1 Irreversible Flow from Turbine Exit to Condenser
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Irreversibilities due to Closed Cycle Policy …..

2 The Last Stage of LP Turbine

3 First Stage of A Turbine : Governing Stage
A governing stage is the first stage in a turbine with nozzle steam distribution. The principal design feature of a governing stage is that its degree of partiality changes with variations of flow rate through the turbine. The nozzles of a governing stages are combined into groups, each of them being supplied with steam from a separate governing valve. A governing stage is separated by a spacious chamber from the subsequent non-controlled stages. Governing stages may be of a single-row or two-row type. Single row impulse governing stage is employed for an enthalpy drop of kJ/kg. Two row governing stages are used when enthalpy drop is high, 100 – 250 kJ/kg.

4 Governing Stage

5 Selection of Enthalpy Drop & Type of Governing stage
The enthalpy drop & type of governing stages are selected by considering the probable effect of the governing stage on the design and efficiency of the turbine. Higher the number of governing stages, lower will be the number of other stages. A high enthalpy drop in governing stage ensures a lower temperature of steam in its chamber and permits application of less expensive materials. In high capacity steam turbines, a single-row governing stages are preferred, since the advantages of elevated enthalpy drop are justified economically. The efficiency of governing stages,

6 Steam Path in Non-Controlled Stages
Estimate approximate mass flow rate of steam by assuming an overall turbine internal efficiency of 0.85. Calculate flow through the condenser, using optimum of number of FWHs. (Using Cycle Calculations). Calculate Modified Efficiency of Low volume and intermediate volume stages. For a group of stages between two successive FWHs. Average density is calculated as

7 The efficiency of groups of very high volume stages:
While designing the steam path, it is essential to consider the pressure losses in the following: Pressure loss in reheater: 0.1 prh. Pressure loss in connecting pipes between turbine cylinders:0.2ppipe.

8 Internal Reheating due to Irreversibilities
3 Governing group 4Is 4Ia Group 1 Macro available enthalpy: 4IIs 4IIa Group 2 4IIIs 4IIIa Group 3 4IVs T 4IVa Group 4 4Vs 4Va Group 5 4VIs 4VIa Micro available enthalpy: 4s s

9 Macro available enthalpy:
Micro available enthalpy: Reheat Factor:

10 Internal Reheating due to Irreversibilities : HP
22.33 MPa,3379.0 3 Governing stage 4Is 4Ia 15.74 MPa, k J/kg Pho=5 % Stage 1 4IIs 4IIa 13.77 MPa, k J/kg Pho=19.5% Stage 2 4IIIs 4IIIa 12.12 MPa, k J/kg Stage 3 Pho=21% 4IVs 4IVa 10.56 MPa, k J/kg T Stage 4 Pho=22% 4Vs 4Va 9.2 MPa, k J/kg Stage 5 Pho=23.5% 4VIs 4VIa 7.94 MPa, k J/kg Stage 6 Pho=25% 4VIIa 6.9 MPa, k J/kg Stage 7 4VIIIa 5.95 MPa, k J/kg Pho=30% Stage 8 4IXa 4s Pho=32% s Pho=35% 5.17 MPa, k J/kg

11 Cumulative Losses for All Stages : 500 MW

12 Definition of Efficiency
Relative blade efficiency is calculated as: Internal Relative Efficiency is calculated as:

13 Blade Efficiency & Internal Relative Efficiency: 800 MW

14 LP Turbine Exhaust System
In a condensing steam turbine, the low-pressure exhaust hood, consisting of a diffuser and a collector or volute!, connects the last stage turbine and the condenser. The function of the hood is to transfer the turbine leaving kinetic energy to potential energy while guiding the flow from the turbine exit plane to the condenser. Most of exhaust hoods discharge towards the downward condenser. Flow inside the hood therefore must turn about 90 deg from the axial direction to the radial direction before exhausting into the condenser. The 90-deg turning results in vortical flow in the upper half part of the collector and also high losses. The exhaust hood is one of the few steam turbine components that has the considerable aerodynamic losses. It is a challenge for engineers to operate a hood with high pressure recovery and low total pressure loss in a compact axial length.

15 Exhaust Hood

16 Exhaust Diffuser For L P Turbine

17 Steam Turbine Exhaust Size Selection
The steam leaving the last stage of a condensing steam turbine can carry considerably useful power to the condenser as kinetic energy. The turbine performance analysis needs to identify an exhaust area for a particular load that provides a balance between exhaust loss and capital investment in turbine equipment.

18 Path Lines in Exhaust Hood

19 Exhaust Losses Exhaust losses are losses which occur between last stage of turbine and condenser. Exhaust losses made up of four components: Actual leaving losses Gross hood loss Annulus restriction loss Turn up loss

20 Residual velocity loss
Steam leaving the last stage of the turbine has certain velocity, which represent the amount of kinetic energy that cannot be imparted to the turbine shaft and thus it is wasted Exhaust end loss Exhaust end loss occur between the last stage of low pressure turbine and condenser inlet. Exhaust loss depends on the absolute steam velocity. Turbine Exhaust end loss = Expansion-line -end point - Used energy at end point.

21 Typical exhaust loss curve showing distribution of component loss
Condenser flow rate Percentage of Moisture at the Expansion line end point SP.Volume Annulus restriction loss Annulus velocity (m/s) Annulus area Total Exhaust Loss 50 Turn-up loss 40 Gross hood loss Exhaust Loss, kJ/kg of dry flow 30 20 Actual leaving loss 10 120 150 180 240 300 360 Annulus Velocity (m/s)

22 Optimal Design of Exhaust Hood

23

24 Performance Analysis of Power Plant Condensers
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi A Device Which makes Power Plant A True Cycle.. A Device Which set the limit on minimum cycle pressure…..

25 T-S Diagram : Rankine Cycle with FWHs.

26 A Device to Convert Dead Steam into Live Water
Water ready to take Rebirth

27 Steam Condenser Steam condenser is a closed space into which steam exits the turbine and is forced to give up its latent heat of vaporization. It is a necessary component of a steam power plant because of two reasons. It converts dead steam into live feed water. It lowers the cost of supply of cleaning and treating of working fluid. It is far easier to pump a liquid than a steam. It increases the efficiency of the cycle by allowing the plant to operate on largest possible temperature difference between source and sink. The steam’s latent heat of condensation is passed to the water flowing through the tubes of condenser. After steam condenses, the saturated water continues to transfer heat to cooling water as it falls to the bottom of the condenser called, hotwell. The difference between saturation temperature corresponding to condenser vaccum and temperature of condensate in hotwell is called condensate depression.

28

29

30 Two-Pass Surface Condenser

31 Layouts of A Condenser

32 Layouts of A Condenser

33 An Integral Steam Turbine and Condenser System