Proposed Improvements to the Water System Infrastructure in the Anacostia Area of Washington, D.C. November 20, 2002 Prepared by Prepared for Our Customers, Council Members, Advisory Neighborhood Commissioners, and Concerned Stakeholders
2
2 Benefits from Proposed $40 Million Improvements Maintains water quality More reliable fire protection Improved water pressure Enhanced reliability for the community Addresses water, fire, and maintenance challenges at the St. Elizabeths campus Supports future development St. Elizabeths Hospital overlooks the Potomac and Anacostia Rivers.
3
3 Anacostia Service Area Challenges Low pressure in southern Anacostia (south of W Street, SE) Low pressure at St. Elizabeths campus Under utilization of water storage at Ft. Stanton Reservoirs Old water transmission system Aging equipment and building at Anacostia Pumping Station, constructed in 1913 Fire protection
4
4 Improvements in Anacostia North Anacostia South Anacostia
5
5 Low Water Pressure vs. High Water Pressure Ft. Stanton Reservoirs Low pressure acceptability threshold: 35 psi Optimal water pressure: 50–80 psi
6
6 43 psi25 psi34 psi42 psi Ft. Stanton Existing Reservoirs Before Conditions vs. After Conditions 35 psi – low pressure acceptability threshold 50–80 psi – optimum water pressure 63 psi54 psi63 psi71 psi Proposed 43 psi25 psi34 psi42 psi Pomeroy Road
7
7 Before Conditions vs. After Conditions, continued After Proposed Anacostia Tank Before Ft. Stanton Reservoirs
8
8 Planned Improvements 2005 2006 Pipes 2004–2005 Eliminating Dead Ends (in progress )
9
9 Proposed Improvements Anacostia Service Areas Plan of Action: Construct new Ft. Stanton Pumping Station Benefits: This pumping station and the tank will boost pressure in the southern portion of Anacostia Maximize use of the storage capacity at the Ft. Stanton Reservoirs Ft. Stanton Park Proposed pumping station
10
10 Proposed Improvements Anacostia Service Areas, continued Plan of Action: Construct 2 million gallon (MG) elevated storage tank in southern portion of Anacostia Benefits: Maintains optimal pressure Provides continuous water supply during peak demand periods Provides ample fire protection storage Provides emergency reserve in the event of mechanical failure to the pumping station Proposed tank
11
11 Proposed Improvements Anacostia Service Areas, continued Plan of Action: Replace 6,000 feet of 20" pipe along Minnesota Avenue, from Pennsylvania Avenue to W Street Benefit: Replace low pressure-rated pipe with higher rated pipe to meet higher pressure requirements
12
12 Proposed Improvements Anacostia Service Areas, continued Plan of Action: Replace 4,800 feet of 20" pipe along Martin Luther King Jr. Avenue, from Milwaukee Place to Upsal Street, SE Benefit: Replaces low pressure- rated pipe with higher rated pipe to meet higher pressure requirements
13
13 Proposed Improvements Anacostia Service Areas, continued Plan of Action: New 5,300 feet of 24" pipe along V or W Street, from Ft. Stanton Reservoirs to Martin Luther King Jr. Avenue Benefit: Will provide a secondary feed to the Ft. Stanton Reservoirs, and a looped transmission network for better circulation
14
14 Proposed Improvements Anacostia Service Areas, continued Plan of Action: Replace existing Anacostia Pumping Station with new station on existing site Benefits: Replaces 1913 station, with new state-of-the-art facility Existing station will remain operational during construction with no loss of service
15
15 Completed Improvements Anacostia Service Areas Plan of Action: Rehabilitate two Anacostia elevated storage tanks: Good Hope (completed) and Boulevard Tanks (in progress) Benefits: Complete repainting improves overall appearance Improves water quality Provides improved safety features for WASA operators Before rehabilitation After
16
Proposed Improvements … At a glance Replace 6,000' of 20" pipe along Minnesota Ave., from Pennsylvania Ave. to W St. PS Rehabilitate Good Hope Road Tank (completed) Rehabilitate Boulevard Tank at Massachusetts and Alabama Avenue (not shown, currently underway) Replace existing Anacostia Pumping Station New 5,300' of 24" pipe along W St., from Ft. Stanton Reservoirs to MLK Ave. Anacostia (North) Anacostia (South) Anacostia North/South Boundary (at W Street) Construct new Ft. Stanton Pumping Station Construct new 2 MG elevated storage tank at St. Elizabeths Replace 4,800' of 20" pipe along MLK Ave. from Milwaukee Pl. to Upsal St. N Pennsylvania Ave.
17
17 Increased water pressure To provide additional supply during peak usage periods For fire fighting purposes Emergency reserve in the event of mechanical failures in the system Additional capacity to support economic development Why Is Additional Water Storage Needed?
18
18 Relies on gravity to maintain pressures Minimal mechanical working parts involved and is less vulnerable to mechanical breakdowns Less vulnerable to power failure Emergency reserve for system outages Does not make noise or emit fumes More reliable fire protection Less costly to operate and maintain Lifespan is 50+ years Why an Elevated Storage Tank?
19
19 Yes, a pumping system. There are major disadvantages It’s mechanical and less reliable – Increased potential for failure – Requires complex multiple pump operations – more wear and tear – Requires a more comprehensive back-up source of power (generator) Potential for “water-hammer” that can cause pipe breaks Additional noise Are There Other Options?
20
20 Yes, “Do Nothing” option Continued low pressures in the service area Added risks from a fire protection perspective Limits future development Are There Other Options?, continued
21
21 High ground elevation Centrally located in relation to problem areas Close proximity to existing transmission pipes Location will support future development in Anacostia Why at St. Elizabeths?
22
22 Other Anacostia Projects Plan of Action: Continue ongoing programs – Eliminate cross connections – Eliminate dead end water pipes – Replace old valves – Rehabilitate water pipes
23
23 Project Costs for Improvements in Anacostia $ (in millions) Rehabilitate Good Hope and Boulevard Lane Tanks 0.9 Replace Anacostia Pumping Station14.6 New Ft. Stanton Pumping Station4.7 Replacement of pipes9.1 24" reinforcing pipes 4.1 2 MG Anacostia elevated storage tank 5.9 Total39.3
24
24 Construction Schedule ProjectDate Completed Rehabilitate Good Hope (completed) and Boulevard Tanks (in progress) Dec 2002 Replace 20" pipe along Martin Luther King Jr. Avenue from Milwaukee Place to Upsal Street, SEDec 2004 Replace 20" pipe along Minnesota Avenue from Pennsylvania Avenue to W Street Aug 2005 New 24" pipe along W Street from Ft. Stanton Reservoirs to Martin Luther King Jr. AvenueNov 2005 Construct new Ft. Stanton Pumping StationDec 2005 Construct 2 MG Anacostia elevated storage tank at St. ElizabethsJuly 2006 Replace Anacostia Pumping Station (on Minnesota Avenue) with new pumping station on existing siteDec 2006
25
Invite us to individual ANC and community meetings
26
Question and Answer Session
Similar presentations
© 2024 SlidePlayer.com Inc.