BCGCA3004B Construct Wall Framing. Wall Framing Building Code of Australia states that.

Similar presentations


Presentation on theme: "BCGCA3004B Construct Wall Framing. Wall Framing Building Code of Australia states that."— Presentation transcript:

1 BCGCA3004B Construct Wall Framing

2

3 Wall Framing Building Code of Australia states that

4 AS 1684.2 Scope Page 9 Section 1.1

5 AS 1684.2 Scope Page 9 Section 1.1 This means that this standard only applies the Residential Buildings (Class 1) or Garages & Carports (Class 10).

6 Wall Frame Members Parts of a frame perform specific functions - supporting live & dead loads - resist Racking Forces - resist Overturning Forces - resist Sliding Forces - resist Uplift Forces -Most members provide a face to accept linings (this means that member sizes may be limited)

7 Live Load

8 Dead Load

9 Racking Forces Wind

10 Overturning Forces Wind

11 Sliding Forces Wind

12 Uplift Forces Wind

13 Timbers Generally Used - Radiata Pine - Oregon (Douglas Fir) - Various Hardwood Species Various combinations of -timbers, -engineered wood products -materials such as steel may be usedWHY?

14 Structural Steel Radiata Pine Studs Engineered Timber (LVL) Lintels Galvanized Steel Strap Bracing Engineered Timber (I Beams) Deep Joists

15 Other more exotic Timbers such as Cypress Pine may be used. -Why?

16 Wall Frames Frames are classified into 2 categories 1.Load Bearing – They are structural frames, they transfer loads from roof or upper floor to the supporting floor frame. They can be either external or internal walls. 2.Non Load Bearing – - do not support any structural loads. - They support their own weight - Non structural loads doors and frame, kitchen cupboards, driers etc. - support some live loads eg Doors closing. Therefore there are some minimum requirements for these AS 1684.2 cl 6.3.5

17 AS 1684.2 cl 6.3.5

18 Basic Frame Components Refer page 187 TAFE Guide

19 Refer AS1684.2 cl 6.1.2

20 Frame Member Functions Plates Horizontal members that form the top & bottom of the frame. Bottom plate is usually 50mm for unseasoned timber 45mm for seasoned. Top plate is usually the same section size as bottom plate. For trussed roof top plates will be 75mm for unseasoned and 70mm for seasoned Top plate may be made up by 2 x 38 (35) Thicker top plates means that trusses or upper floor joists do not need to be placed direct over a stud

21

22 Plates AS 1684.2 cl 6.2.2

23 Studs Vertical members placed between the plates The set the wall height Studs in external frames resist Wind Loads Generally Stud sizes are 75mm or 100mm wide by 50mm or 38mm in unseasoned timbers and 70mm or 90mm wide by 35mm or 45mm in seasoned timbers. Required Stud sizes can be found in AS 1684.2 Supplements

24 Studs Continued Several Different types of Studs - Common - Door & Window - Secondary Jamb Studs - Jack & Short

25 Trimmers Horizontal members fixed between window studs and door studs. Referred to as Sill or Head trimmers Usually of the same section size bottom plates Openings wider than 1800mm require trimmers as specified in AS 1684.2 cl6.3.6.6 & table 6.3

26 Trimming Studs Run from Trimmers to Plates Used to block out Narrow Lintel Where use in conjunction with Lintel they may take structural loads Must be same depth as wall frame to accept finishes May also be referred to as “Jack”, “Soldier”, or “Short” studs

27 Noggins Horizontal Member cut between studs to keep them - straight - evenly spaced - prevent twisting - allows studs to carry higher load - Maximum spacing 1350mm, there walls upto 2700mm require only 1 row of noggins

28 Noggins AS 1684.2 cl 6.2.1.5

29

30 Blocking Placed at intersections of wall frames Normally 3 Blocks per intersection

31 Blocking AS1684.2

32 Lintels Also referred to as a Head Horizontal Load Bearing Member between Studs Purpose is to transfer loads to side of openings May be made of many materials - Timber - Engineered Timbers - Structural Steel or Cold Rolled Steel Sections

33

34

35 Bracing Provide lateral stability of Walls Provide resistance against racking forces induced direct wind loads Provide resistance to Roof loads induced onto top plates.

36 Bracing Methods Timber Bracing – 50 to 75 mm x 19 to 25mm checked into and nailed flush into face of studs. Braces must be installed in opposing pairs in external bracing walls. This method is virtually never used today. Rated 0.8 kN/m

37 Types of Bracing Perforated Metal Bracing - Installed in similar method as timber brace with a saw cut into the plates and studs. The brace is then nailed flush onto the studs and plates. Braces must be installed in opposing pairs in external walls. Rated 0.8 kN/m

38

39 Types of Bracing

40

41 Flat Metal or Hoop Iron Bracing 19mm Wide x 0.8mm Zincalume Two braces are fixed in opposite directions Fitted with Compression Clamps Rated 1.5kN/m

42

43

44

45 Types of Bracing Sheet Bracing Structural Plywood (Must be Stamped) Hardboard (Masonite) Fibre Cement Resists Strong Wind Loads Can be used on Narrow Panels – Why? Usually on external walls in cavity – Why? Minimum 7mm (Not Necessarily Correct) Must be nailed off as per AS 1684.2 Plate Steel can be used in High Wind Load Areas

46

47 Bracing AS 1684.2

48

49

50

51

52

53

54

55 Location of Bracing AS 1684 cl 8.3.6.6 states – Bracing should be evenly distributed and be provided in both directions – Should be placed initially at corners

56

57 Spacing of Bracing Walls AS 1684.2 Cl 8.3.6.7 states – For Single Storey Building or Upper Storey of Double Storey Buildings – Maximum distance between bracing wall shall be 9000mm for Wind Classifications up to N2

58

59

60

61

62

63

64

65

66

67

68

69

70 Plan & Prepare For Wall Framing Stress Grading of Individual Wall Frame Members Seasoned Or Unseasoned

71 Stress Grading Refers to the Timbers Strength Timber must be able to withstand stress loads placed on them. Overloading may cause straining or failure 3 types of stress Compressive Tensile Shear Note Torsional Stress is not discussed

72

73

74 Stress Grading Members Sizes will be determined for span tables Generally for Residential Construction sizes will not be specified by designers Why? Architect will not want to take responsibility Engineer will want to charge extra to do this and Why would a client want to pay for something that he can get done for nothing

75 Stress Grading Why are members generally specified on Commercial projects AS 1684.2 Residential Timber Framed Construction Guide

76

77 AS 1684.2 Limitations 1.4.4 The Maximum number of storey's of timber shall not exceed 2 1.4.5 The maximum width of a building shall 16 000mm, Note, if you use AS1684.2 simplified max width = 12 000mm 1.4.6 The maximum wall height shall be 3000mm excluding gable ends 1.4.7 The maximum roof pitch shall be 35 degrees

78

79 Structural pine grading A3P has announced that it will not proceed with the introduction of Structural Pine (SP) grading as previously planned. Continuing contact with A3P members, timber merchants, truss and frame fabricators, designers and specifiers has indicated the introduction cannot be achieved without major disruption and unacceptable burden to industry.

80 Ordering Timber Timber is ordered in lineal meters may be priced in cubic meters Increments of 300mm Lengths over 3600mm are charged at higher rate Timber should be ordered as required - avoid unnecessary exposure to weather - affecting cash flows - theft - storage

81 Material Storage Timber should be stored on gluts This allows for airflow Care should be taken in stack sizes Stacks can be strapped for safety

82 Storage of Materials Timber should be stored as close as possible to work area

83

84

85

86

87

88

89 What is a Concentrated Load ?

90

91

92 Frame Construction Plates The size of plates will depend on 1. Floor Joist Spacing 2. Rafter / Truss Spacing 3. Stud Spacing 4. Single or Double Storey 5. Stress Grade of Timber 6. Roof Load Width ?

93 Roof Load Width (RLW)

94 Plates Seasoned timbers are dressed therefore trenching not required Rough Sawn Timbers such as Oregon, Hardwood require trenching. Housing of plates for studs provides a constant thickness Trenching keeps Top & Bottom plates parallel Restrains Unseasoned Studs from twisting

95 Trenching usually appox 10 mm Trenching depth is not critical but what is left on is. Top Plates fully supported on masonary walls will be sized based on a 300mm spacing

96

97

98 Top Plates AS 1684.2 cl 6.3.4. states that may be a minimum of 35 mm if 1. not required to resist uplift forces (i.e trusses are nominally fixed and 2. Trusses or Rafters are located directly above studs or within 1.5 times the depth of the plate from the stud.

99 Joining of Plates Where plates are butt jointed they may be joined using a connector plate.

100 Joining of Plates Plates may be Scarfed or Lapped jointed. Theses are time consuming and rarely used

101 Calculate Plate Lengths During Fabrication Top & Bottom Plates are the same length Plates should be as long as possible Consider manpower available to stand frames Remember Top Plate must be continuous

102

103 Studs Stud Sizes are determined by 1.Stress Grade 2.Stud Spacing 3.Rafter/ Truss spacing 4.Wall Height 5.Roof Load Width 6.AS 1684.2 tables only specify 450mm or 600mm spacing. These are the most common spacing's

104 Stud Spacing Stud Spacing Determined by 1.Stress Grade 2.Stud Spacing 3.Rafter/ Truss spacing 4.Wall Height 5.Roof Load Width and 6.If applicable External Sheeting Joints (ie Blue Board etc)

105 Studs Not all external sheeting require critical stud placement Check with manufactures manual as to requirements Generally studs should be aligned with the internal face.

106 Harditek (Blue Board)

107 Studs Stud sizes are determined from tables in AS 1684.2

108

109 Calculating Stud Length Finished Floor to Ceiling govern stud length Minimum Habitable Room is 2400mm Clear Floor Finishes 1. Carpet 20mm 2. Timber Flooring 40mm (Depending on Batten) Ceilings 1. 10mm Plasterboard 2. 13mm Plasterboard

110 Calculating Stud Length Double Storey building may have FFL (Finished Floor Level). Allowance must be made for structural members Most Importantly Determine if there are any height restrictions Type of Roof Will affect Stud Heights

111 Top & Bottom Plates = 90 x 45 F5 Step 1 – Determine Floor & Ceiling Floor Carpet = 20mm Ceiling Gyprock = 13mm Step 2 – Calculate Stud Length Minimum Clearance = 2400mm Plus Flooring = 20mm Plus Ceiling = 20mm Wall Height = 2440mm less Wall Plates = 90mm Stud Length = 2350mm

112 Ground Floor First Floor Ground Fl Finish = Timber (40mm) First Floor = Carpet (20mm) Upper Level Joists = 200 x 50 F5 Top & Bottom Plates = 90 x 45 Step 1- Determine SFL (Structural Floor Level) SFL First Floor = 28.950 (FFL First Fl) -20 (Carpet) SFL= 28.930 SFL Ground Fl = 26.200 (FFL Gnd) - 40 (Timber) SFL = 26.160 Step 2 – Calculate Height Difference SFL First Floor = 28.930 – SFL Ground Fl = 26.180 Height Difference = 2.750

113 Step 3 – Structural Elements Height Diff = 2.750 Less Flooring = 0.017 Less Floor Joist = 0.200 Less T & B Plate = 0.090 Stud Length = 2.443 Ground Floor First Floor

114 Carpet Both Floors (20mm) Ceilings 10mm Plasterboard (Allow 20mm) Dimensions are clear measurements Lower level plates Upper Level Plates Bottom Plate = 90 x 35 F5Bottom Plate = 90 x 45 F5 Top Plate = 90 x 45 F5Top Plate = 90 x 70 F5

115 Straightening of Studs

116

117 Calculating Door Heights On Concrete Slab Using a standard 2040mm x 820mm Allow 22mm for Carpet (17mm + 5mm) 2040 mm Door Height 2mm Clearance between Door & Jamb 20mm for Jamb 10mm Clearance between Jamb & Head 15mm Clearance between Jamb & Lintel Total = 2094mm Say 2100mm

118 Calculation of Door Width

119 Calculation of Window Check with manufacturer if windows are not on site Generally at same height of doors Check on elevations for window heights 15mm Clearance between Jamb & Lintel Allow 10mm under sill

120 Window Width Care should be taken when setting out to brick bond! Client may want window to line up with internal fitting Client may want window dead center of room

121

122

123

124 Lintels

125

126

127

128

129 Construct Wall Frames Number Wall Frames Clock Wise Direction Internal Walls Left to Right Top To Bottom

130 Setting Out Plates Confirm Dimensions of Slab/ Subfloor Select Suitable Timber & Cut to Length Tack Together Mark Appropriate ID Number on Plate Mark Required Studs – In Following Order End Studs Wall Intersections

131 Setting Out Plates If required prepare a storey rod with the appropriate markings (ie Horizontal & Vertical Bond) Set out position of window and doors studs remembering to allow for required jamb studs If required adjust position to match brickbond Set out Common Studs, Jack Studs at required spacing

132 Preparing Studs Use Storey Rod (Pattern Stud) to cut required studs Mark and check out window and door studs

133 Fixing Wall Frames To Floors AS 1684.2

134 Wall Frame Assembly What are Advantages & Disadvantages of Prefabricated Wall Frames?

135 Assembling Wall Frames

136

137

138

139

140

141 Frame Erection

142

143

144

145

146 Nominal Fixings For Bottom Plates AS 1684.2

147

148

149

150

151

152 Bracing


Download ppt "BCGCA3004B Construct Wall Framing. Wall Framing Building Code of Australia states that."