E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors
2
Chillgard L Series The refrigerant monitoring industry leader Home of proven, reliable Photoacoustic Infrared Technology
3
Chillgard L Series Photoacoustic sensor is stable and sensitive Improved PIR sensing Sample system minimizes moving parts, no solenoid valves or mechanical flow switch RS-485 & Digital Signal Processing New advances in micro-machined technology Water and Corrosion resistant plastic enclosure
4
Chillgard L Series Features a new optical bench Micro-machined optics Significant technological advancement Used on all Chillgard LS and LE Gas Monitors Improved reliability 2-year warranty Backwards-compatible with existing units
5
Chillgard L Series - Flexibility Flexibility to meet: Refrigerant Monitoring needs Remote Signaling and Control Power Requirements Budget
6
Chillgard L Series Chillgard LS Refrigerant Monitor Economical low level monitoring of refrigerant gases Sensor unit with analog and digital output Chillgard LC Control Module Controls up to 8 Chillgard LS Sensors Multiple outputs and relays Chillgard LE Refrigerant Monitor Combined features of Chillgard LS and LC Gas Monitors within one enclosure Combined multi-point sensing and controlling
7
Chillgard LS Monitor Photoacoustic IR sensor Standard gases – R123, R134a, R11, R12, R22 Minimum detection level - 20ppm Single-point diffusion or 4- point pumped models
8
Chillgard LS Compliant with ANSI/ASHRAE 15 Compliant with ANSI/ASHRAE 15 UL approval Water- and corrosion-resistant plastic enclosure Easy operation, installation and maintenance 2-year warranty
9
Chillgard LS 24 VAC/DC or 110/220 VAC power 5 LEDs indicate power, fault and 3 levels of alarm 4-20 mA and RS-485 outputs (to Chillgard LC Controller)
10
Chillgard L Series – Sensor Board
11
Chillgard LS Optional Gases R400 and R500 series of refrigerants Blends of multiple refrigerants to obtain good thermodynamic properties in the chiller, with reduced corrosion and ozone depletion potential. Includes R404a, R410a, R407c, R507 Order with custom calibration Other refrigerants possible
12
Chillgard LS Accessories Accessories Unit-mounted strobe Calibration box Remote light towers Calibration kits Chillgard LC Controller
13
Maintenance and Repair No moving parts in diffusion-mode Chillgard LS MonitorNo moving parts in diffusion-mode Chillgard LS Monitor Optical bench is field-replaceable for convenient repair and for detection of a different refrigerantOptical bench is field-replaceable for convenient repair and for detection of a different refrigerant
14
Chillgard LS Optical Bench pumped bench diffusion bench
15
Chillgard LS Summary Low cost refrigerant sensor Improved PIR technology Easy to install, operate and maintain Can be stand-alone or used with Chillgard LC Controller
16
Chillgard LC Control Module Capable of controlling up to 8 Chillgard LS Sensors Easy-to-use digital display with 4-button keypad Provides gas reading, alarm status, calibration and fault diagnostics Water- and corrosion-resistant enclosure
17
Chillgard LC Features 4-20mA and RS-232 output 0-10 V point identifier output 4 relays - 3 levels of alarm + fault 85 dB horn, 100 dB horn option
18
Chillgard LC Control Board
19
Chillgard LS & LC Twisted pair RS-485, 18 GA wire up to 1000 ftTwisted pair RS-485, 18 GA wire up to 1000 ft Modbus protocolModbus protocol LC can communicate with up to 8 single-point LS monitors, two 4-point LS monitors, or any combinationLC can communicate with up to 8 single-point LS monitors, two 4-point LS monitors, or any combination
20
Chillgard LC Wiring Home-run communication wiring Bus communication wiring
21
Powering the Chillgard LS Power locally via 24 VAC or DC Power locally via 110/220 VAC optional supply Power via Chillgard LC Control Module
22
Powering the Chillgard LC 24 VAC or DC 110/220 VAC optional supply Can be used to power one Chillgard LS Monitor
23
Powering the Chillgard LC Transformer version Powers Chillgard LC Monitor and up to 5 Chillgard LS Sensors
24
Powering Chillgard L Series 24 VAC/DC available 24 VAC/DC RS 485
25
Chillgard L Series Power Options 110/220 VAC Available 110/220 V input input With internal 110/220 VAC power supply RS 485
26
Chillgard L Series Power Options 110/220 VAC Available 110/220 V input 4-conductor cable 24 VDC from LC With internal 110/220 VAC power supply For 1 sensor module, up to 100’ using 18 AWG wire
27
Chillgard L Series Power Options 110/220 VAC AVAILABLE LC transformer version 110/220 V Input RS 485 24 VAC RS 485 24 VAC RS 485 w/internal transformer Transformer version powers up to 5 diffusion Chillgard LS Monitors or two 4-point pumped Chillgard LS Monitors
28
Chillgard LC Accessories Unit mounted strobe Remote light towers Calibration kits
29
Chillgard LC Summary Low cost controller Controls up to 8 Chillgard LS sensors Multiple outputs Configurable to meet your needs Easy to install, operate and maintain
30
Chillgard LE Features Combined features of Chillgard LS and LC products in one enclosure Combined features of Chillgard LS and LC products in one enclosure Combined multi-point sensing and controlling
31
Chillgard LE Features Photoacoustic IR sensor Standard gases – R123, R134a, R11, R12, R22 Minimum detection level - 20ppm Single-point diffusion, single- point pumped or 4-point pumped models
32
Chillgard LE Features Complies with ANSI/ASHRAE 15 UL approval Water- and corrosion- resistant plastic enclosure Easy to operate, install and maintain 2-year warranty
33
Chillgard LE Features 24 VAC/DC or 110/220 VAC power 24 VAC/DC or 110/220 VAC power Easy-to-use digital display with 4-button keypad Provides gas reading, alarm status, calibration and fault diagnostics Water- and corrosion-resistant enclosure
34
Chillgard LE Features 4-20mA and RS-232 output 4-20mA and RS-232 output 0-10 V point identifier output 4 relays - 3 levels of alarm + fault 85 dB horn, 100 dB horn option
35
Chillgard LE Gases R400 and R500 series of refrigerants Blends of multiple refrigerants to obtain good thermodynamic properties in the chiller, with reduced corrosion and ozone depletion potential. Includes R404a, R410a, R407c, R507 Order with custom calibration Other refrigerants possible
36
Chillgard LE Summary Low cost refrigerant sensor Improved PIR technology Multiple outputs Configurable to meet your needs Easy to install, operate and maintain
37
Chillgard L Series Summary Effective: Meets ASHRAE standards for refrigerant monitoring Flexible: Configurable to meet application needs Advanced: Photoacoustic infrared bench design Efficient: Detects low levels of refrigerant gas with low cost of ownership