TrueZONE™Panels Training Module

Similar presentations


Presentation on theme: "TrueZONE™Panels Training Module"— Presentation transcript:

1 TrueZONE™Panels Training Module
Click For Next Slide To advance this module, click when this icon appears on the slide.

2 What you will learn Why Zoning? Current Zoning Situation
Features and Benefits TrueZONE™ Panels TrueZONE™ Panel Product Family Overview and Wiring Support Materials Click For Next Slide

3 Why Zoning? Click For Next Slide

4 2006 American Home Comfort Study
67% of US homeowners are uncomfortable in their homes at certain times of the year. Homeowners want Zoning! Contractor Knowledge and Education is Key Click For Next Slide

5 Homeowners Need Zoning
The #1 complaint from new homeowners after 1 year of living in a new home is uneven temperature in their house. “I just paid $400,000 for my home and it doesn’t heat & cool properly!” Click For Next Slide

6 2006 American Home Comfort Study
4 out of 10 who were offered purchased a zoning system. Very High Close Rate! Click For Next Slide

7 Homeowner Benefits Customer Comfort! Energy Savings/Eco-Friendly
Where you want it when you want it Comfortable upstairs and downstairs The convenience of a thermostat in each zone Energy Savings/Eco-Friendly Only Heat or Cool the rooms you use Click For Next Slide

8 Contractor Benefits Builder/Homebuyer Satisfaction
Improved Profit Margins Differentiation Product Easy to Access and Readily Available Easiest to Install and Operate Product Quality, Reliability and Performance Honeywell World Class Support Click For Next Slide

9 Why Honeywell Zoning? Brand Best in Class Improved Profit Margins
A name consumers know & trust Best in Class Innovative leader with easiest to install, highest quality systems Improved Profit Margins Differentiation Complete Product Offering Panels Dampers System Kits Support Trained Contractor Zoning Specialists Dedicated Zoning Technical Support Hotline: Click For Next Slide

10 Current Zoning Situation
Click For Next Slide

11 Zoning Current Situation
Problem Current zoning panels are complicated, requiring extra time and labor to install – leading to increased call backs. Pots, dipswitches and jumpers are difficult to use and can break easily making installation confusing and time consuming. Click For Next Slide

12 Current Market Call Backs
Research shows between 10% - 15% of all industry zoning jobs have a callback resulting in wasted time and money. Click For Next Slide

13 Far Better Situation - Zoning Made Effortless!
HZ311 HZ322 HZ432 TrueZONE Panels Replacing the TZ-4 and EMM Panels Click For Next Slide

14 Virtually Eliminate Callbacks!
Set Jumpers, 7% Thermostat Wiring 19% Set DIPS, 19% Air Noise, 1% Equipment Problem, 2% Panel Problem, 8% Equipment Wiring 12% Wiring Transformer, 4% UI Explained, 5% Damper Wiring 11% Configure OC, 3% Operation Explained, 2% Limit, low or high 1% Damper Operation Wiring TAZ, 2% 5% TrueZONE™ Reduces Callbacks by 87% Click For Next Slide

15 Features and Benefits TrueZONE™ Panels
Click For Next Slide

16 TrueZONE Key Features Intuitive Installer Setup — Easy-to-follow, digital display uses real language to guide installer through four simple steps*. 1) Select equipment type 2) Select heat/cool stages 3) Select number of zones 4) Select stage control Click For Next Slide *HZ432 and HZ322 only

17 HZ432 & HZ322 Advanced Setup Advanced Setup is not Usually Necessary
Basic configuration choices default the Advanced Setups for you But you can use Advanced Setup to tweak these settings Advanced Setup Configures: Stage timer (one for 2nd stage, and one for 3rd stage) Purge Timer (2, 3.5, or 5 minutes) AutoChangeover Delay (15, 20, 30 minutes) DATS High limit ( ) DATS Low limit (30-60) Type of Thermostat (Conventional or HP using O or B) Dual Fuel Balance Temperature (30-50) And more! Click For Next Slide

18 TrueZONE Key Features Standardized Checkout Procedure — Standardizes the checkout process so that every installer checks out in the same way, every time to ensure that all zones are operating correctly before leaving the jobsite. Only one installer needed for checkout. (HZ432 and HZ322 only) Click For Next Slide

19 TrueZONE Key Features Robust Push Terminals — Push-in terminal blocks wire in literally half the time compared to screw terminals — with no screwdriver required. Plus, wires lock-in to the terminals for a tight fit. Common-Sense LEDs — Indicate which zones are calling, what stage they are calling for (heat/cool) and when the emergency heat is on. Universal Application — TrueZONE panels work with virtually any brand equipment for zone control of conventional, heat pump or dual fuel systems. Click For Next Slide

20 TrueZONE Key Features Variable-Speed Fan Control — Reduces blower speed in cooling when one zone is calling. Discharge Temperature (DATS) Staging — Downstages equipment when discharge air temperature is near the limit. (HZ432 and HZ322) Advanced Dual-Fuel Operation — Offers dual-fuel changeover based on outdoor temperature and/or thermostat staging. (HZ432 only) Click For Next Slide

21 Installation Flexibility
Smaller Footprint — Gives installer the ability to mount TrueZONE panels anywhere — on the return duct, studs or wall next to the system. All panels are only eight inches wide. Fits on Returns, 2x4, or wall. Mounting holes in corners for wall mount, and in center for 2X4 mounting. Click For Next Slide

22 Easy Wire Routing Clean, Professional Installation — Wire channel allows installer to run wires on the side, top, bottom or backside of the panel and wire anchors help hold wires in place. Run wires in from top, bottom, sides, or behind panel. Wire tie anchors. For neat, secure installation Click For Next Slide

23 TrueZONE Key Features Highest Quality in Industry
Electronic Excellence 100% Surface mount technology 100% covered electronics Extreme reliability – even in very hot attics up to 165° Tested and operated to 220°: melted plastic, but panel still works! Best In Class Circuit Breaker Protection Use any size transformer to power many dampers Each zone is protected by its own circuit breaker - Patented Panel will continue to run even when one breaker trips Volt Meter Probe Troubleshooting Copper plate by each terminal can be used to check voltages Click For Next Slide

24 HZ311 Overview Click For Next Slide

25 HZ322 Overview Click For Next Slide

26 HZ432 Overview Click For Next Slide

27 Use Any Thermostat to Control Zoning System!
Click For Next Slide

28 TrueZONE™ Panel Product Family Overview and Wiring
Click For Next Slide

29 HZ432 Key Features and Wiring
Compatible with Variable Speed Blowers Reduces blower speed when 1 zone is calling Or when 25% or fewer zones are calling when more than 4 zones are controlled Dual Fuel Changeover by OT temperature Or by OT Temperature and Call for 2nd stage heat Multi-Stage OT Lockout Connect an OT sensor to panel When outdoor temp rises above set temp (10°-50°F) 2nd and 3rd stage heat is locked out on non-dual fuel systems Click For Next Slide

30 HZ432 Configuration Quick Setup in real language reduces install time!
No dips, pots or jumpers! Intuitive setup with clear display Intelligent…it configures itself based on your selections Most setups require only 5 menu choices! Advanced configuration available for advanced control Click For Next Slide

31 HZ432 Other Features DATS Limits DATS Multi-Stage Inhibit
° F in heat 30-60° F in cool DATS Multi-Stage Inhibit Locks out 2nd and 3rd stage when close to high or low DATS limits Powers Many Dampers Size the transformer for dampers and panel (10 VA) Control up to 5 ARD or ZD per zone Or up to 26 RRD per panel! Click For Next Slide

32 HZ432 Other Features Auto-changeover Delay Purge Configuration
Can be set to 15, 20, or 30 minutes Purge Configuration The purge time can be configured to be 2, 3.5, or 5 minutes Multi Stage Control The panel can control multi-stage conventional heat pump and conventional equipment by: A multi-stage thermostat Percentage of zones calling Timer Click For Next Slide

33 HZ432 Wiring Wire Thermostat and dampers to each zone:
Click For Next Slide

34 TrueZONE Key Features Intuitive Installer Setup — Easy-to-follow, digital display uses real language to guide installer through four simple steps*. 1) Select equipment type 2) Select heat/cool stages 3) Select number of zones 4) Select stage control *HZ432 and HZ322 only Click For Next Slide

35 TrueZONE Key Features Standardized Checkout Procedure — Standardizes the checkout process so that every installer checks out in the same way,every time to ensure that all zones are operating correctly before leaving the jobsite. Only one installer needed for checkout. (HZ432 and HZ322 only) Click For Next Slide

36 HZ322 Key Features and Wiring
Click For Next Slide

37 HZ322 Key Features and Wiring
Controls Conventional and Heat Pump Equipment Up to 2 Stages Heat, 2 Stages Cool Up to 3-Zone Panel Quick Setup with intuitive menu on display Intelligent…it configures itself based on your selections! Compatible with Variable Speed Blowers reduces blower speed when 1 zone is calling Click For Next Slide

38 HZ322 Other Features DATS Limits DATS Multi-Stage Inhibit
° F in heat 30-60° F in cool DATS Multi-Stage Inhibit Locks out 2nd and 3rd stage when close to high or low DATS limits Powers Many Dampers Size the transformer for dampers and panel (10 VA) Control up to 5 ARD or ZD per zone Or up to 26 RRD per panel! Click For Next Slide 38

39 HZ322 Other Features: Same as HZ432
Auto-changeover Delay Can be set to 15, 20, or 30 minutes Purge Configuration The purge time can be configured to be 2, 3.5, or 5 minutes Multi Stage Control The panel can control multi-stage conventional heat pump and conventional equipment by: A multi-stage thermostat Percentage of zones calling Timer Click For Next Slide 39

40 HZ322 Wiring Wires Just Like the HZ432, but without W3
Click For Next Slide

41 HZ311 Key Features and Wiring
Click For Next Slide

42 HZ311 Key Features and Wiring
Controls Conventional Equipment Up to 1 Stage Heat, 1 Stage Cool Up to 3-Zone Panel No configuration at all – Very, Very Easy! Quick Hookup Just strip the wire and push in Great for New Construction Small size fits anywhere Perfect for attic installations…up to 165°F! Click For Next Slide

43 HZ311 Key Features and Wiring
Powers Many Dampers Size the transformer to power dampers and panel (6.25 VA) Control up to 5 ARD or ZD per zone Or up to 26 RRD per panel Controls Conventional Equipment Up to 1 Stage Heat, 1 Stage Cool Compatible with Variable Speed Blowers Reduces blower speed when 1 zone is calling Click For Next Slide

44 HZ311 Wiring: Wire Thermostats and Dampers
Click For Next Slide

45 HZ311 Wiring Wire Equipment Click For Next Slide

46 Kits Comes with… Panel Transformer Discharge Air Temperature Sensor
Just add… Zone Dampers Bypass Dampers Click For Next Slide

47 Need Help? Warranty Honeywell Zoning products carry a 5-year limited warranty Technical Support 1(800)-TAT-TEMP M-F 7:00-4:00 CST On The Web Click For Next Slide

48 TrueZONE™ Support Materials
Click For Next Slide

49 TrueZONE Interactive Demos
Get more marketing, technical and install information and interactive demos online at Use as a part of your overall training package with customers, sales and counter staff. Click For Next Slide

50 TrueZONE™ Panels Knowledge Test
Now that you completed this training module, take the short quiz to test your knowledge.

51 Test 1. When asked, what % of US homeowners are uncomfortable in their homes at certain times of the year. a. 20% b. 56% c. 67% d. 85% 2. What is a homeowner benefit of zoning? a. Uneven temperatures in the home b. Only heat and cool the rooms they use c. Easy to Install and Operate d. Honeywell is a brand Homeowners trust

52 Test 3. Which TrueZONE™ Panels offer a digital display enabling a simple set up and check out process HZ311 Only HZ322 Only HZ432 and HZ311 HZ432 and HZ322 All panels have a digital display 4. Which TrueZONE™ Panel offers dual fuel as a built in capability? HZ432 HZ332 HZ311 All panels have a built in dual fuel capability

53 Test 5. TrueZONE Panels do not offer universal application. T F
6. What is warranty of a TrueZONE™ Panel? a. 2 Year b. 3 Year c. 5 Year d. There is no warranty on TrueZONE Panels 7. How wide are the TrueZONE Panels? a. 8” b. 10” c. 12” d. 14”

54 Test 8. How many zones can the HZ432 be expanded to?
9. TrueZONE Panels are rated to what temperature? 150°F 165°F 220°F 225°F 10. TrueZONE Panels use pots and dipswitches T F

55 Answer Key 1. C 2. B 3. D 4. A 5. F 6. C 7. A 8. D 9. B 10. F