Download presentation
1
MSD-920-2 and MSD-970-1 Automatic Battery Test Systems
2
Solution to Battery Servicing National Stock Number 6130-01-508-3397
MSD-970-1 Solution to Battery Servicing National Stock Number
3
Solution to Portable Battery
MSD-920-2 Solution to Portable Battery Servicing National Stock Number In Process
4
Ampere Hour Capacity Test
MSD & MSD Features Programmed Battery Profiles Selectable Stored Battery Profiles Store Capacity Up to 80 Profiles Up to 10 Steps Per Battery Profile Constant Current Charging Constant Voltage Charging Constant Current Discharging Open Circuit Stand Ampere Hour Capacity Test
5
MSD-970-1 and MSD-920-2 Features
Profile History Collection Tests Any Secondary Battery Chemistry PC Interface for Serial Data Collection User Interface via LCD and 16 Key Keypad Pause / Resume Function NiCad Beep Function Profile Completion Beep Function Minimized Alignment and Adjustment Process Modified Step Execution (i.e. Boost Charge) Reversed Battery Protection
6
Input Power Dimensions :12 5/8” x 21” x 20” Weight: 103 lbs.
MSD Specifications Input Power 240 Vac, Single Phase, 60 Hz 120 Vac, Single Phase, 60 Hz Dimensions :12 5/8” x 21” x 20” Power Cord Adds 2” to the Depth Weight: 103 lbs.
7
Constant Current Charge (0.02 - 70 Amps)
MSD Specifications Constant Current Charge ( Amps) Constant Potential Charge ( Volts) Charge Termination Can Be By: End of Charge Battery Voltage End of Charge Battery Current Battery Temperature Rise Time Negative Voltage Slope Sensing
8
Constant Current Discharge (0.02 - 70 Amps)
MSD Specifications Constant Current Discharge ( Amps) Discharge Termination Can Be By: End of Discharge Voltage Battery Temperature Rise Time Open Circuit Stand Termination (Time) Active Temperature Compensation
9
Input Power Dimensions: 9” x 23” x 14” Weight: 47 lbs.
MSD Specifications Input Power 240 Vac, Single Phase, 60 Hz 120 Vac, Single Phase, 60 Hz Dimensions: 9” x 23” x 14” Weight: 47 lbs.
10
Constant Current Charge (0.02 - 25 Amps)
MSD Specifications Constant Current Charge ( Amps) Constant Potential Charge ( Volts) Charge Termination Can Be By: End of Charge Battery Voltage End of Charge Battery Current Battery Temperature Rise Elapsed Time Negative Voltage Slope Sensing
11
Constant Current Discharge (0.02 - 50 Amps)
MSD Specifications Constant Current Discharge ( Amps) Discharge Termination Can Be By: End of Discharge Voltage Battery Temperature Rise Elapsed Time Open Circuit Stand Termination (Time) Active Temperature Compensation
12
MSD-970-1 and MSD-920-2 Monitored Parameters
Profile Statistics Elapsed Time for Step and Profile Step Number / Step Type Charge Current Charge Voltage Temperature Ampere Hours Charge / Discharge / Recharge
13
EaglePicher Technologies, LLC 3220 Industrial Road Joplin, MO. 64801
Contact Information Greg Miller EaglePicher Technologies, LLC 3220 Industrial Road Joplin, MO Voice: (417) Fax: (417)