactor a basic design was made with an intake, exhaust port water flows in and water flows out using no pump gravity only. Nitrate levels? Nitrate levels would have to be tested weekly for results. Materials Materials (detailed list)Quantity (be specific) 4 x 25 inch PVC pipe1 PVC end caps2 Intake Valve1 Exhaust Valve1 3/8 inch pipe75 FT Wood ChipsSmall bag 5mg/L water3 Gal. Procedure Step 1 Gather materials to build the reactor this took some pre – build planning. Step 2 Put together the reactor. Inside we have 75 ft of coil wrapped up. Step 3 Test the reactor for effectiveness and that it actually works. SUCCESS! Step 4 Over a period of time we need to test the results (Nitrate levels) Data / Observations Initial results shows a very high levels of nitrate which seem to be normal since no actual filtration had been started. A slight fix in the reactors exhaust port to have the water slow down to 22 ml/min seemed to show me better results. Results proved that slowing down the water was a good method better filtrating the water. Before the Third test I decided to slow it down a bit more to about 15ml/min and this show an excellent drop in the nitrate. Water with high concentration of Nitrate (14.6mg/l) was added and results showed that it still dropped to 10mg/l after water was introduced. Water flow was kept at the same speed and this eventually lead to a pretty low level of nitrate in the water thus showing that this reactor was a success. Results Initial Results showed 21.6 mg/L (starting results) First test shows 14.2 mg/L Second test shows a slight decrease at 10mg/L Third Test even greater success at 4.40 mg/L One final test shows 4.00 mg/L Conclusion Bio-Reactor proved to be efficient enough to remove most of the nitrate in the water being tested. Depleting the oxygen of the water before it even going through the media was a very good way of having the nitrate levels drop over time. Overall I was very satisfied with the reactor in both the way it looked and the efficiency that this reactor had. It also shows signs that it can ultimately process a lot more water than was currently processing.


Download ppt "Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a large-format printer. Customizing the Content: The placeholders in this."

Similar presentations


Ads by Google